150-F108NBRB SMC Flex Smart Motor Controller – 108 A Soft Starter by Allen-Bradley
Technical Specifications
- Brand: Allen-Bradley
- Model: 150-F108NBRB
- Series: SMC Flex
- Category: Soft Starter / Smart Motor Controller
- Controller Rating: 108 A, 20–75 Hp @ 460V AC
- Rated Operating Voltage (Ue): 200 V
- Rated Control Supply Voltage: 24 V AC at 50/60 Hz; 24 V DC
- Overload Current (Line Connected): 27 A
- Overload Current (Delta Connected): 47 A
- Controller Type: Soft starter
- Control Options: Pump control
- Trip Classes: 10, 15, 20, and 30
- Trip Current Rating: 117% of motor FLC
- Transformer Control Module: 75VA @ 100–240V AC (-15%, +10%)
- Heatsink Fan Rating: 20VA @ 110/120V AC or 220/240V AC
- DV/DT Protection: RC snubber network for power circuit
- Repetitive Peak Inverse Voltage: 1400V per UL/CSA/NEMA
- Operating Frequency: 50/60 Hz for power circuit
- Line Connected Motor Power (Max): 90 kW @ 690V/Y AC, 50 Hz, 3-phase
- Delta Connected Motor Power (Max): 90 kW @ 400/415V AC, 50 Hz, 3-phase
- Rated Impulse Voltage: 6000V per IEC
- Dielectric Withstand: 2500V per IEC
- Line Connected Motor Current: 27–108 A @ 600/Y/690V AC, 3-phase
- Delta Connected Motor Current: 47–187 A @ 500/575V AC, 3-phase
- Transient Protection: Metal oxide varistors: 220 J (optional)
- Insulation Voltage: Rated 500V per IEC
- Rated Operational Voltage: 200–480V AC (-15%, +10%) per UL/CSA/NEMA
- Input OFF-State Current: <10 mA AC, <3 mA DC for control circuit
- Short-Circuit Protection Device List: Standard fuse, circuit breaker, and high capacity time delay class CC/J/L
- Number of Contacts: 1 for auxiliary contacts
- High Capacity Available Fault Current (Max): 70kA @ 600V, maximum current 300 A time delay Class J or Class L fuse for inside delta connected motors
- Type of Current: AC for auxiliary contacts
- Conventional Thermal Current (Ith): AC/DC: 5 A for auxiliary contacts
- Type of Control Circuit: Electromagnetic relay for auxiliary contacts
- Type of Contacts: Programmable NO/NC for auxiliary contacts
- Utilization Category: MG 1 per UL/CSA/NEMA for power circuit
- Standard Controller Feature: Status indication: stopped, starting, stopping, at speed, alarm, and fault
- Standard Available Fault Current (Max): 70kA @ 690V for maximum FLC
- Optional Controller Feature: SMB smart motor braking control – provides motor braking without additional equipment; braking current adjustable from 0–400% of motor full-load current rating
- Rated Control Supply Voltage at DC: 24 V
- Integrated Motor Overload Protection: True
- Short Circuit Protection Device Performance (SCPD) Type: Type 1
- Number of Sensors (Max): 6 for PTC input ratings
- Inrush Current Control Module: 5A @ 24V DC (-15%, +10%)
- Voltage at PTC Terminals (RPTC = open), Max: 30V
- Transient Watts Control Module: 60 W @ 24V DC (-15%, +10%)
- Steady State Watts Control Module: 24 W @ 24V DC (-15%, +10%)
- Voltage at PTC Terminals (RPTC = 4 kΩ), Max: <7.5 V
- Response Time: 800 ms for PTC input ratings
- Inrush Time Control Module: 250 ms @ 24V DC (-15%, +10%)
- Transient Time Control Module: 500 ms @ 24V DC (-15%, +10%)
- Cold Resistance of PTC Sensor Chain (Max): 1500 Ω
- Tachometer Input: 0–5V DC @ 4.5V DC = 100% Speed
- Allen Bradley Power Supply Control Module (Min): 1606-XLP50E @ 24V DC (-15%, +10%)
- Short Circuit Trip Resistance: 25 Ω ± 10 Ω
- Response Resistance: 3400 Ω ± 150 Ω
- Reset Resistance: 1600 Ω ± 100 Ω
- Input OFF-State Voltage (Max): 50V AC @ 10V DC/12V AC for control circuit
- Input ON-State Voltage (Min): 85V AC @ 19.2V DC/20.4V AC for control circuit
- Rated Operational Current: 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
- Input ON-State Current: 20mA @ 120V AC / 40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit
- Contact Type: Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3), and 33/34 (Aux #4)
- Steady State Heat Dissipation with Control and Fan Power: 91 W
- Storage and Transportation Temperature: -20 °C
- Humidity: 5–95% (noncondensing)
- Operating Temperature: Open: -5 to 50 °C (23 to 122 °F)
- Protection Against Electrical Shock: IP2X (with terminal covers) per IEC for power circuit
- EMC Emission Levels: Radiated emission: Class A
- EMC Immunity Levels: Surge transient: per EN/IEC 60947-4-2
- Altitude: 2000 m
- Pollution Degree: 2
- Weight: 15 kg
- Shock: Opsal: 5.5 G
- Width: 196.4 mm (7.74 in)
- Depth: 212.2 mm (8.35 in)
- Height: 443.7 mm (17.47 in)
- Power Pole Construction: Heatsink hockey puck thyristor modular design
- Vibration: Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
- Make: 3600VA for auxiliary contacts
- Break: 360VA for auxiliary contacts
- Internal Bypass: True
- Function: Single direction
- Power Terminal Markings: NEMA, CENELEC EN50 012
- Control Terminals: Clamping yoke connection, M3 screw clamp
- Line/Load Side Power Terminals: One M10 x 1.5 diam hole per power pole
- Number of Poles: 3
- Enclosure: Open type
- Control Modules Construction: Thermoset and thermoplastic moldings
- Metal Parts Construction: Plated brass, copper, or painted steel
Key Performance Characteristics
- Overload current for line connected devices: 27 A
- Overload current for delta connected devices: 47 A
- Trip classes: 10, 15, 20, and 30
- Trip current rating: 117% of motor FLC
- Integrated motor overload protection: True
- Internal bypass: True
FAQ
-
Q: What is the current rating of the 150-F108NBRB?
A: The controller handles 108 A for line connected motors and 47 A for delta connected motors. -
Q: Which trip classes does this soft starter support?
A: It supports trip classes 10, 15, 20, and 30. -
Q: What is the operating temperature range?
A: The open-type controller operates from -5 to 50 °C (23 to 122 °F). -
Q: Does this model include integrated motor overload protection?
A: Yes, the 150-F108NBRB includes integrated motor overload protection. -
Q: What is the rated control supply voltage?
A: It accepts 24 V AC at 50/60 Hz and 24 V DC. -
Q: How many auxiliary contacts does it provide?
A: It provides one auxiliary contact with programmable NO/NC configuration. -
Q: What shipping methods do you use?
A: We ship via FedEx, UPS, and DHL. -
Q: What is the return policy?
A: We support returns within 30 days.
Contact Information
- Inquiries: sales@nex-auto.com
- WhatsApp: +86 153 9242 9628
- Partner: NexAuto Technology Limited
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.