Skip to product information
1 of 3

150-F108NBRB Allen-Bradley SMC Flex Soft Starter

In stock (14 units), ready to be shipped
  • Vendor:

    Allen-Bradley

  • Type:

    Smart Motor Controller

  • Country of Origin:

    USA

  • Dimensions:

    56*22*23cm

  • Weight:

    30000 g

  • Tags: Smart motor controller

150-F108NBRB SMC Flex Smart Motor Controller – 108 A Soft Starter by Allen-Bradley

Technical Specifications

  • Brand: Allen-Bradley
  • Model: 150-F108NBRB
  • Series: SMC Flex
  • Category: Soft Starter / Smart Motor Controller
  • Controller Rating: 108 A, 20–75 Hp @ 460V AC
  • Rated Operating Voltage (Ue): 200 V
  • Rated Control Supply Voltage: 24 V AC at 50/60 Hz; 24 V DC
  • Overload Current (Line Connected): 27 A
  • Overload Current (Delta Connected): 47 A
  • Controller Type: Soft starter
  • Control Options: Pump control
  • Trip Classes: 10, 15, 20, and 30
  • Trip Current Rating: 117% of motor FLC
  • Transformer Control Module: 75VA @ 100–240V AC (-15%, +10%)
  • Heatsink Fan Rating: 20VA @ 110/120V AC or 220/240V AC
  • DV/DT Protection: RC snubber network for power circuit
  • Repetitive Peak Inverse Voltage: 1400V per UL/CSA/NEMA
  • Operating Frequency: 50/60 Hz for power circuit
  • Line Connected Motor Power (Max): 90 kW @ 690V/Y AC, 50 Hz, 3-phase
  • Delta Connected Motor Power (Max): 90 kW @ 400/415V AC, 50 Hz, 3-phase
  • Rated Impulse Voltage: 6000V per IEC
  • Dielectric Withstand: 2500V per IEC
  • Line Connected Motor Current: 27–108 A @ 600/Y/690V AC, 3-phase
  • Delta Connected Motor Current: 47–187 A @ 500/575V AC, 3-phase
  • Transient Protection: Metal oxide varistors: 220 J (optional)
  • Insulation Voltage: Rated 500V per IEC
  • Rated Operational Voltage: 200–480V AC (-15%, +10%) per UL/CSA/NEMA
  • Input OFF-State Current: <10 mA AC, <3 mA DC for control circuit
  • Short-Circuit Protection Device List: Standard fuse, circuit breaker, and high capacity time delay class CC/J/L
  • Number of Contacts: 1 for auxiliary contacts
  • High Capacity Available Fault Current (Max): 70kA @ 600V, maximum current 300 A time delay Class J or Class L fuse for inside delta connected motors
  • Type of Current: AC for auxiliary contacts
  • Conventional Thermal Current (Ith): AC/DC: 5 A for auxiliary contacts
  • Type of Control Circuit: Electromagnetic relay for auxiliary contacts
  • Type of Contacts: Programmable NO/NC for auxiliary contacts
  • Utilization Category: MG 1 per UL/CSA/NEMA for power circuit
  • Standard Controller Feature: Status indication: stopped, starting, stopping, at speed, alarm, and fault
  • Standard Available Fault Current (Max): 70kA @ 690V for maximum FLC
  • Optional Controller Feature: SMB smart motor braking control – provides motor braking without additional equipment; braking current adjustable from 0–400% of motor full-load current rating
  • Rated Control Supply Voltage at DC: 24 V
  • Integrated Motor Overload Protection: True
  • Short Circuit Protection Device Performance (SCPD) Type: Type 1
  • Number of Sensors (Max): 6 for PTC input ratings
  • Inrush Current Control Module: 5A @ 24V DC (-15%, +10%)
  • Voltage at PTC Terminals (RPTC = open), Max: 30V
  • Transient Watts Control Module: 60 W @ 24V DC (-15%, +10%)
  • Steady State Watts Control Module: 24 W @ 24V DC (-15%, +10%)
  • Voltage at PTC Terminals (RPTC = 4 kΩ), Max: <7.5 V
  • Response Time: 800 ms for PTC input ratings
