ABB 07-KT-96 Advant Controller Basic Unit Overview
Core Technical Specifications
- Brand & Model: ABB, 07-KT-96 (Order Number GJR5 2529 00 R).
- Digital I/O Capacity: 24 digital inputs and 16 digital transistor outputs.
- Analog I/O: No onboard analog inputs or outputs (expandable via CS31 bus).
- System Bus Expansion: CS31 bus supports up to 31 remote modules for I/O scaling.
- Integrated Memory: 480 kB Flash EPROM and 480 kB RAM for user program and configuration.
- High-Speed Counters: 1 to 2 counters with 7 operating modes, max 50 kHz frequency.
- Real-Time Clock: Integrated RTC with exchangeable battery backup.
- Processing Speed: Typical 0.3 ms per 1 kB program (65% bits, 35% words), or 0.22 ms optimized.
Digital I/O Details and Electrical Characteristics
- Digital Inputs (24 channels): 3 groups of 8, signal 0 (-30V...+5V) / signal 1 (+13V...+30V).
- Digital Outputs (16 transistor): 2 groups of 8, 500 mA rated (max 625 mA), short-circuit protected.
- Terminals 20 to 27: Assigned to E 63,00 through E 63,07 for digital I/O connections.
- Power Supply: Rated 24 V DC, max current 0.35 A, with reverse polarity protection.
- LED Indicators: Green and yellow LEDs display signal statuses for each channel.
- Wiring: Withdrawable screw-type terminal blocks for easy installation and maintenance.
- Electrical Isolation: Groups are isolated from each other and from other circuitry.
- Cable Length: Unshielded max 600 m (inputs) and 400 m (outputs), shielded up to 1000 m.
Communication and Expansion Features
- Serial Interfaces: 2 ports for programming or connection to HMI devices.
- CS31 System Bus: Expands I/O up to 1032 digital I/O and 224 analog channels in total.
- Memory Expansion: SmartMedia Card (Flash) for data storage and program reload.
- Data Memory: 8192 bit flags, 8192 word flags, 1024 double-word flags, and 256 sequencers.
- Variables: 256 kB variables including 16 kB RETAIN for data retention.
- Execution Control: Cyclic and time-controlled multitasking (up to 20 tasks).
- Special Functions: MODBUS® protocols, PI/PID controllers, 32-bit arithmetic, and floating-point math.
- Programming Software: 907 AC 1131 for flexible program development and online modifications.
Hardware Protection and Mounting
- Password Protection: User program secured by password to prevent unauthorized access.
- Data Backup: Exchangeable lithium battery for RAM retention and RTC backup.
- Real-Time Clock: Integrated RTC with 1-second resolution for time-stamped operations.
- Mounting Options: Supports DIN rail snapping or direct screw mounting.
- Output Protection: Short-circuit, overload, and reverse polarity protection on outputs.
- Inductive Loads: Internal varistor demagnetization for reliable switching.
- Diagnosis Functions: Self-diagnosis and CS31 system bus diagnosis for easier troubleshooting.
- RUN/STOP Switch: Manual switch for starting and aborting program execution.
Installation, Packaging, and Logistics
- Installation Guide: Use withdrawable screw terminals; ensure proper grounding and wiring per manual.
- Package Contents: Basic unit 07-KT-96, terminal blocks, documentation, and battery.
- Shipping Options: We dispatch via FedEx, UPS, or DHL within 5 business days.
- Stock Status: All items are brand new and in stock for immediate shipment.
- Return Policy: 30-day return window for unused items in original packaging.
- Mounting Accessories: DIN rail clips and screws are included in the package.
- Wiring Notes: Use appropriate cable gauges; CS31 bus wiring meets 2.5 mm² specification.
- System Integration: Works as stand-alone, bus master, or slave in Advant Controller 31 systems.
Frequently Asked Questions (FAQ)
-
Q: Does the 07-KT-96 have analog I/O onboard?
A: No, this unit provides 24 digital inputs and 16 digital outputs only. Analog I/O is available via CS31 expansion. -
Q: Can I configure this unit as a bus master?
A: Yes, the 07-KT-96 operates as stand-alone, bus master, or slave in the Advant Controller system. -
Q: What is the maximum I/O expansion capability?
A: Via CS31 bus, you can expand to 1032 digital I/O and 224 analog channels in total. -
Q: How do I back up the program and data?
A: Use the SmartMedia Card (Flash) or the integrated battery-backed RAM for data retention. -
Q: What is the processing time for 1 kB of program?
A: Typical cycle time is 0.3 ms (65% bits, 35% words), or 0.22 ms in optimized mode. -
Q: Are the terminal blocks removable?
A: Yes, they are withdrawable screw-type terminal blocks for easy wiring and maintenance. -
Q: What is the counting frequency of the fast counters?
A: The counters operate up to 50 kHz with 7 configurable operating modes. -
Q: Does the unit include a real-time clock?
A: Yes, it has an integrated RTC with 1-second resolution and battery backup.
For inquiries, contact us: sales@nex-auto.com or +86 153 9242 9628 (WhatsApp).
Partner: NexAuto Technology Limited
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.