Honeywell TC-IDJ161 24 VDC 16-Point Isolated Discrete Input Module
Key Technical Specifications
- Brand: Honeywell
- Model: TC-IDJ161
- Category: Isolated Discrete Input Module
- Number of Points: 16 points with individual isolation
- Nominal Input Voltage: 24 VDC
- On-State Voltage Range: 10–30 VDC
- Input Compatibility: IEC Type 1+
- Short/Inrush Current: 250 mA peak, decaying to less than 37% in 22 ms without activation
- Off-State Voltage (Maximum): 5 VDC
- On-State Current (Minimum): 2.0 mA at 10 VDC
- Off-State Current (Maximum): 1.5 mA
- Input Impedance (Maximum): 31 KΩ at 60 Hz
- Input Delay Time – Off to On: Programmable 1 ms and 2 ms; hardware delay 1 ms maximum plus filter time
- Input Delay Time – On to Off: Programmable 1 ms, 2 ms, 9 ms, and 18 ms; hardware delay 4 ms maximum plus filter time
- Power Dissipation: 5.0 W maximum
- Backplane Current: See Module Power Consumption Data, page 46
- Isolation Voltage – Channel to Channel: 100% tested at 2546 VDC for 1 second
- Isolation Voltage – User to System: 100% tested at 2546 VDC for 1 second
- Connection Terminal Blocks: TC-TBCH, 36-position terminal block
Performance and Environmental Capabilities
- The module handles 16 individually isolated channels, which prevents cross-channel interference.
- It accepts a wide on-state voltage range from 10 VDC to 30 VDC for flexible field wiring.
- The short/inrush current reaches 250 mA peak and decays quickly to below 37% in 22 ms.
- Off-state voltage stays at 5 VDC maximum, so false triggering remains very low.
- Minimum on-state current is only 2.0 mA at 10 VDC, which supports low-power sensors.
- Maximum off-state current is 1.5 mA, keeping leakage under control.
- Input impedance reaches 31 KΩ maximum at 60 Hz for stable AC rejection.
- Programmable delay times let you tune response speed for different machine cycles.
- Power dissipation stays at 5.0 W maximum, which helps with thermal planning.
- Isolation voltage is 100% tested at 2546 VDC for 1 second on both channel-to-channel and user-to-system paths.
Installation Guide
- Mount the TC-IDJ161 on a compatible Honeywell backplane or chassis.
- Use the TC-TBCH 36-position terminal block for field wiring connections.
- Verify that the backplane current stays within the module power consumption data on page 46.
- Wire each input channel according to the 24 VDC nominal voltage and IEC Type 1+ compatibility.
- Check the on-state voltage range of 10–30 VDC before powering up the field devices.
- Set the programmable input delay time to match your control loop requirements.
- Confirm isolation voltage integrity after installation with a 2546 VDC test if needed.
- Keep the off-state voltage below 5 VDC to avoid unintended channel activation.
Package List
- 1 x Honeywell TC-IDJ161 24 VDC 16-Point Isolated Discrete Input Module
- 1 x TC-TBCH 36-position terminal block
- 1 x Quick start guide
- Protective packaging for safe transport
Shipping and Support
- We ship via FedEx, UPS, and DHL to most international destinations.
- Orders leave our warehouse within 5 days after payment confirmation.
- We keep this module in stock as brand new original stock.
- We support 30-day returns for eligible orders.
- Contact us for bulk orders or special logistics requests.
FAQ
-
Q: What is the input voltage range for the Honeywell TC-IDJ161?
A: The on-state voltage range is 10–30 VDC with a nominal input voltage of 24 VDC. -
Q: How many isolated input points does this module offer?
A: It provides 16 individually isolated discrete input points. -
Q: Can I adjust the input delay time?
A: Yes, off-to-on delay is programmable at 1 ms and 2 ms, while on-to-off delay is programmable at 1 ms, 2 ms, 9 ms, and 18 ms. -
Q: What isolation voltage does the TC-IDJ161 support?
A: Both channel-to-channel and user-to-system isolation are 100% tested at 2546 VDC for 1 second. -
Q: What terminal block does this module use?
A: It uses the TC-TBCH 36-position terminal block. -
Q: Is this module in stock and how fast do you ship?
A: Yes, we have brand new original stock and ship within 5 days via DHL, FedEx, or UPS. -
Q: What is the return policy?
A: We support 30-day returns for eligible orders.
Contact Information
Inquiries: sales@nex-auto.com or +86 153 9242 9628
Partner NexAuto Technology Limited : https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.