IS230PCAAH1A Core Analog Module – GE Energy Mark VIe Series
Technical Specifications
- Brand: GE Energy
- Model: IS230PCAAH1A
- Series: Mark VIe
- Category: Core Analog Module
- Product Type: Core Analog Module
- Terminal Board: TCAS
- Optional Terminal Board: TCAT
- Signal Type: Input and Output Signals
- Dimensions: 17.71 × 13.77 × 7.87 cm
- Operating Temperature: -30 to +65°C
- Mounting Strategy: Non DIN-Rail Modular
- DIN Rail Installation Hardware: Not Included
- Country of Manufacture: United States (USA)
Supported I/O Types
- Thermocouple inputs for high-temperature measurement
- Analog 4-20 mA current loop inputs and outputs
- Seismic inputs for vibration monitoring
- LVDT excitation and inputs for position sensing
- Pulse rate inputs for speed and frequency measurement
- Servo coil driver outputs for actuator control
- +/- 12 V power output for compatible field devices
Functional Description
- System Modes: The module supports simplex, dual, and TMR (Triple Modular Redundant) configurations. A single TCAT terminal board distributes signal inputs to one, two, or three PCAA modules.
- Power and Grounding Extensions: An adjacent JGPA board's shield ground and 24 V field power terminals supplement the terminals on the PCAA and TCAT.
- Internal Board Architecture: The module includes a BPPB processor board, two application I/O boards, and a TCAS terminal board.
- Serviceability: The entire module is the least replaceable unit (LRU). No support is provided to diagnose or replace individual internal boards.
- Connectivity: The module uses a 28 V dc power connector, two RJ45 Ethernet connectors, and 120 Euro-style box terminals for field device I/O.
- Power to JGPA: Power reaches a JGPA board through connector P4.
- TCAT Connection: Two 68-pin cables on connectors P1 and P2 connect the module to the TCAT.
- Signal Routing: PCAA signals divide into two groups. The TCAT routes signal inputs that can fan from a single input into a single, dual, or TMR PCAA module. Signals dedicated to one PCAA module wire directly to terminals. PCAA can operate without TCAT when fanned inputs are not required.
Processor Features
- Two fully independent 10/100 Ethernet ports with connectors
- Hardware watchdog timer and reset circuit
- Internal temperature sensor for thermal monitoring
- Status-indicating LEDs for quick diagnostics
- Electronic ID and the ability to read IDs on other boards
- Soft start and current limiter on the input power connector
- Local power supplies with sequencing and monitoring
Power Management
- Inrush Current Control: The 28 V input circuit includes power management. A soft start function controls current inrush during power application.
- Disturbance Prevention: After power application, a fast current limit function prevents a power disturbance from propagating back onto the 28 V power system.
- PWR Indicator: The green PWR indicator illuminates when power is present and functioning properly. If the current limit function is enabled, the indicator stays illuminated until the problem is resolved
FAQ
-
Q: What is the model number of this GE Energy module?
A: The model number is IS230PCAAH1A, and it belongs to the Mark VIe series. -
Q: What does this module do in a Mark VIe system?
A: It provides a large portion of the analog signal I/O required to operate a gas turbine. -
Q: What I/O types does the module support?
A: It supports thermocouples, 4-20 mA current loops, seismic inputs, LVDT excitation and inputs, pulse rate inputs, and servo coil outputs. -
Q: Which system modes can use this module?
A: The module supports simplex, dual, and TMR (Triple Modular Redundant) system configurations. -
Q: What is the operating temperature range?
A: The module operates from -30 to +65°C. -
Q: What terminal board does this module use?
A: It uses a TCAS terminal board and supports optional TCAT terminal boards. -
Q: How many terminals does the PCAA module have?
A: The module features 120 Euro-style pluggable box terminals for field device I/O. -
Q: How does the module connect to the TCAT board?
A: Two 68-pin cables on connectors P1 and P2 connect the module to the TCAT. -
Q: What does the green PWR indicator mean?
A: The green PWR indicator illuminates when power is present and functioning properly. -
Q: What are the dimensions of this module?
A: The module measures 17.71 × 13.77 × 7.87 cm. -
Q: Is DIN rail installation hardware included?
A: No, DIN rail installation hardware is not included with this module. -
Q: Is this item in stock, and how fast do you ship?
A: Yes, we keep it in stock and ship within 5 days using FedEx, UPS, or DHL.
Contact Information Inquiries: sales@nex-auto.com or +86 153 9242 9628
Partner NexAuto Technology Limited: https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.