Honeywell TC-IXL061 Thermocouple Input Module — 6-Point Analog Input
Key Technical Specifications
- Brand: Honeywell
- Model: TC-IXL061
- Category: Thermocouple Input Module
- Replacement Notice: Replaced by TC/TK-IXL062; terminal block rewiring required
- Number of Points: 6 channels plus 1 cold junction channel
- Nominal Input Voltage Ranges: -12 mV to +78 mV; -12 mV to +30 mV (high resolution)
- Supported Thermocouple Types: B, E, J, K, R, S, T, N, C
- Resolution: 16 bits (1.4 µV typical); 0.70 µV on high resolution range
- Accuracy (-12 mV to +78 mV Range): 0.1% FSR ±90 µV at 25℃
- Accuracy (-12 mV to +30 mV Range): 0.1% FSR ±42 µV at 25℃
- Accuracy (Cold Junction Sensor): Local CJ sensor error from ±0.3 to ±3.0℃ depending on channel; remote CJ sensor error ±0.3℃
- Common Mode Rejection: 120 dB @ 60 Hz, 100 dB @ 50 Hz
- Module Update Rate for All Channels: 50 milliseconds
- Settling Time to 5% of Full Scale: Less than 80 milliseconds
- Open Circuit Detection: Open TC detection time 5 seconds typical; upscale reading
- Channel Bandwidth: 0 to 15 Hz (-3 db)
- Normal Mode Noise Rejection: 60 dB @ 60 Hz
- RFI Immunity: Error of less than 2.0% of range at 10 V/m, 27 to 1000 MHz
- Overvoltage Capability: 120 VAC/VDC continuous at 25℃
- Input Offset Drift with Temperature: 0.5 µV/℃ typical
- Gain Drift with Temperature: 65 ppm/℃ typical
- Power Dissipation: 4.3 W max
- Backplane Current: See Module Power Consumption Data, page 46
- Spare CJR Thermistor Model Number: TC-CJRT01 (part no. 51109433-100)
- Isolation Voltage — Channel to Channel: 100% tested at 2546 VDC for 1s
- Isolation Voltage — User to System: 100% tested at 2546 VDC for 1s
- Connection Terminal Blocks: TC-TBNH, 20-position terminal block
Performance and Environmental Durability
- The module achieves 0.1% FSR accuracy at 25℃ across both input voltage ranges.
- Each channel provides galvanic isolation tested at 2546 VDC for one second between channel and system.
- The TC-IXL061 survives continuous 120 VAC/VDC overvoltage at 25℃ without damage.
- Common mode rejection reaches 120 dB at 60 Hz for stable readings in noisy plants.
- RFI immunity keeps error below 2.0% of range even at 10 V/m from 27 to 1000 MHz.
- Typical input offset drift stays at 0.5 µV/℃, while gain drift remains at 65 ppm/℃.
Installation Guide
- Mount the module in a Honeywell I/O rack that supports the TC-IXL061 thermocouple input series.
- Use the TC-TBNH 20-position terminal block for field wiring and secure each connection firmly.
- Rewire the terminal block when replacing this module with the TC/TK-IXL062 version.
- Use a new pre-wire cable when your system relies on an RTP (Remote Termination Panel).
- Place the chassis inside a NEMA 4 or NEMA 12 enclosure to hold ±3℃ reference junction compensation.
- Size the enclosure at roughly 24 in. wide, 20 in. high, and 8 in. deep (610 mm × 508 mm × 203 mm).
- Route thermocouple wiring away from high-voltage lines to preserve noise rejection and accuracy.
Package List
- 1 × Honeywell TC-IXL061 Thermocouple Input Module
- 1 × TC-TBNH 20-position terminal block
- 1 × Anti-static protective bag
- 1 × Protective foam packaging
Shipping and Support
- We ship with FedEx, UPS, and DHL to most international destinations.
- Our team dispatches in-stock items within 5 days after order confirmation.
- You may request a return within 30 days under our standard return policy.
- All units are brand new and original from the manufacturer.
FAQ
-
Q: What is the replacement model for the TC-IXL061?
A: Honeywell replaced it with the TC/TK-IXL062, which needs terminal block rewiring. -
Q: Which thermocouple types does this module support?
A: It supports B, E, J, K, R, S, T, N, and C thermocouple types. -
Q: What input voltage ranges does the TC-IXL061 offer?
A: It provides -12 mV to +78 mV and a high resolution -12 mV to +30 mV range. -
Q: What resolution does the module deliver?
A: It offers 16 bits (1.4 µV typical) and 0.70 µV on the high resolution range. -
Q: How fast does the module update all channels?
A: The module updates all channels in 50 milliseconds. -
Q: What is the open thermocouple detection time?
A: It detects an open thermocouple in 5 seconds typical with an upscale reading. -
Q: Which terminal block fits this module?
A: The TC-TBNH 20-position terminal block connects directly to the module. -
Q: What is the overvoltage capability?
A: It handles 120 VAC/VDC continuous at 25℃. -
Q: What spare cold junction thermistor should I order?
A: Order the TC-CJRT01 thermistor, part number 51109433-100.
Contact Information Inquiries: sales@nex-auto.com or +86 153 9242 9628.
Partner NexAuto Technology Limited: https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.