Technical Specifications

  • Brand: Bently Nevada
  • Model: 9200-09-01-02-00
  • Category: Two-Wire Velocity Seismoprobe Transducer
  • Sensitivity: 20 mV/mm/s (500 mV/in/s), ±5% when properly terminated and oriented at the calibration angle
  • Minimum Operating Frequency: 15 Hz (900 cpm)
  • Velocity Range: 25 mm/s (1 in/s) at +22°C casing vibration at 100 Hz with a 10 kΩ load
  • Dynamic Operating Range: 2.54 mm (0.100 in) peak to peak maximum displacement
  • Coil Resistance: 1.25 kΩ ±5%
  • Locked Coil Inductance: 125 mH typical
  • Load: 10 kΩ terminal "A" to "B", output taken across pins "A" and "B"
  • Temperature Coefficient: 0.2%/°C
  • Operating and Storage Temperature: -29°C to +121°C (-20°F to +250°F) for 9200; -29°C to +204°C (-20°F to +400°F) for 74712
  • Relative Humidity: To 95%, noncondensing; 100%, non-submerged when ordered with integral cable
  • Environment: Dust and moisture resistant
  • Case and Adapter Material: Anodized aluminum A204
  • Gasket Material: Neoprene (9200)
  • Height: 102 mm (4 in) typical, depending on connector option
  • Diameter: 41 mm (1.6 in) typical
  • Weight: 300 grams (10.5 ounces) typical
  • Connector Option: 01 = Top Mount (no cable)
  • Mounting Base Option: 02 = Circular; 1/4-28 UNF stud
  • Agency Approval Option: 00 = No approvals required
  • Compliance: FCC Part 15; EMC Directive 2014/30/EU; EN 61326-1; RoHS Directive 2011/65/EU
  • Hazardous Area Approvals: cNRTLus Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III; Class I, Zone 2: A/Ex nA IIC T6 Gc; Class I, Zone 2: A/Ex ec IIC T6 Gc; T6 @ Ta = -20°C to +40°C; ATEX/IECEx II 1 G Ex ia IIC T6 Ga; II 3 G Ex nA IIC T6 Gc; II 3 G Ex ec IIC T6 Gc; T6 @ Ta = -20°C to +40°C

Frequently Asked Questions

  • Q: What is the sensitivity of the 9200-09-01-02-00?
    A: The sensitivity is 20 mV/mm/s (500 mV/in/s) with ±5% accuracy when properly terminated and oriented at the calibration angle.
  • Q: What is the minimum operating frequency?
    A: The minimum operating frequency is 15 Hz (900 cpm).
  • Q: What is the velocity range?
    A: The velocity range is 25 mm/s (1 in/s) at +22°C casing vibration at 100 Hz with a 10 kΩ load.
  • Q: What is the operating temperature range?
    A: The 9200 operates from -29°C to +121°C (-20°F to +250°F). The 74712 operates from -29°C to +204°C (-20°F to +400°F).
  • Q: What is the coil resistance?
    A: The coil resistance is 1.25 kΩ ±5%.
  • Q: What is the locked coil inductance?
    A: The locked coil inductance is 125 mH typical.
  • Q: What is the load requirement?
    A: The load is 10 kΩ terminal "A" to "B", with output taken across pins "A" and "B".
  • Q: What is the dynamic operating range?
    A: The dynamic operating range is 2.54 mm (0.100 in) peak to peak maximum displacement.
  • Q: What is the temperature coefficient?
    A: The temperature coefficient is 0.2%/°C.
  • Q: What is the weight of the transducer?
    A: The weight is 300 grams (10.5 ounces) typical.
  • Q: What is the diameter and height?
    A: The diameter is 41 mm (1.6 in) typical. The height is 102 mm (4 in) typical, depending on connector option.
  • Q: What materials make up the case and gasket?
    A: The case and adapter use anodized aluminum A204. The gasket uses neoprene for the 9200.
  • Q: What connector and mounting options does this model have?
    A: Connector option 01 is top mount (no cable). Mounting base option 02 is circular with a 1/4-28 UNF stud.
  • Q: What agency approvals does this model carry?
    A: Agency approval option 00 means no approvals required. The product also complies with FCC Part 15, EMC Directive 2014/30/EU, EN 61326-1, and RoHS Directive 2011/65/EU. Hazardous area approvals include cNRTLus, ATEX, and IECEx.
  • Q: Is this product new and original?
    A: Yes, this product is new and original in factory packing. We have it in stock.
  • Q: How fast do you ship?
    A: We ship within 5 days. We use FedEx, UPS, and DHL.
  • Q: What is your return policy?
    A: We support 30-day returns.

Contact Information

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most