S30B-3011CA SICK S300 Advanced Safety Laser Scanner

Technical Specifications

  • Brand: SICK
  • Model: S30B-3011CA
  • Series: S300 Series, S300 Advanced product version
  • Alternate Mfr Part Number: 1056428
  • Type: Safety laser scanner, sensor without system plug
  • Application: Indoor
  • Protective field range: 3 m
  • Warning field range: 8 m at 15 % reflectivity
  • Distance measuring range: 30 m
  • Scanning angle: 270°
  • Angular resolution: 0.5°
  • Resolution: 14 mm; configurable to 30 mm, 40 mm, 50 mm, 70 mm or 150 mm
  • Response time: 80 ms, depending on basic response time and multiple sampling
  • Protective field supplement: 100 mm
  • Multiple samplings: 2 to 16, configurable
  • Field sets: 4 field sets, 12 fields, triple field sets; 4 monitoring cases
  • Operating voltage: 24 V DC nominal, 16.8 to 30 V DC range
  • Power consumption: 0.33 A to 1.7 A
  • Outputs: 2 PNP semiconductors, short-circuit protected and cross-circuit monitored; OSSD pairs 2 × 250 mA; 3 application diagnostic outputs at 3 × 100 mA
  • Connection type: System plug with or without connecting cable; M12 5-pin male connector
  • Safety type: Type 3 per IEC 61496, SIL 2 per IEC 61508
  • Category and PL: Category 3 and PL d per EN ISO 13849
  • PFHD: 8.0 × 10⁻⁸ per hour
  • Mission time: 20 years per EN ISO 13849
  • Enclosure rating: IP65 per EN 60529
  • Housing material: Aluminum die cast, RAL 1021 yellow
  • Optics cover: Polycarbonate with scratch-resistant outer coating
  • Dimensions (W × H × D): 102 mm × 152 mm × 106 mm
  • Weight: 1.2 kg
  • Operating temperature: –10 °C to +50 °C
  • Storage temperature: –25 °C to +50 °C
  • Shock resistance: 16 g for 16 ms per IEC 60068-2-29; continuous shock 50 m/s² for 11 ms and 100 m/s² for 16 ms
  • Vibration resistance: Class 5M1 per IEC 60721-3-5 and related standards
  • Light source: Pulsed laser diode, 905 nm wavelength
  • Laser class: Class 1 per IEC 60825-1 and 21 CFR 1040.10/1040.11

Safety Performance Highlights

  • Certified protection: Type 3, SIL 2 and PL d ratings cover demanding machine guarding duties.
  • Fast reaction: The 80 ms response time keeps stopping distances short and predictable.
  • Fine detection: 14 mm resolution catches small intrusions in the protective field.
  • Flexible zoning: Four field sets and four monitoring cases adapt to changing work steps.
  • Fault-safe logic: At least one OSSD switches OFF when a fault occurs.
  • Reflector tolerance: The scanner detects remission factors from 1.8 % to over 1,000 %.

Configuration and Interfaces

  • You configure the scanner with a PC and the CDS Configuration and Diagnostic Software.
  • The RS-232 interface runs at 38.4 kBaud for setup and diagnostics.
  • The RS-422 data interface supports rates up to 500 kBaud.
  • Safe SICK device communication over EFI also reaches 500 kBaud.
  • Cable length can extend to 50 m with a 0.22 mm² conductor cross section.
  • The device offers 5 universal I/Os, including 1 EDM input and 1 reset/restart input.
  • The automatic reset delay is configurable from 2 s to 60 s.

Mounting Guide

  • Mount the scanner so the 270° scan plane covers the hazard zone without blind spots.
  • Keep the optics cover clean and free of scratches to protect detection accuracy.
  • Allow for the 100 mm protective field supplement when you calculate the safety distance.
  • Use the system plug and your chosen M12 5-pin cable to wire the OSSDs and inputs.
  • Feed 24 V DC within the 16.8 to 30 V DC range and respect Protection class III.
  • Verify the configured field sets and monitoring cases against your risk assessment.
  • Confirm the ambient stays between –10 °C and +50 °C and the enclosure keeps IP65.

Package Contents

  • 1 × SICK S30B-3011CA safety laser scanner
  • 1 × sensor unit without system plug
  • 1 × mounting hardware set
  • 1 × quick-start documentation

Shipping

  • We ship worldwide by FedEx, UPS and DHL.
  • We dispatch stock items within 5 days.
  • We pack each scanner in shock-absorbing material for safe transit.

FAQ

  • Q: Is the S30B-3011CA a new original unit?
    A: Yes, we supply a brand-new original S30B-3011CA scanner.
  • Q: Do you keep this scanner in stock?
    A: Yes, we hold stock and ship within 5 days.
  • Q: Which couriers do you use?
    A: We use common carriers such as DHL, plus FedEx and UPS.
  • Q: What is the return policy?
    A: You may return the product within 30 days.
  • Q: Does the sensor include a system plug?
    A: No, this model ships without a system plug, so you select the M12 5-pin cable.
  • Q: What are the protective and warning field ranges?
    A: The protective field reaches 3 m and the warning field reaches 8 m.
  • Q: What resolution and response time does it offer?
    A: It offers 14 mm resolution and an 80 ms response time.
  • Q: Which safety standards does the scanner meet?
    A: It meets Type 3, SIL 2, Category 3 and PL d requirements.
  • Q: What supply voltage does it need?
    A: It runs on 24 V DC, within a 16.8 to 30 V DC range.
  • Q: What is the enclosure rating and operating temperature?
    A: It offers IP65 and works from –10 °C to +50 °C.
  • Q: How many field sets and monitoring cases can I configure?
    A: You can configure 4 field sets across 12 fields and 4 monitoring cases.
  • Q: What are the dimensions and weight?
    A: The scanner measures 102 × 152 × 106 mm and weighs 1.2 kg.

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most