Skip to product information
1 of 3

Honeywell TC-OAV061 6-Point Isolated Voltage Module

In stock (16 units), ready to be shipped
  • Vendor:

    Honeywell

  • Type:

    Analog Output Module

  • Country of Origin:

    USA

  • Dimensions:

    14*14*5cm

  • Weight:

    500 g

  • Tags: Analog output module

Honeywell TC-OAV061 Analog Output Module — 6-Point Isolated Voltage Output

Key Technical Specifications

  • Brand: Honeywell
  • Model: TC-OAV061
  • Category: Analog Output Module
  • Number of Points: 6 galvanically isolated channels
  • Output Voltage Range: ±10.50 VDC into loads of 1 KΩ or larger
  • Voltage Resolution: 14 bits across 21 V (1.4 millivolts), 13 bits across 10.5 V plus sign bit
  • Output Impedance: Less than 3 Ω
  • Open Circuit Detection: None
  • Output Overvoltage Protection: 24 VAC/VDC continuous at room temperature
  • Open Short Circuit Protection: Continuous with electronic current limiting
  • Calibrated Accuracy @ 25℃: Better than 0.1% of range
  • RFI Immunity: Error of less than 2.0% of range at 10 V/m, 27 to 1000 MHz
  • Module Update Rate for All Channels: 25 ms
  • Output Settling Time: Less than 2 ms to 95% of final value with resistive loads
  • Output Offset Drift with Temperature: 60 µV/℃ typical
  • Output Gain Drift with Temperature: 50 ppm/℃ typical
  • Power Dissipation: 4.9 W max
  • Backplane Current: See Module Power Consumption Data
  • Isolation Voltage — Channel to Channel: 100% tested at 2546 VDC for 1s
  • Isolation Voltage — User to System: 100% tested at 2546 VDC for 1s
  • Connection Terminal Blocks: TC-TBNH, 20-position terminal block

Performance and Environmental Durability

  • The module maintains better than 0.1% calibrated accuracy at 25℃ for reliable process control.
  • Each channel offers galvanic isolation tested at 2546 VDC for one second between channel and system.
  • The TC-OAV061 tolerates continuous 24 VAC/VDC overvoltage at room temperature without damage.
  • Electronic current limiting provides continuous short-circuit protection for each output point.
  • RFI immunity keeps error below 2.0% of range even at 10 V/m from 27 to 1000 MHz.
  • Typical offset drift stays at 60 µV/℃, while gain drift remains at 50 ppm/℃ for stable output.

Installation Guide

  • Mount the module in a Honeywell I/O rack that supports the TC-OAV061 analog output series.
  • Use the TC-TBNH 20-position terminal block for field wiring and secure each connection firmly.
  • Keep output loads at 1 KΩ or larger to meet the ±10.50 VDC output voltage range.
  • Route signal cables away from high-voltage lines to preserve RFI immunity and accuracy.
  • Verify backplane current limits before powering the rack, because the module dissipates up to 4.9 W.
  • Allow less than 2 ms settling time for resistive loads when configuring your control loop.

Package List

  • 1 × Honeywell TC-OAV061 Analog Output Module
  • 1 × TC-TBNH 20-position terminal block
  • 1 × Anti-static protective bag
  • 1 × Protective foam packaging

Shipping and Support

  • We ship with FedEx, UPS, and DHL to most international destinations.
  • Our team dispatches in-stock items within 5 days after order confirmation.
  • You may request a return within 30 days under our standard return policy.
  • All units are brand new and original from the manufacturer.

FAQ

  • Q: What is the output voltage range of the TC-OAV061?
    A: It provides ±10.50 VDC into loads of 1 KΩ or larger.
  • Q: How many isolated channels does this module offer?
    A: It has 6 galvanically isolated channels for independent analog output.
  • Q: What resolution does the TC-OAV061 deliver?
    A: It offers 14 bits across 21 V, equal to 1.4 millivolts per step.
  • Q: How fast does the module update all channels?
    A: The module updates all channels in 25 ms.
  • Q: What is the settling time for resistive loads?
    A: It settles to 95% of final value in less than 2 ms.
  • Q: Which terminal block fits this module?
    A: The TC-TBNH 20-position terminal block connects directly to the module.
  • Q: How does the module handle short circuits?
    A: It provides continuous short-circuit protection with electronic current limiting.
  • Q: What is the calibrated accuracy at 25℃?
    A: Accuracy is better than 0.1% of range at 25℃.

Contact Information Inquiries: sales@nex-auto.com or +86 153 9242 9628.

Partner NexAuto Technology Limited: https://www.nex-auto.com/

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most