Honeywell TC-IDX161 16-Point Diagnostic Discrete Input Module
1
/
of
3
Honeywell TC-IDX161 16-Point Diagnostic Discrete Input Module
No reviews
In stock (16 units), ready to be shipped
-
Vendor:
Honeywell
-
Type:
Discrete Input Module
-
Country of Origin:
USA
-
Dimensions:
17*35*5cm
- Weight:
500 g
- Tags: Discrete input module
Honeywell TC-IDX161 10-30 VDC, 16-Point Diagnostic Discrete Input Module
Key Technical Specifications
- Brand: Honeywell
- Model: TC-IDX161
- Category: Diagnostic Discrete Input Module
- Number of Points: 16 points with 4 points per common
- Nominal Input Voltage: 24 VDC
- On-State Voltage Range: 10–30 VDC
- Input Compatibility: IEC Type 1+
- Off-State Voltage (Maximum): 5 VDC
- On-State Current (Minimum): 2.0 mA at 10 VDC
- Off-State Current (Maximum): 1.5 mA
- Input Impedance (Maximum): 3.7 KΩ at 10 VDC
- Short/Inrush Current: 250 mA peak, decaying to less than 37% in 22 ms without activation
- Power Dissipation: 5.8 W maximum
- Isolation Voltage – Channel to Channel: 100% tested at 2546 VDC for 1 second
- Isolation Voltage – User to System: 100% tested at 2546 VDC for 1 second
- Connection Terminal Blocks: TC-TBCH, 36-position terminal block
Diagnostic Functions and Leakage Resistor Configuration
- The module offers two software configurable diagnostic functions: open wire detection and change of state monitoring.
- Open wire diagnostics help you find broken field wiring before a machine stops.
- Change of state diagnostics track unexpected input transitions for faster troubleshooting.
- Current leakage in the off state stays at 1.21 mA maximum for dependable detection.
- Use the formula Rleak Maximum = (P/S Voltage - 4.6 VDC) / 1.21 mA to size the leakage resistor.
- Use the formula Rleak Minimum = (P/S Voltage – 5 VDC) / 1.5 mA to set the lower resistor bound.
- For a 12 VDC power supply at +/-5%, choose a 5.23 KΩ, ¼ W, 2% leakage resistor.
- For a 24 VDC power supply at +/-5%, choose a 14.3 KΩ, ¼ W, 2% leakage resistor.
- P/S refers to the field side power supply in these calculations.
Input Signal Delay Settings
- Off-to-on delay is programmable at 0 ms, 1 ms, or 2 ms.
- On-to-off delay is programmable at 0 ms, 1 ms, 9 ms, or 18 ms.
- These delay options let you filter noise and match fast or slow machine cycles.
- Shorter delays suit high-speed sorting and registration tasks.
- Longer delays reduce false triggers from contact bounce and electrical noise.
Installation Guide
- Mount the TC-IDX161 on a compatible Honeywell backplane or chassis.
- Use the TC-TBCH 36-position terminal block for all field wiring connections.
- Wire each group of four input points to its common terminal.
- Confirm the on-state voltage range of 10–30 VDC before you power up field devices.
- Add the correct leakage resistor when you enable open wire diagnostics.
- Set the programmable input delay times to match your control loop needs.
- Keep the off-state voltage below 5 VDC to prevent unintended channel activation.
- Verify isolation integrity with a 2546 VDC test after installation if required.
Package List
- 1 x Honeywell TC-IDX161 10-30 VDC 16-Point Diagnostic Discrete Input Module
- 1 x TC-TBCH 36-position terminal block
- 1 x Quick start guide
- Protective packaging for safe transport
Shipping and Support
- We ship via FedEx, UPS, and DHL to most international destinations.
- Orders leave our warehouse within 5 days after payment confirmation.
- We keep this module in stock as brand new original stock.
- We support 30-day returns for eligible orders.
- Contact us for bulk orders or special logistics requests.
FAQ
-
Q: What diagnostic functions does the Honeywell TC-IDX161 support?
A: It supports open wire detection and change of state monitoring, both software configurable. -
Q: How many points does this module have and how are they grouped?
A: It has 16 points arranged as 4 points per common. -
Q: What is the off-state leakage current?
A: The off-state current leakage is 1.21 mA maximum. -
Q: What leakage resistor should I use for a 24 VDC supply?
A: Use a 14.3 KΩ, ¼ W, 2% resistor for a 24 VDC +/-5% power supply. -
Q: Can I adjust the input signal delay?
A: Yes, off-to-on delay is 0, 1, or 2 ms, and on-to-off delay is 0, 1, 9, or 18 ms. -
Q: What isolation voltage does the TC-IDX161 provide?
A: Both channel-to-channel and user-to-system isolation are 100% tested at 2546 VDC for 1 second. -
Q: What terminal block does this module use?
A: It uses the TC-TBCH 36-position terminal block. -
Q: Is this module in stock and how fast do you ship?
A: Yes, we have brand new original stock and ship within 5 days via DHL, FedEx, or UPS. -
Q: What is the return policy?
A: We support 30-day returns for eligible orders.
Contact Information
Inquiries: sales@nex-auto.com or +86 153 9242 9628
Partner NexAuto Technology Limited : https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.