Home
TC-PIA081 Honeywell Analog Input Module
1
/
of
3
TC-PIA081 Honeywell Analog Input Module
No reviews
In stock (15 units), ready to be shipped
-
Vendor:
Honeywell
-
Type:
Analog Current Input Module
-
Country of Origin:
USA
-
Dimensions:
7*8*4cm
- Weight:
220 g
- Tags: Analog current input module
TC-PIA081 Honeywell Analog Current Input Module – 8-Points
- Brand & Model: Honeywell TC-PIA081 – an 8-point analog current input module (discontinued, replaced by TC-PIA082).
- Input Capacity: Supports 8 single-ended input channels referenced to a single common.
- Input Types: Accepts 2-wire and 3-wire transmitters with a 4-20mA signal range (extendable 2-22mA).
- Input Voltage: Delivers >15V @ 22mA to power the field transmitters.
- Accuracy & Drift: Provides 0.1% signal accuracy with a temperature drift of 50 ppm/°C.
- Resolution & Response: Offers 16-bit resolution and a 4 ms response time to 99% of final value.
Intrinsically Safe Field Circuit Values
- 2-Wire Input: Uo = 23.7V, Io = 92.5mA, Po = 548mW. Lo ≤ 10mH (IIB) or 2.5mH (IIC); Co ≤ 560nF (IIB) or 66nF (IIC).
- 3-Wire Input: Uo = 23.7V, Io = 93.5mA, Po = 555mW. Lo ≤ 10mH (IIB) or 2.5mH (IIC); Co ≤ 560nF (IIB) or 66nF (IIC).
- Galvanic Isolation: Isolates input from backplane bus and power supply per DIN EN 50 020. (No isolation between input channels.)
Filtering & Alarm Features
- Filter Cutoff: Configurable for channel groups 0-3 and 4-7 at 0.5, 1, 2, 4, or 10 Hz.
- Common Mode Rejection: Achieves 120dB rejection at 50-60Hz for noise immunity.
- Fault Detection: Detects lead breakage (I < 2mA) and short circuit (V < 4V). Flashes red LED for faults.
- Configurable Alarms: Supports overrange, underrange, transmitter fault, and lead breakage alarms per channel.
Environmental & Physical Specifications
- Temperature Range: Operates from –20°C to 70°C (–4°F to 158°F). Stores from –20°C to 100°C (–4°F to 212°F).
- Humidity & Gas Resistance: Withstands 95% RH (non-condensing) and passes ISA-S71.04-1985 Pollution Gas Test Level G3.
- Shock & Vibration: Endures 15g peak shock (11ms) and 2g vibration (10-500Hz) per IEC 68-2-6.
- Protection Class: Rated IP20 – requires an external IP54 (or better) housing for field installation.
- Weight & Dimensions: Light at 0.203 kg (0.45 lb). Measures 76 x 94 x 46 mm (3.0 x 3.7 x 1.8 inches).
- Power: Consumes 0.95 power supply unit load with 5.2W dissipation. Powered through terminal base.
- Keyswitch Position: Set to position 3 for proper backplane configuration.
Installation & Wiring Guide
- Mounting: Install the TC-PIA081 into the designated slot on the terminal base.
- 2-Wire Wiring: Connect to terminal pairs: Ch0 (0,1), Ch1 (4,5), Ch2 (8,9), Ch3 (12,13), Ch4 (17,18), Ch5 (21,22), Ch6 (25,26), Ch7 (29,30).
- 3-Wire Wiring: Connect to terminal triples: Ch0 (0,1,2), Ch1 (4,5,6), Ch2 (8,9,10), Ch3 (12,13,14), Ch4 (17,18,19), Ch5 (21,22,23), Ch6 (25,26,27), Ch7 (29,30,31).
- Cable Requirement: Use shielded multicore cable with individual channel shields for EMC compliance (isolation >500V).
Package Contents
- One Honeywell TC-PIA081 analog input module (8 points).
- Terminal base connector kit (sold separately – check compatibility).
- Quick-start installation guide (certificates and 12-month warranty not included).
Shipping & Logistics
- Stock & Delivery: We keep the TC-PIA081 in stock while supplies last. We ship within 5 business days after order confirmation.
- Carrier Options: Select FedEx, UPS, or DHL for fast, trackable worldwide delivery.
- Returns: We accept returns within 30 days for unused items in original packaging.
Frequently Asked Questions
- Is the TC-PIA081 a new original Honeywell part? Yes, we supply only brand-new, factory-sealed units from remaining stock.
- Why is this module discontinued? Honeywell replaced it with the TC-PIA082 – we offer this version for legacy system upgrades.
- Can I use this module in hazardous areas? Yes – it carries CENELEC II (1) 2G EEx ia/ib IIB/IIC T4 certification for intrinsically safe use.
- What transmitters does it support? It accepts both 2-wire and 3-wire transmitters with 4-20mA output.
- Does it provide channel-to-channel isolation? No – inputs share a common reference without isolation between channels.
- What cable should I use? Use shielded multicore cable with individual channel shields (isolation >500V) for CE compliance.
- Is the TC-PIA081 compatible with my existing ControlNet system? Yes – it uses the vendor-specific backplane bus and fits standard Honeywell terminal bases.
Contact Information Inquiries: sales@nex-auto.com , +86 153 9242 9628
Partner NexAuto Technology Limited : https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.