6ES7441-1AA03-0AE0 | Siemens SIMATIC S7-400 CP 441-1 Point-to-Point Communication Module
Technical Specifications
- Brand: Siemens
- Model: 6ES7441-1AA03-0AE0
- Series: SIMATIC S7-400
- Category: Point-to-Point Communication Module
- Manufacturer: Siemens
- Supply voltage: 5 V DC and 24 V DC
- Input current from backplane bus: 5 V DC, maximum 700 mA without interface module
- Interface modules: 20 mA TTY, RS 422/485 X.27, RS 232C V.24
- 20 mA TTY power consumption: Maximum 300 mA at 5 V and 45 mA at 24 V
- RS 422/485 power consumption: Maximum 300 mA at 5 V
- RS 232C power consumption: Maximum 300 mA at 5 V
- Memory requirements: 1 to 5 KB for parameters and 0 to 55 KB for message texts per interface
- Number of interfaces: 1 variable interface
- Supported interface physics: 20 mA TTY, RS 232C V.24, RS 422/485 X.27
- Shielded cable length: 1,000 m for 20 mA TTY, 10 m for RS 232, 1,200 m for RS 422/RS 485
- Maximum transmission rate: 38.4 kbit/s
- Supported printers: HP-Deskjet, HP-Laserjet, IBM-Proprinter, and user-defined models
- Integrated protocol drivers: 3964 R, ASCII, and Printer
- 20 mA TTY transmission rate: Maximum 19.2 kbit/s with 3964 R, ASCII, or printer driver
- RS 422/485 transmission rate: Maximum 38.4 kbit/s with 3964 R, ASCII, or printer driver
- RS 232 transmission rate: Maximum 38.4 kbit/s with 3964 R, ASCII, or printer driver
- Communication functions: S7 extended communication
- Total connections: 8
- Configuration software: STEP 7 with dedicated parameter assignment forms
- Dimensions: 25 mm width, 290 mm height, 210 mm depth
- Weight: Approximately 720 g, interface module approximately 100 g
Performance and Environmental Capabilities
- The module delivers stable point-to-point communication for industrial control systems.
- It supports long shielded cable runs for 20 mA TTY and RS 422/485 applications.
- The design helps resist electrical noise common in factory automation environments.
- Users can select the interface physics to match specific field devices and printers.
- The CP 441-1 handles serial protocols such as 3964 R and ASCII without extra hardware.
- Engineers can configure parameters through STEP 7 for fast commissioning and diagnostics.
Installation Guide
- Mount the module in a compatible SIMATIC S7-400 rack slot.
- Confirm the backplane bus provides 5 V DC and 24 V DC as required.
- Select the correct interface module for 20 mA TTY, RS 232C, or RS 422/485.
- Use shielded cables and respect the maximum cable length for each interface type.
- Connect the field device or printer according to the pin assignment for the chosen physics.
- Configure the module in STEP 7 with the correct protocol and transmission rate.
- Verify communication with a short test message before full production use.
Package List
- 1 x Siemens 6ES7441-1AA03-0AE0 CP 441-1 communication module
- 1 x Configuration package on CD
- 1 x Interface module, approximately 100 g, when included with the selected variant
Shipping and Support
- We keep this module in stock and ship it within 5 days after order confirmation.
- We ship by FedEx, UPS, and DHL for reliable international delivery.
- We accept returns within 30 days under our standard return policy.
- Contact us for bulk orders, spare parts, or technical selection support.
FAQ
-
Q: What is the condition of the 6ES7441-1AA03-0AE0?
A: We supply it as brand new original stock. -
Q: How many interfaces does this CP 441-1 module offer?
A: It provides one variable interface for point-to-point communication. -
Q: Which interface physics can I use?
A: You can use 20 mA TTY, RS 232C V.24, or RS 422/485 X.27. -
Q: What is the maximum transmission rate?
A: The module supports up to 38.4 kbit/s depending on the interface and protocol. -
Q: Which protocols does the module support?
A: It supports 3964 R, ASCII, and printer drivers. -
Q: What is the maximum cable length for RS 422/485?
A: Shielded RS 422/RS 485 cable can reach 1,200 m. -
Q: How many total connections can the module handle?
A: It supports up to 8 connections overall. -
Q: What configuration software do I need?
A: You need STEP 7 with the dedicated parameter assignment forms. -
Q: How much does the module weigh?
A: The module weighs approximately 720 g, and the interface module weighs about 100 g. -
Q: When do you ship, and which carriers do you use?
A: We ship in-stock items within 5 days by FedEx, UPS, or DHL.
Contact Information Inquiries: sales@nex-auto.com, +86 153 9242 9628
Partner NexAuto Technology Limited : https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.