Skip to product information
1 of 3

V18347-2041150001 ABB TZIDC-120 Positioner

In stock (13 units), ready to be shipped

ABB V18347-2041150001 TZIDC-120 Electro-Pneumatic Positioner for FOUNDATION Fieldbus

Technical Specifications

  • Brand: ABB
  • Model: V18347-2041150001
  • Series: TZIDC-120
  • Type: Electro-pneumatic positioner, intelligent, configurable
  • Communication: FOUNDATION Fieldbus input
  • Explosion protection: ATEX EEx ia IIC T6
  • Output / safe position: Single acting, fail safe on electrical power failure
  • Case: Varnished aluminium, mechanical position indicator, IP 65 / NEMA 4X
  • Mounting: Linear actuator per DIN/IEC 534/NAMUR, or rotary actuator per VDI/VDE 3845
  • Connections: Cable thread M20 x 1.5, air pipe thread 1/4-18 NPT
  • Option module for shutdown: Without
  • Mechanical kit for digital position feedback: Without
  • Design: Standard varnish and coding

Environmental Capabilities and Operating Limits

  • Ambient temperature: -40 °C to +85 °C for operation, storage and transport
  • Ambient temperature with proximity switches SJ2-S1N (NO): -25 °C to +85 °C
  • Relative humidity, operational: 95 % annual average with closed housing and air supply on, condensation permissible
  • Relative humidity, transport and storage: 75 % annual average, non-condensing
  • Case material and protection: Aluminium with IP 65 / NEMA 4X
  • Surface and colour: Electrostatic dipping varnish with epoxy resin, stove-hardened, black RAL 9005 matt case, Pantone 420 cap
  • Weight: 1.7 kg

Electrical and Pneumatic Connections

  • Screw terminals: max. 1.0 mm² for options, max. 2.5 mm² for analog signal
  • Notice: Do not expose the terminals to strain
  • Cable entry: 2 threads 1/2-14 NPT or M20 x 1.5, 1 with cable gland and 1 with pipe plug
  • Pneumatic connections: Threads G 1/4 or 1/4-18 NPT
  • Important: The fail-safe action helps protect the valve position when electrical power fails.

Installation Guide

  • Mount the V18347-2041150001 to a linear actuator per DIN/IEC 534/NAMUR or to a rotary actuator per VDI/VDE 3845.
  • Use the mechanical position indicator to confirm the actuator stroke or angle during setup.
  • Connect the air pipe with 1/4-18 NPT thread and keep the supply air clean and dry.
  • Wire the FOUNDATION Fieldbus cable through the M20 x 1.5 entry and tighten the cable gland.
  • Keep screw terminals free from strain and respect the maximum wire sizes shown above.
  • Check the IP 65 / NEMA 4X seal after mounting in outdoor or washdown areas.
  • Verify the safe position after electrical power failure before placing the loop into service.

Measurement and Performance Notes

  • The TZIDC-120 series provides intelligent, configurable valve position control.
  • The positioner reads the valve position and compares it with the Fieldbus setpoint.
  • The unit then adjusts the pneumatic output to reduce position error.
  • Linear and rotary motion both benefit from the mechanical position indicator.
  • The robust aluminium case resists vibration, dust and moisture in process plants.
  • The ATEX EEx ia IIC T6 rating supports use in hazardous gas atmospheres.

Package List

  • 1 x ABB V18347-2041150001 TZIDC-120 positioner
  • 1 x cable gland
  • 1 x pipe plug
  • 1 x mechanical position indicator, pre-installed
  • 1 x mounting accessory set for NAMUR or VDI/VDE 3845 mounting
  • 1 x quick start guide

Shipping and Support

  • We ship with FedEx, UPS and DHL to most international destinations.
  • We keep this item in stock and dispatch it within 5 days.
  • We offer 30-day returns for eligible orders.
  • All units are brand new and original.

FAQ

  • Q: What communication protocol does the V18347-2041150001 use?
    A: It uses FOUNDATION Fieldbus for digital communication with the control system.
  • Q: What is the ambient temperature range?
    A: The standard range is -40 °C to +85 °C, and -25 °C to +85 °C with certain proximity switches.
  • Q: What is the explosion protection rating?
    A: The unit carries ATEX EEx ia IIC T6 certification for hazardous areas.
  • Q: What is the safe position on power failure?
    A: It is single acting and fail safe, so the valve moves to its safe position when electrical power fails.
  • Q: What are the pneumatic connection threads?
    A: The air pipe connection uses 1/4-18 NPT thread, with G 1/4 also listed for the series.
  • Q: How much does the positioner weigh?
    A: The unit weighs approximately 1.7 kg.
  • Q: Do you have this item in stock?
    A: Yes, we keep it in stock and ship within 5 days.

Contact Information Inquiries: sales@nex-auto.com , +86 153 9242 9628

Partner NexAuto Technology Limited : https://www.nex-auto.com/

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most