Skip to product information
1 of 3

330102-00-40-10-02-00 3300 XL Probe Bently Nevada

In stock (15 units), ready to be shipped
  • Vendor:

    Bently Nevada

  • Type:

    8mm Probe

  • Country of Origin:

    USA

  • Dimensions:

    25*25*5cm

  • Weight:

    323 g

  • Tags: 8mm probe

3300 XL 8 mm Proximity Probes by Bently Nevada

Key Technical Specifications

  • Linear Range: 2 mm (80 mils), starting at 0.25 mm (10 mils) from the target.
  • Recommended Gap (Radial Vibration): -9 Vdc, approximately 1.27 mm (50 mils).
  • DC Resistance (RPROBE): 7.59 ± 0.50 Ω for the 1.0 meter probe length.
  • Field Wiring: 0.2 to 1.5 mm² (16-24 AWG), 3-conductor shielded triad, max 305 m (1000 ft).
  • Probe Tip Material: Polyphenylene sulfide (PPS) for rugged durability.
  • Probe Case Material: AISI 303 or 304 stainless steel (SST).

Environmental & Mechanical Ratings

  • Standard Temp Range: -52°C to +177°C (-62°F to +350°F).
  • Extended Temp Range (Tip): -52°C to +218°C (-62°F to +425°F).
  • Relative Humidity: Less than 3% ASF change after 56 days at 93% RH (IEC 68-2-3).
  • Thread Engagement: 3/8-24 UNF, maximum length 0.563 inches.
  • Weight: 323 g/m (11.4 oz per meter).
  • Pressure Seal: Viton® O-ring seals differential pressure (factory testing available on request).

Hazardous Area Approvals

  • Intrinsically Safe (ia): Class I, Zone 0 AEx/Ex ia IIC T5…T1 Ga; Class I, Groups A,B,C,D; Class II/III.
  • Non-incendive (nA/ec): Class I, Zone 2 AEx/Ex nA IIC T5…T1 Gc; Class I, Div 2, Groups A,B,C,D.
  • Temperature Schedule (Probe only): T1 (-55°C to +232°C) through T5 (-55°C to +40°C) for EPL Ga/Gc.
  • Complies with EPL Dc temperature classifications from T280°C to T90°C.

Frequently Asked Questions (FAQ)

  • Q: What is the exact linear range for the 3300 XL probe?
    A: It provides a 2 mm (80 mil) linear range from 0.25 mm to 2.3 mm (10 to 90 mils) from the target.
  • Q: Can I use this probe with extended field wiring lengths?
    A: Yes, up to 305 meters (1000 feet) using 3-conductor shielded triad cable; check frequency response for signal rolloff.
  • Q: What is the recommended gap setting for radial vibration?
    A: Set the gap to -9 Vdc, which corresponds to approximately 1.27 mm (50 mils).
  • Q: Is the probe suitable for high-temperature applications?
    A: Yes, the extended temperature range probe tip withstands -52°C to +218°C (-62°F to +425°F).
  • Q: Do you have this model in stock?
    A: Yes, we keep the 330102-00-40-10-02-00 in stock for immediate delivery.
  • Q: What are the agency approvals for hazardous areas?
    A: It carries AEx/Ex ia IIC T5…T1 Ga (Zone 0) and AEx/Ex nA IIC T5…T1 Gc (Zone 2) certifications.

Contact Information Inquiries: sales@nex-auto.com , +86 153 9242 9628 (WhatsApp).

Partner NexAuto Technology Limited: https://www.nex-auto.com/

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most