  • Inrush Time Control Module: 250 ms @ 24V DC (-15%, +10%)
  • Transient Time Control Module: 500 ms @ 24V DC (-15%, +10%)
  • Cold Resistance of PTC Sensor Chain (Max): 1500 Ω
  • Tachometer Input: 0–5V DC @ 4.5V DC = 100% Speed
  • Allen Bradley Power Supply Control Module (Min): 1606-XLP50E @ 24V DC (-15%, +10%)
  • Short Circuit Trip Resistance: 25 Ω ± 10 Ω
  • Response Resistance: 3400 Ω ± 150 Ω
  • Reset Resistance: 1600 Ω ± 100 Ω
  • Input OFF-State Voltage (Max): 50V AC @ 10V DC/12V AC for control circuit
  • Input ON-State Voltage (Min): 85V AC @ 19.2V DC/20.4V AC for control circuit
  • Rated Operational Current: 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
  • Input ON-State Current: 20mA @ 120V AC / 40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit
  • Contact Type: Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3), and 33/34 (Aux #4)
  • Steady State Heat Dissipation with Control and Fan Power: 91 W
  • Storage and Transportation Temperature: -20 °C
  • Humidity: 5–95% (noncondensing)
  • Operating Temperature: Open: -5 to 50 °C (23 to 122 °F)
  • Protection Against Electrical Shock: IP2X (with terminal covers) per IEC for power circuit
  • EMC Emission Levels: Radiated emission: Class A
  • EMC Immunity Levels: Surge transient: per EN/IEC 60947-4-2
  • Altitude: 2000 m
  • Pollution Degree: 2
  • Weight: 15 kg
  • Shock: Opsal: 5.5 G
  • Width: 196.4 mm (7.74 in)
  • Depth: 212.2 mm (8.35 in)
  • Height: 443.7 mm (17.47 in)
  • Power Pole Construction: Heatsink hockey puck thyristor modular design
  • Vibration: Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
  • Make: 3600VA for auxiliary contacts
  • Break: 360VA for auxiliary contacts
  • Internal Bypass: True
  • Function: Single direction
  • Power Terminal Markings: NEMA, CENELEC EN50 012
  • Control Terminals: Clamping yoke connection, M3 screw clamp
  • Line/Load Side Power Terminals: One M10 x 1.5 diam hole per power pole
  • Number of Poles: 3
  • Enclosure: Open type
  • Control Modules Construction: Thermoset and thermoplastic moldings
  • Metal Parts Construction: Plated brass, copper, or painted steel

Key Performance Characteristics

  • Overload current for line connected devices: 27 A
  • Overload current for delta connected devices: 47 A
  • Trip classes: 10, 15, 20, and 30
  • Trip current rating: 117% of motor FLC
  • Integrated motor overload protection: True
  • Internal bypass: True

FAQ

  • Q: What is the current rating of the 150-F108NBRB?
    A: The controller handles 108 A for line connected motors and 47 A for delta connected motors.
  • Q: Which trip classes does this soft starter support?
    A: It supports trip classes 10, 15, 20, and 30.
  • Q: What is the operating temperature range?
    A: The open-type controller operates from -5 to 50 °C (23 to 122 °F).
  • Q: Does this model include integrated motor overload protection?
    A: Yes, the 150-F108NBRB includes integrated motor overload protection.
  • Q: What is the rated control supply voltage?
    A: It accepts 24 V AC at 50/60 Hz and 24 V DC.
  • Q: How many auxiliary contacts does it provide?
    A: It provides one auxiliary contact with programmable NO/NC configuration.
  • Q: What shipping methods do you use?
    A: We ship via FedEx, UPS, and DHL.
  • Q: What is the return policy?
    A: We support returns within 30 days.

Contact Information

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most