150-F625NBEB Allen-Bradley Smart Motor Controller
No reviews
In stock (14 units), ready to be shipped
-
Vendor:
Allen-Bradley
-
Type:
Smart Motor Controller
-
Country of Origin:
USA
-
Dimensions:
56*22*23cm
- Weight:
30000 g
- Tags: Smart motor controller
150-F625NBEB SMC Flex Open Smart Motor Controller – 625 A Soft Starter by Allen-Bradley
Key Technical Specifications
- Brand: Allen-Bradley
- Model: 150-F625NBEB
- Series: SMC Flex
- Category: Soft Starter / Smart Motor Controller
- Controller Type: Bulletin 150, Solid State Controller
- Controller Rating: 625 A, 500 Hp at 460V AC
- Input Line Voltage: 200–480V AC, 3-Phase, 50/60 Hz
- Control Voltage: 100–120V AC
- Rated Operating Voltage Ue: 200 V
- Rated Control Supply Voltage: 110 V at 50 Hz and 60 Hz AC
- Overload Current: 208 A for line connected devices, 283 A for delta connected devices
- Trip Classes: 10, 15, 20 and 30
- Trip Current Rating: 117% of motor FLC
- Line Connected Motor Power, Max: 800 Hp at 600V AC, 60 Hz, 3-phase
- Delta Connected Motor Power, Max: 900 Hp at 575V AC, 60 Hz, 3-phase
- Line Connected Motor Current: 208–625 A at 600/Y/690V AC, 3-phase
- Delta Connected Motor Current: 283–850 A at 500/575V AC, 3-phase
- Operating Frequency: 50/60 Hz for power circuit
- Insulation Voltage: Rated 500V per IEC for power circuit
- Rated Operational Voltage: 200–480V AC (-15%, +10%) per UL/CSA/NEMA
- Rated Impulse Voltage: 6000V per IEC for power circuit
- Dielectric Withstand: 2500V per IEC for power circuit
- DV/DT Protection: RC snubber network for power circuit
- Repetitive Peak Inverse Voltage: 1400V per UL/CSA/NEMA for power circuit
- Transient Protection: Metal oxide varistors 220 J (optional) for power circuit
- Short-Circuit Protection Device List: Standard fuse, circuit breaker and high capacity time delay class CC/J/L
- High Capacity Available Fault Current, Max: 74 kA at 600V with 1600 A time delay Class J or Class L fuse for line connected motors
- Standard Available Fault Current, Max: 70 kA at 690V for maximum FLC
- Integrated Motor Overload Protection: True
- Short Circuit Protection Device Performance (SCPD) Type: Type 1
- Number of Sensors, Max: 6 for PTC input ratings
- PTC Input Ratings: Voltage at terminals max 30V (RPTC = open), max <7.5V (RPTC = 4 kΩ), response time 800 ms, cold resistance max 1500 Ω, short circuit trip resistance 25 Ω ± 10 Ω, response resistance 3400 Ω ± 150 Ω, reset resistance 1600 Ω ± 100 Ω
- Tachometer Input: 0–5V DC at 4.5V DC = 100% Speed
- Transformer Rating Control Module: 751 VA (recommended 800 VA)
- Heatsink Fan Rating: 150VA at 110/120V AC or 220/240V AC
- Auxiliary Contacts: 1 contact, AC type, conventional thermal current 5 A, rated operational current 3A at 120V AC and 1.5A at 240V AC, make 3600VA, break 360VA
- Contact Type: Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
- Control Circuit: Electromagnetic relay for auxiliary contacts, programmable NO/NC
- Input OFF-State Current: <10 mA AC, <3 mA DC for control circuit
- Input OFF-State Voltage, Max: 50V AC at 10V DC/12V AC for control circuit
- Input ON-State Voltage, Min: 85V AC at 19.2V DC/20.4V AC for control circuit
- Input ON-State Current: 20mA at 120V AC, 40mA at 240V AC, 7.6mA at 24V AC/DC for control circuit
- Steady State Heat Dissipation with Control and Fan Power: 446 W
- Operating Temperature: Open: -5 to 50 °C (23 to 122 °F)
- Storage and Transportation Temperature: -20 °C
- Humidity: 5–95% (noncondensing)
- Altitude: 2000 m
- Pollution Degree: 2
- Protection Against Electrical Shock: IP00 (open device) per IEC for power circuit
- EMC Emission Levels: Radiated emission Class A
- EMC Immunity Levels: Surge transient per EN/IEC 60947-4-2
- Shock: Opsal 4 G
- Vibration: Opsal 1.0 G peak, 0.15 mm (0.006 in) displacement
- Weight: 179 kg
- Dimensions: Width 596.9 mm (23.50 in), Depth 346.2 mm (13.63 in), Height 1041.1 mm (41 in)
FAQ
-
Q: What is the current rating of the 150-F625NBEB?
A: The controller rating is 625 A and it supports 500 Hp at 460V AC. -
Q: What input voltage does this controller accept?
A: It accepts 200–480V AC, 3-phase, 50/60 Hz. -
Q: What control voltage does the 150-F625NBEB require?
A: It uses 100–120V AC for the control circuit. -
Q: Does this model include pump control?
A: Yes, the 150-F625NBEB includes pump control as a standard option. -
Q: Does this soft starter include integrated motor overload protection?
A: Yes, it includes integrated motor overload protection. -
Q: What is the operating temperature range?
A: The open type unit operates from -5 to 50 °C (23 to 122 °F). -
Q: Is the 150-F625NBEB in stock?
A: Yes, we have it in stock and ship within 5 days. -
Q: What shipping methods do you use?
A: We ship via FedEx, UPS, and DHL. -
Q: What is your return policy?
A: We support 30-day returns. -
Q: Is this product new and original?
A: Yes, it is brand new and original.
Contact Information Inquiries: sales@nex-auto.com +86 153 9242 9628
Partner NexAuto Technology Limited : https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.