Home
AAR181-S50 Yokogawa RTD Input Module 12-Channel
1
/
of
3
AAR181-S50 Yokogawa RTD Input Module 12-Channel
No reviews
In stock (14 units), ready to be shipped
-
Vendor:
Yokogawa
-
Type:
Digital Input Module
-
Country of Origin:
ID
-
Dimensions:
12*13*3cm
- Weight:
300 g
- Tags: Digital input module
Yokogawa AAR181-S50 – 12-Channel Isolated RTD Input Module
Technical Specifications
- Manufacturer: Yokogawa Electric Corporation
- Model: AAR181-S50
- Product Type: RTD Input Module (Isolated)
- Number of Input Channels: 12 isolated channels (CH1 to CH12)
- Input Signal Type: RTD Pt100 (3-wire type)
- Applicable Standards: JIS C1604:1997 and IEC751:1995
- Allowable Input Voltage: ±5 V (maximum input range)
- Withstanding Voltage: 1500 V AC for 1 minute between input and system
- Input Resistance (Power ON): 2 MΩ or larger
- Input Resistance (Power OFF): 2 MΩ or larger
- Accuracy (RTD): ±120 mΩ
- Allowable Total Wiring Resistance: 40 Ω or less per wire
- Measurement Current (RTD): 1 mA (constant current excitation)
- Temperature Drift: ±120 mΩ / 10 °C for RTD input
- Data Update Period: 1 second (fixed cycle)
- Burn-out Detection: Configurable per module (UP/DOWN selection)
- Burn-out Detection Time: 60 seconds
- Maximum Current Consumption: 450 mA at 5 V DC
- Weight: Approximately 0.2 kg (lightweight design)
- External Connection: Pressure clamp terminal (direct wiring)
Key Functional Features
- Suffix Code -S: Standard type for general RTD measurement applications.
- Suffix Code 5: No explosion protection – suitable for non-hazardous areas.
- Suffix Code 0: Basic type with standard feature set.
- 3-Wire RTD Support: Eliminates lead wire resistance errors for accurate readings.
- Channel Isolation: Each of the 12 channels is independently isolated from the system.
- Burn-out Detection: Detects sensor or wiring failures and drives output UP or DOWN.
- Dual-Redundant Ready: Supports system redundancy for critical temperature loops.
Frequently Asked Questions (FAQ)
-
Q: What RTD types does the AAR181-S50 support?
A: The AAR181-S50 supports Pt100 (100 Ω at 0 °C) in a 3-wire configuration per JIS and IEC standards. -
Q: How does the burn-out detection work on this module?
A: You can set burn-out per module to UP or DOWN. The module detects an open circuit or broken sensor within 60 seconds. -
Q: What is the total resistance limit for RTD wiring?
A: The allowable total resistance per wire (including sensor and lead wires) is 40 Ω or less for guaranteed accuracy. -
Q: Can I use this module with 2-wire RTD sensors?
A: The AAR181-S50 is optimized for 3-wire connections. For 2-wire sensors, you must short the INA and INC terminals externally. -
Q: What is the data update rate for temperature readings?
A: The module updates all 12 channel data every 1 second in normal operation. -
Q: Does this module support redundant system configurations?
A: Yes, the AAR181-S50 works with Yokogawa's dual-redundant architecture for critical process loops. -
Q: How do I compensate for accuracy when measuring below 0 °C?
A: Multiply the specified RTD accuracy (±120 mΩ) by coefficient K based on the thermoelectromotive force ratio at the measured temperature.
Contact Information Inquiries: sales@nex-auto.com , +86 153 9242 9628
Partner NexAuto Technology Limited : https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.