ABB V18347-2041150001 TZIDC-120 Electro-Pneumatic Positioner for FOUNDATION Fieldbus
Technical Specifications
- Brand: ABB
- Model: V18347-2041150001
- Series: TZIDC-120
- Type: Electro-pneumatic positioner, intelligent, configurable
- Communication: FOUNDATION Fieldbus input
- Explosion protection: ATEX EEx ia IIC T6
- Output / safe position: Single acting, fail safe on electrical power failure
- Case: Varnished aluminium, mechanical position indicator, IP 65 / NEMA 4X
- Mounting: Linear actuator per DIN/IEC 534/NAMUR, or rotary actuator per VDI/VDE 3845
- Connections: Cable thread M20 x 1.5, air pipe thread 1/4-18 NPT
- Option module for shutdown: Without
- Mechanical kit for digital position feedback: Without
- Design: Standard varnish and coding
Environmental Capabilities and Operating Limits
- Ambient temperature: -40 °C to +85 °C for operation, storage and transport
- Ambient temperature with proximity switches SJ2-S1N (NO): -25 °C to +85 °C
- Relative humidity, operational: 95 % annual average with closed housing and air supply on, condensation permissible
- Relative humidity, transport and storage: 75 % annual average, non-condensing
- Case material and protection: Aluminium with IP 65 / NEMA 4X
- Surface and colour: Electrostatic dipping varnish with epoxy resin, stove-hardened, black RAL 9005 matt case, Pantone 420 cap
- Weight: 1.7 kg
Electrical and Pneumatic Connections
- Screw terminals: max. 1.0 mm² for options, max. 2.5 mm² for analog signal
- Notice: Do not expose the terminals to strain
- Cable entry: 2 threads 1/2-14 NPT or M20 x 1.5, 1 with cable gland and 1 with pipe plug
- Pneumatic connections: Threads G 1/4 or 1/4-18 NPT
- Important: The fail-safe action helps protect the valve position when electrical power fails.
Installation Guide
- Mount the V18347-2041150001 to a linear actuator per DIN/IEC 534/NAMUR or to a rotary actuator per VDI/VDE 3845.
- Use the mechanical position indicator to confirm the actuator stroke or angle during setup.
- Connect the air pipe with 1/4-18 NPT thread and keep the supply air clean and dry.
- Wire the FOUNDATION Fieldbus cable through the M20 x 1.5 entry and tighten the cable gland.
- Keep screw terminals free from strain and respect the maximum wire sizes shown above.
- Check the IP 65 / NEMA 4X seal after mounting in outdoor or washdown areas.
- Verify the safe position after electrical power failure before placing the loop into service.
Measurement and Performance Notes
- The TZIDC-120 series provides intelligent, configurable valve position control.
- The positioner reads the valve position and compares it with the Fieldbus setpoint.
- The unit then adjusts the pneumatic output to reduce position error.
- Linear and rotary motion both benefit from the mechanical position indicator.
- The robust aluminium case resists vibration, dust and moisture in process plants.
- The ATEX EEx ia IIC T6 rating supports use in hazardous gas atmospheres.
Package List
- 1 x ABB V18347-2041150001 TZIDC-120 positioner
- 1 x cable gland
- 1 x pipe plug
- 1 x mechanical position indicator, pre-installed
- 1 x mounting accessory set for NAMUR or VDI/VDE 3845 mounting
- 1 x quick start guide
Shipping and Support
- We ship with FedEx, UPS and DHL to most international destinations.
- We keep this item in stock and dispatch it within 5 days.
- We offer 30-day returns for eligible orders.
- All units are brand new and original.
FAQ
-
Q: What communication protocol does the V18347-2041150001 use?
A: It uses FOUNDATION Fieldbus for digital communication with the control system. -
Q: What is the ambient temperature range?
A: The standard range is -40 °C to +85 °C, and -25 °C to +85 °C with certain proximity switches. -
Q: What is the explosion protection rating?
A: The unit carries ATEX EEx ia IIC T6 certification for hazardous areas. -
Q: What is the safe position on power failure?
A: It is single acting and fail safe, so the valve moves to its safe position when electrical power fails. -
Q: What are the pneumatic connection threads?
A: The air pipe connection uses 1/4-18 NPT thread, with G 1/4 also listed for the series. -
Q: How much does the positioner weigh?
A: The unit weighs approximately 1.7 kg. -
Q: Do you have this item in stock?
A: Yes, we keep it in stock and ship within 5 days.
Contact Information Inquiries: sales@nex-auto.com , +86 153 9242 9628
Partner NexAuto Technology Limited : https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.