IS200EPCTG1AAA GE Exciter PT/CT Board – Mark VI & EX2100 Product Introduction
Technical Specifications
- Brand: General Electric (GE)
- Model: IS200EPCTG1AAA
- Category: Exciter PT/CT (EPCT) Terminal Board
- Series: Mark VI Speedtronic / EX2100 excitation system
- Functional Acronym: EPCT
- Revision Total: 3 revisions
- Backwards Compatibility: First two revisions
- Assembly Type: Normal Assembly
- Number of Channels: 6
- Temperature Range: -30 to 65 °C
- Size: 8.6 cm wide × 16.2 cm high
- Country of Manufacture: United States of America
- Front Edge Terminal Strips: One 24-position strip and two 4-position strips
- Rear Edge Connectors: Three vertical pin connectors labeled J315, J305, and J308
- Test Points: 12 test points plus 8 voltage test points (TP1–8) on the isolation transformer secondary side
- On-Board Hardware: One jumper switch, 2 toroidal transformers, 4 frame-mounted transformers, resistors, capacitors, and metal oxide varistors (MOVs)
- Availability: In stock
Functional Overview
- The board handles critical generator voltage and current measurements through isolation transformers.
- It integrates two 3-phase generator potential transformer (PT) voltage inputs.
- It also includes two generator current transformer (CT) inputs with 1 A or 5 A options.
- All isolation transformer output signals travel by cable to the EMIO board.
- The board accepts a single analog input for either voltage or current signals.
- A redundant system can include up to three EPCT boards for robustness.
- Components T1 through T6 denote the voltage and current isolation transformers.
Voltage and Current Measurement Details
- Generator voltages pass from potential transformers through switches to TB1.
- PT inputs run at a nominal 115 V rms with 50/60 Hz frequency.
- These PT inputs carry fuses for protection against electrical anomalies.
- Two isolation transformers perform a three-wire open delta voltage measurement.
- Each transformer converts a 115 V rms input to a 1.533 V rms output.
- Generator current inputs connect to fixed terminal blocks TB2 and TB3.
- Each current transformer offers a 0–1 A rms winding and a 0–5 A rms winding.
- Only one winding wires to the EPCT board at a time.
- Cable lengths from the transformer to the board can reach 1000 ft.
- TB1 stays removable, while TB2 and TB3 remain fixed to prevent CT open circuits.
Test Points and Connector Routing
- Four voltage test points (TP9–12) sit on the generator current isolation transformer secondary side.
- Never ground these test points through the measuring device.
- Eight voltage test points (TP1–8) support diagnostics on the isolation transformer secondary side.
- In a simplex setup, voltage signals travel via J305 to the EMIO board in the M1 controller.
- In redundant configurations, signals distribute to J305, J308, and J315.
- These routes transmit to the M1, M2, and C controllers respectively.
- Three 25-pin sub-D connectors link to the EBKP backplane for data transfer.
Installation Guide
- Review the manuals or data sheets supplied with your OEM purchase before handling.
- Treat the board as static-sensitive and use anti-static protection at all times.
- Confirm the cable length stays within the 1000 ft limit using 12 AWG wire.
- Use wire gauges up to #10 AWG for current transformer cable runs.
- Keep the measuring device isolated from the TP9–12 test points during checks.
- Verify J305, J308, and J315 seating against the EBKP backplane connectors.
Packing List
- One IS200EPCTG1AAA Exciter PT/CT terminal board
- Anti-static protective packaging material
- Original GE manual or data sheet reference where available
- Shipping through FedEx, UPS, or DHL
FAQ
-
Q: What is the condition of this board?
A: We supply brand new original units. -
Q: Do you have stock available?
A: Yes, we hold this item in stock. -
Q: How fast do you ship?
A: We dispatch within 5 days of your order. -
Q: Which logistics partners do you use?
A: We ship through common carriers such as DHL, FedEx, and UPS. -
Q: Can I return the product?
A: Yes, we support returns within 30 days. -
Q: How many revisions does the IS200EPCTG1AAA have?
A: GE released three revisions, and the first two stay backwards-compatible. -
Q: What temperature range does the board support?
A: It operates from -30 to 65 °C. -
Q: How many channels does the board provide?
A: The board provides 6 channels. -
Q: What PT input voltage and frequency does it accept?
A: The PT inputs accept a nominal 115 V rms at 50/60 Hz. -
Q: What CT current options does the board offer?
A: Each current transformer offers 1 A or 5 A rms windings. -
Q: How long can the cables run?
A: Cable lengths can reach 1000 ft using 12 AWG wire. -
Q: Can I ground the TP9–12 test points?
A: No, never ground them through the measuring device. -
Q: How many EPCT boards can a redundant system use?
A: A redundant system can include up to three EPCT boards. -
Q: Where does GE manufacture this board?
A: GE manufactures this board in the United States of America.
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.