Skip to product information
1 of 3

IS200EPCTG1AAA GE Exciter Board Mark VI EX2100

In stock (14 units), ready to be shipped
  • Vendor:

    General Electric

  • Type:

    Terminal Board

  • Country of Origin:

    USA

  • Dimensions:

    30*18*4cm

  • Weight:

    500 g

  • Tags: Terminal board

IS200EPCTG1AAA GE Exciter PT/CT Board – Mark VI & EX2100 Product Introduction

Technical Specifications

  • Brand: General Electric (GE)
  • Model: IS200EPCTG1AAA
  • Category: Exciter PT/CT (EPCT) Terminal Board
  • Series: Mark VI Speedtronic / EX2100 excitation system
  • Functional Acronym: EPCT
  • Revision Total: 3 revisions
  • Backwards Compatibility: First two revisions
  • Assembly Type: Normal Assembly
  • Number of Channels: 6
  • Temperature Range: -30 to 65 °C
  • Size: 8.6 cm wide × 16.2 cm high
  • Country of Manufacture: United States of America
  • Front Edge Terminal Strips: One 24-position strip and two 4-position strips
  • Rear Edge Connectors: Three vertical pin connectors labeled J315, J305, and J308
  • Test Points: 12 test points plus 8 voltage test points (TP1–8) on the isolation transformer secondary side
  • On-Board Hardware: One jumper switch, 2 toroidal transformers, 4 frame-mounted transformers, resistors, capacitors, and metal oxide varistors (MOVs)
  • Availability: In stock

Functional Overview

  • The board handles critical generator voltage and current measurements through isolation transformers.
  • It integrates two 3-phase generator potential transformer (PT) voltage inputs.
  • It also includes two generator current transformer (CT) inputs with 1 A or 5 A options.
  • All isolation transformer output signals travel by cable to the EMIO board.
  • The board accepts a single analog input for either voltage or current signals.
  • A redundant system can include up to three EPCT boards for robustness.
  • Components T1 through T6 denote the voltage and current isolation transformers.

Voltage and Current Measurement Details

  • Generator voltages pass from potential transformers through switches to TB1.
  • PT inputs run at a nominal 115 V rms with 50/60 Hz frequency.
  • These PT inputs carry fuses for protection against electrical anomalies.
  • Two isolation transformers perform a three-wire open delta voltage measurement.
  • Each transformer converts a 115 V rms input to a 1.533 V rms output.
  • Generator current inputs connect to fixed terminal blocks TB2 and TB3.
  • Each current transformer offers a 0–1 A rms winding and a 0–5 A rms winding.
  • Only one winding wires to the EPCT board at a time.
  • Cable lengths from the transformer to the board can reach 1000 ft.
  • TB1 stays removable, while TB2 and TB3 remain fixed to prevent CT open circuits.

Test Points and Connector Routing

  • Four voltage test points (TP9–12) sit on the generator current isolation transformer secondary side.
  • Never ground these test points through the measuring device.
  • Eight voltage test points (TP1–8) support diagnostics on the isolation transformer secondary side.
  • In a simplex setup, voltage signals travel via J305 to the EMIO board in the M1 controller.
  • In redundant configurations, signals distribute to J305, J308, and J315.
  • These routes transmit to the M1, M2, and C controllers respectively.
  • Three 25-pin sub-D connectors link to the EBKP backplane for data transfer.

Installation Guide

  • Review the manuals or data sheets supplied with your OEM purchase before handling.
  • Treat the board as static-sensitive and use anti-static protection at all times.
  • Confirm the cable length stays within the 1000 ft limit using 12 AWG wire.
  • Use wire gauges up to #10 AWG for current transformer cable runs.
  • Keep the measuring device isolated from the TP9–12 test points during checks.
  • Verify J305, J308, and J315 seating against the EBKP backplane connectors.

Packing List

  • One IS200EPCTG1AAA Exciter PT/CT terminal board
  • Anti-static protective packaging material
  • Original GE manual or data sheet reference where available
  • Shipping through FedEx, UPS, or DHL

FAQ

  • Q: What is the condition of this board?
    A: We supply brand new original units.
  • Q: Do you have stock available?
    A: Yes, we hold this item in stock.
  • Q: How fast do you ship?
    A: We dispatch within 5 days of your order.
  • Q: Which logistics partners do you use?
    A: We ship through common carriers such as DHL, FedEx, and UPS.
  • Q: Can I return the product?
    A: Yes, we support returns within 30 days.
  • Q: How many revisions does the IS200EPCTG1AAA have?
    A: GE released three revisions, and the first two stay backwards-compatible.
  • Q: What temperature range does the board support?
    A: It operates from -30 to 65 °C.
  • Q: How many channels does the board provide?
    A: The board provides 6 channels.
  • Q: What PT input voltage and frequency does it accept?
    A: The PT inputs accept a nominal 115 V rms at 50/60 Hz.
  • Q: What CT current options does the board offer?
    A: Each current transformer offers 1 A or 5 A rms windings.
  • Q: How long can the cables run?
    A: Cable lengths can reach 1000 ft using 12 AWG wire.
  • Q: Can I ground the TP9–12 test points?
    A: No, never ground them through the measuring device.
  • Q: How many EPCT boards can a redundant system use?
    A: A redundant system can include up to three EPCT boards.
  • Q: Where does GE manufacture this board?
    A: GE manufactures this board in the United States of America.

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most