Skip to product information
1 of 3

Vibration Transmitter Bently Nevada 990-08-50-01-00

In stock (20 units), ready to be shipped
  • Vendor:

    Bently Nevada

  • Type:

    Vibration Transmitter

  • Country of Origin:

    USA

  • Dimensions:

    10*7.4*5.3cm

  • Weight:

    820 g

  • Tags: Vibration transmitter

Bently Nevada 990-08-50-01-00 Vibration Transmitter Product

Key Technical Specifications

  • Brand & Model: Bently Nevada 990-08-50-01-00
  • Full-Scale Range: 0 to 8 mils peak-to-peak (0 to 200 μm pp)
  • Frequency Response: 5 Hz to 6,000 Hz (+0, -3 dB)
  • System Cable Length: 5.0 meters (16.4 feet) standard configuration
  • Loop Accuracy: Within ±1.5% of full-scale range
  • Power Supply: Requires +12 to +35 Vdc input
  • Signal Output: 4 to 20 mA dc two-wire configuration
  • Current Limiting: 23 mA typical for circuit protection
  • Maximum Loop Resistance: 1,000 Ω at 35 Vdc
  • Mounting Type: 35 mm DIN rail clips for easy installation

Installation & Operation Details

  • Sensor Compatibility: Accepts one 3300 NSv Proximity Probe
  • Probe Gap Setting: Install between 0.5-1.75 mm (20-55 mils) from target
  • Minimum Target Size: 9.5 mm (0.375 inches) diameter minimum
  • Calibration Adjustments: Non-interacting external zero and span controls
  • Fault Response: Output drops below 3.6 mA within 100 µs during NOT OK condition
  • Recovery Time: Normal output restores within 2-3 seconds after fault clearance
  • Cable Distance: Maximum 3 meters (10 feet) from probe to BNC connector
  • Environmental Rating: Suitable for Non-Hazardous and Zone 2/Div 2 areas

Frequently Asked Questions (FAQ)

  • What vibration range does this model measure?
    The 990-08-50-01-00 covers 0-8 mils peak-to-peak (0-200 micrometers).
  • How do I mount this transmitter in my panel?
    It includes 35 mm DIN rail clips for quick and secure industrial panel mounting.
  • What happens during a sensor fault condition?
    The output immediately drops below 3.6 mA to clearly indicate a NOT OK status.
  • Can I use longer extension cables than specified?
    We recommend staying within the 5-meter system length for optimal performance.
  • Is this unit suitable for hazardous locations?
    Yes, it carries approvals for Zone 2 and Division 2 hazardous area installation.
  • What power supply voltage works best?
    A 28 Vdc supply is recommended, but any voltage between +12 to +35 Vdc will work.

For complete details, download the full 990 datasheet here.

Contact Information for Technical Inquiries:
Email: sales@nex-auto.com
Phone/WhatsApp: +86 153 9242 9628

Authorized Partner: NexAuto Technology Limited

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most