Home
6ES7431-7KF00-0AB0 Siemens S7-400 - Analog Input Module
1
/
of
3
6ES7431-7KF00-0AB0 Siemens S7-400 - Analog Input Module
No reviews
In stock (14 units), ready to be shipped
-
Vendor:
Siemens
-
Type:
Analog Input Module
-
Country of Origin:
DE
-
Dimensions:
29*21*2.5cm
- Weight:
500 g
- Tags: Analog input module
6ES7431-7KF00-0AB0 — Siemens SIMATIC S7-400 Analog Input Module SM 431
Key Technical Specifications
- Brand: Siemens — a trusted name in industrial automation.
- Model: 6ES7431-7KF00-0AB0 — part of the SIMATIC S7-400 family.
- Category: Analog input module SM 431, isolated, 8 AI channels.
- Resolution: 16-bit with overrange, including sign bit.
- Conversion time: 20 ms per channel for precise measurement.
- Input current: Max. 1200 mA from backplane bus at 5 V DC.
- Power loss: Typically 4.6 W during normal operation.
- Isolation: Tested with 1500 V DC for safe industrial use.
Voltage and Current Input Ranges
- Voltage ranges: ±20 mV, ±50 mV, ±80 mV, ±100 mV, ±250 mV, ±500 mV.
- Additional voltage ranges: ±1 V, ±2.5 V, ±5 V, ±10 V, and 1–5 V.
- Input resistance: Over 2000 ohms for 1–5 V range; 50 ohms for 4–20 mA.
- Current ranges: 0–20 mA, ±3.2 mA, ±5 mA, ±10 mA, ±20 mA, and 4–20 mA.
- Permissible input voltage: Max. 35 V continuous; 75 V for up to 1 s.
- Permissible input current: Max. 32 mA for current inputs.
Thermocouple Support and Temperature Compensation
- Thermocouple types: B, E, J, K, L, N, R, S, T, and U.
- Input resistance: Over 2000 ohms for Type B and Type N thermocouples.
- Internal compensation: Yes — built-in cold junction compensation.
- External compensation: Yes — with compensation socket 6ES7431-7KF00-6AA0.
- Dynamic reference temperature: Yes — supports changing reference values.
- Linearization: Parameterizable for all supported thermocouple types.
Accuracy, Diagnostics, and Alarms
- Operational error: ±0.3 % for voltage; ±0.5 % for current over full temperature range.
- Basic error at 25 °C: ±0.1 % for voltage; ±0.17 % for current.
- Diagnostics function: Yes — fully parameterizable for system monitoring.
- Diagnostic alarm: Yes — triggers when faults occur.
- Limit value alarm: Yes — alerts when signals exceed set thresholds.
- Hardware interrupt: Yes — parameterizable for fast event response.
- Interference suppression: Selectable for 400 Hz, 60 Hz, 50 Hz, or 10 Hz.
Isolation, Installation, and Physical Data
- Channel isolation: Yes — each channel is isolated from the others.
- Backplane isolation: Yes — channels are isolated from the backplane bus.
- Shielded cable length: Max. 200 m for reliable signal transmission.
- Dimensions: 25 mm wide, 290 mm high, and 210 mm deep.
- Weight: Approximately 650 g — easy to handle during installation.
- Integration time: Parameterizable with 2.5 ms, 16.7 ms, 20 ms, or 100 ms options.
- Basic conversion time: 10 ms, 16.7 ms, 20 ms, or 100 ms per channel.
Installation Guide
- Mount the module in a Siemens S7-400 rack with proper backplane connection.
- Use shielded twisted-pair cables for all analog signal connections.
- Connect thermocouple compensation socket 6ES7431-7KF00-6AA0 for external cold junction.
- Keep cable length under 200 m to maintain measurement accuracy.
- Configure input ranges, diagnostics, and alarms in STEP 7 software.
- Verify wiring polarity before power-up to protect the module.
- Allow warm-up to 25 °C for best accuracy and lowest error.
- Do not exceed 35 V continuous input voltage to avoid damage.
Package Contents
- 1 × Siemens 6ES7431-7KF00-0AB0 analog input module SM 431.
- 1 × Quick reference guide for wiring and configuration.
- 1 × Protective shipping carton with anti-static foam.
Shipping and Support
- We ship via FedEx, UPS, and DHL — select your courier at checkout.
- Our stock is ready for immediate dispatch within 5 days after payment.
- We accept returns within 30 days for unused items in original packaging.
- Contact us for bulk orders or technical questions about this Siemens module.
FAQ
-
Q: What is the resolution of the 6ES7431-7KF00-0AB0?
A: It provides 16-bit resolution with overrange, including the sign bit. -
Q: Which thermocouple types does this module support?
A: It supports Type B, E, J, K, L, N, R, S, T, and U thermocouples. -
Q: Does this module have channel isolation?
A: Yes, each channel is isolated from the others and from the backplane bus. -
Q: What is the conversion time for this module?
A: The basic conversion time is 20 ms per channel, with parameterizable options. -
Q: Can I use this module for resistance measurement?
A: No, it does not support resistance or resistance thermometer measurement. -
Q: What is the maximum shielded cable length?
A: You can use shielded cables up to 200 meters long without signal degradation. -
Q: Does this module support external cold junction compensation?
A: Yes, it works with compensation socket 6ES7431-7KF00-6AA0 for external compensation. -
Q: What is the power loss of this module?
A: The typical power loss is 4.6 W during normal operation. -
Q: What diagnostics functions does this module offer?
A: It provides parameterizable diagnostics, diagnostic alarms, limit value alarms, and hardware interrupts. -
Q: How do I suppress interference at 50 Hz or 60 Hz?
A: You can parameterize the interference suppression frequency in STEP 7 software.
Contact Information
- Inquiries: sales@nex-auto.com
- Phone/WhatsApp: +86 153 9242 9628
- Partner: NexAuto Technology Limited
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.














