TSXDSY16R5 Schneider Electric 16 Relay Output Module – Modicon Premium

Technical Specifications

  • Brand: Schneider Electric
  • Model: TSXDSY16R5
  • Series: Modicon Premium Automation platform
  • Category: Discrete output module – 16 relay outputs
  • Discrete output number: 16
  • Discrete output type: Relay, not protected
  • Discrete output voltage: 12...24 V DC (EN/IEC 61131-2, 10...34 V); 24...240 V AC (EN/IEC 61131-2, 20...264 V)
  • [Ith] conventional free air thermal current: 3 A
  • Response time: < 10 ms deactivation; < 8 ms activation
  • Contacts type and composition: 1 NO
  • Output overvoltage protection: AC inductive by RC circuit MOV (ZNO) on each preactuator; DC inductive by discharge diode on each preactuator
  • Output overload protection: 1 external fast-blow fuse per channel or group of channels
  • Short-circuit protection: 1 external fast-blow fuse per channel or group of channels
  • Insulation resistance: > 10 MOhm at 500 V
  • Power dissipation: 0.25 W + 0.2 W × number of outputs at state 1
  • Electrical connection: Screw terminal block
  • Current consumption: 135 mA at 24 V DC rack; 80 mA at 5 V DC
  • Module format: Standard
  • Product weight: 0.38 kg

Electrical Durability

  • DC-12 24 W 24 V resistive: 1,000,000 cycles; DC-3 24 W 24 V inductive: 1,000,000 cycles.
  • DC-3 10 W 24 V inductive: 2,000,000 cycles; DC-12 40 W 24 V resistive: 300,000 cycles.
  • AC-12 220 VA 220 V resistive: 1,000,000 cycles; AC-14 and AC-15 220 VA 220 V inductive: 100,000 cycles.
  • AC-12 110 VA 110 V resistive: 1,000,000 cycles; AC-14 and AC-15 110 VA 220 V inductive: 1,000,000 cycles.
  • AC-12 50 VA 48 V resistive: 1,000,000 cycles; AC-14 and AC-15 24 VA 48 V inductive: 2,000,000 cycles.
  • AC-14 and AC-15 50 VA 220 V inductive: 3,000,000 cycles; AC-14 and AC-15 10 VA inductive: 5,000,000 cycles.

Environmental and Compliance Data

  • Dielectric strength: 2000 V at 50/60 Hz for 60 s.
  • Standards: 73/23/EEC, 89/336/EEC, 92/31/EEC, 93/68/EEC, CSA C22.2 No 142, IEC 61131-2, UL 508, CSA C22.2 No 213 Class I Division 2 Groups A/B/C/D.
  • Product certifications: ABS, BV, DNV, GL, LR, RINA, RMRS; marking CE.
  • Ambient air temperature for operation: 0...60 °C; storage: -25...70 °C.
  • Relative humidity: 10...95 % without condensation for operation; 5...95 % for storage.
  • Operating altitude: 0...2000 m; protective treatment TC; IP degree of protection IP20; pollution degree 2.

Installation Guide

  • Fit the module into the Modicon Premium rack and tighten the screw terminal block connections.
  • Wire the field loads to the 1 NO contacts and respect the rated DC and AC voltage windows.
  • Install one external fast-blow fuse per channel or channel group for overload and short-circuit protection.
  • Add an RC circuit MOV on AC inductive loads and a discharge diode on DC inductive loads.
  • Keep ambient air temperature between 0 and 60 °C and avoid condensation on the module.
  • Respect pollution degree 2 and the IP20 rating inside the enclosure.

Package Contents

  • 1 x TSXDSY16R5 discrete output module
  • 1 x Screw terminal block set
  • 1 x Product documentation
  • Package weight: 0.38 kg

Shipping

  • We ship orders through FedEx, UPS, and DHL.
  • Stock items leave our warehouse within 5 days.
  • You receive tracking details once the carrier collects your parcel.

FAQ

  • Q: What output type does the TSXDSY16R5 offer?
    A: It offers 16 relay outputs with 1 NO contact composition and screw terminal connections.
  • Q: Which voltages does this module switch?
    A: It switches 12...24 V DC and 24...240 V AC field voltages.
  • Q: What is the thermal current rating?
    A: The conventional free air thermal current reaches 3 A.
  • Q: How fast do the relay outputs respond?
    A: Activation takes less than 8 ms and deactivation takes less than 10 ms.
  • Q: How do I protect the outputs?
    A: Use one external fast-blow fuse per channel or group, plus MOV on AC inductive loads and a diode on DC inductive loads.
  • Q: What is the operating temperature range?
    A: The module operates from 0 to 60 °C and stores from -25 to 70 °C.
  • Q: Do you keep this module in stock and how fast do you ship?
    A: We keep brand new original stock and ship within 5 days via DHL, FedEx, or UPS. We support 30-day returns.

Contact Information

Inquiries: sales@nex-auto.com , +86 153 9242 9628

Partner NexAuto Technology Limited : https://www.nex-auto.com/

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most