IS200TBTCH1B Thermocouple Terminal Board – GE Mark VI Speedtronic
Technical Specifications
- Brand: General Electric
- Model: IS200TBTCH1B
- Product Type: Thermocouple Input Terminal Board
- Number of Channels: 24 channels
- Thermocouple Types: E, J, K, S, T
- Additional Types: B, N, R with PTCCH2 in Mark VIe systems
- Span: -8 mV to +45 mV
- Operating Temperature: 0 to +45°C
- Size: 15.9 cm high x 17.8 cm
- Availability: In Stock
- Country of Origin: United States
- Noise Suppression: High-frequency noise suppression
- Reference: Two cold junction reference devices
- Signal Processing: Analog-to-digital conversion and linearization by I/O processor
- Input Distance: Up to 300 meters (984 feet) from turbine control panel
- Maximum Two-Way Cable Resistance: 450 Ω
Functional Description
- The IS200TBTCH1B serves Mark VI and Mark VIe turbine control systems.
- It natively accepts 24 type E, J, K, S, or T thermocouple inputs.
- It supports additional B, N, and R types only with PTCCH2 in Mark VIe systems.
- Thermocouple inputs connect to two barrier-type terminal blocks.
- The board communicates with the I/O processor through DC-type connectors.
- TBTCH1C suits simplex applications and uses two DC-type connectors.
- TBTCH1B suits TMR applications and uses six DC-type connectors.
- In Mark VI systems, TBTC works with the VTCC processor.
- A single TBTCH1C connects to one VTCC using two cables.
- A TBTCH1B connects to three VTCC boards using six cables.
- Mark VI systems handle 24 inputs, while Mark VIe systems handle 12 inputs.
Installation Guide
- Connect thermocouple wires directly to the two I/O terminal blocks.
- These removable blocks mount on the terminal board and secure with two screws.
- Each block contains 24 terminals that accept up to #12 AWG wires.
- A shield terminal strip connects to chassis ground on the left side of each block.
- For Mark VI systems, cable the TBTC J-type connectors to I/O processors in the VME rack.
- Keep thermocouple inputs within 300 meters of the turbine control panel.
- Maintain two-way cable resistance below 450 Ω for reliable operation.
Operation Notes
- The 24 thermocouple inputs can be grounded or ungrounded.
- The board provides high-frequency noise suppression for stable readings.
- Two cold junction reference devices support accurate temperature measurement.
- The I/O processor manages analog-to-digital conversion and linearization.
- Mark VI simplex systems use TBTCH1C with one VTCC processor.
- Mark VIe simplex systems use two PTCC packs plugged into the TBTC.
- TMR systems use TBTCH1B, where thermocouple signals fan out to three J-connectors.
- The TBTC board supports all thermocouple spans documented for its I/O processor.
Package List
- 1 x IS200TBTCH1B Thermocouple Terminal Board
- 2 x Removable I/O terminal blocks
- 2 x Mounting screws for each terminal block
- 1 x Shield terminal strip attached to chassis ground
- Shipping methods: FedEx, UPS, DHL
FAQ
-
Q: What is the condition of the IS200TBTCH1B?
A: We provide brand new original products. -
Q: Do you have the IS200TBTCH1B in stock?
A: Yes, we keep it in stock for immediate order processing. -
Q: How fast do you ship the IS200TBTCH1B?
A: We ship within 5 days after order confirmation. -
Q: Which logistics carriers do you use?
A: We use common carriers such as DHL, FedEx, and UPS. -
Q: Can I return the IS200TBTCH1B?
A: Yes, we support returns within 30 days. -
Q: How many thermocouple channels does the IS200TBTCH1B support?
A: It supports 24 thermocouple input channels. -
Q: Which thermocouple types can the IS200TBTCH1B accept?
A: It accepts E, J, K, S, and T types natively. -
Q: What is the input span of the IS200TBTCH1B?
A: The span is -8 mV to +45 mV. -
Q: What is the operating temperature range?
A: The operating temperature range is 0 to +45°C. -
Q: How far can thermocouples be from the control panel?
A: They can be up to 300 meters away. -
Q: What is the maximum two-way cable resistance?
A: The maximum allowable two-way cable resistance is 450 Ω. -
Q: Does the IS200TBTCH1B support TMR applications?
A: Yes, it supports TMR applications with six DC-type connectors. -
Q: Which processor works with the TBTC in Mark VI systems?
A: The VTCC processor works with the TBTC in Mark VI systems.
Contact Information
- Inquiries: sales@nex-auto.com
- Phone / WhatsApp: +86 153 9242 9628
Partner NexAuto Technology Limited: https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.