Home
Allen-Bradley 150-F60NBDB SMC Flex Soft Starter | 60A 460V
1
/
of
3
Allen-Bradley 150-F60NBDB SMC Flex Soft Starter | 60A 460V
No reviews
In stock (14 units), ready to be shipped
-
Vendor:
Allen-Bradley
-
Type:
Smart Motor Controller
-
Country of Origin:
USA
-
Dimensions:
32*15*20cm
- Weight:
5700 g
- Tags: Smart motor controller
Allen-Bradley 150-F60NBDB SMC Flex Smart Motor Controller
Technical Specifications
- Brand: Allen-Bradley
- Model: 150-F60NBDB
- Series: SMC Flex
- Controller type: Soft starter
- Controller rating: 60 A, 10–40 Hp @ 460 V AC
- Control voltage: 100…240 V AC
- Rated operating voltage (Ue): 200 V
- Rated control supply voltage: 100 V at 50/60 Hz
- Overload current (line connected): 12 A
- Overload current (delta connected): 20.8 A
- Trip classes: 10, 15, 20, and 30
- Trip current rating: 117% of motor FLC
- Transformer control module: 75 VA @ 100…240 V AC (-15%, +10%)
- Heatsink fan rating: 20 VA @ 110/120 V AC or 220/240 V AC
- DV/DT protection: RC snubber network for power circuit
- Repetitive peak inverse voltage: 1400 V per UL/CSA/NEMA
- Operating frequency: 50/60 Hz for power circuit
- Line connected motor power (max): 50 Hp @ 575 V AC, 60 Hz, 3-phase
- Delta connected motor power (max): 75 Hp @ 460 V AC, 60 Hz, 3-phase
- Rated impulse voltage: 6000 V per IEC
- Dielectric withstand: 2500 V per IEC
- Line connected motor current: 12…60 A @ 500/575 V AC, 3-phase
- Delta connected motor current: 20.8…104 A @ 500/575 V AC, 3-phase
- Transient protection: Metal oxide varistors: 220 J (optional)
- Insulation voltage: Rated 500 V per IEC
- Rated operational voltage: 200…480 V AC (-15%, +10%) per UL/CSA/NEMA
- Input OFF-state current: <10 mA AC, <3 mA DC for control circuit
- Short-circuit protection device list: Standard fuse, circuit breaker, and high capacity time delay class CC/J/L
- Number of contacts: 1 for auxiliary contacts
- High capacity available fault current (max): 70 kA @ 600 V, max current 200 A time delay Class J or Class L fuse for inside delta connected motors
- Type of current (auxiliary contacts): AC
- Conventional thermal current (Ith): AC/DC 5 A for auxiliary contacts
- Type of control circuit: Electromagnetic relay for auxiliary contacts
- Type of contacts: Programmable NO/NC for auxiliary contacts
- Utilization category: MG 1 per UL/CSA/NEMA for power circuit
- Standard controller feature: Status indication: stopped, starting, stopping, at speed, alarm, and fault
- Standard available fault current (max): 10 kA @ 200…600 V, maximum standard fuse 400 A for delta device operational current rating
- Optional controller feature: SMB smart motor braking control: provides motor braking without additional equipment, braking current adjustable from 0…400% of motor FLC
- Integrated motor overload protection: True
- Short circuit protection device performance (SCPD) type: Type 1
- Number of sensors (max): 6 for PTC input ratings
- Inrush current control module: 5 A @ 24 V DC (-15%, +10%)
- Voltage at PTC terminals (RPTC = open), max: 30 V for PTC input ratings
- Transient watts control module: 60 W @ 24 V DC (-15%, +10%)
- Steady state watts control module: 24 W @ 24 V DC (-15%, +10%)
- Voltage at PTC terminals (RPTC = 4 kΩ), max: <7.5 V for PTC input ratings
- Response time: 800 ms for PTC input ratings
- Inrush time control module: 250 ms @ 24 V DC (-15%, +10%)
- Transient time control module: 500 ms @ 24 V DC (-15%, +10%)
- Cold resistance of PTC sensor chain (max): 1500 Ω for PTC input ratings
- Tachometer input: 0…5 V DC @ 4.5 V DC = 100% Speed
- Allen-Bradley power supply control module (min): 1606-XLP50E @ 24 V DC (-15%, +10%)
- Short circuit trip resistance: 25 Ω ± 10 Ω for PTC input ratings
- Response resistance: 3400 Ω ± 150 Ω for PTC input ratings
- Reset resistance: 1600 Ω ± 100 Ω for PTC input ratings
- Input OFF-state voltage (max): 50 V AC @ 10 V DC / 12 V AC for control circuit
- Input ON-state voltage (min): 85 V AC @ 19.2 V DC / 20.4 V AC for control circuit
- Lower line side cable size: 0.8…2.5 mm² (18…14 AWG) for power terminals
- Lower load side cable size: 0.8…2.5 mm² (18…14 AWG) for power terminals
- Upper load side cable size: 2.5…50 mm² (14…1 AWG) for load power terminals
- Upper line side cable size: 2.5…95 mm² (14…3 AWG) for line power terminals
- Rated operational current (auxiliary contacts): 3 A @ 120 V AC, 1.5 A @ 240 V AC
- Input ON-state current: 20 mA @ 120 V AC / 40 mA @ 240 V AC, 7.6 mA @ 24 V AC/DC for control circuit
- Contact type: Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3), and 33/34 (Aux #4)
- Steady state heat dissipation with control and fan power: 97 W
- Storage and transportation temperature: -20 °C
- Humidity: 5…95% (noncondensing)
- Operating temperature: Open: -5 to 50 °C (23 to 122 °F)
- Protection against electrical shock: IP20 per IEC for power circuit
- EMC emission levels: Radiated emission: Class A
- EMC immunity levels: Surge transient: per EN/IEC 60947-4-2
- Altitude: 2000 m
- Pollution degree: 2
- Weight: 5.7 kg
- Shock: Operational: 15 G
- Width: 150 mm (5.90 in)
- Depth: 203 mm (8 in)
- Height: 321 mm (12.60 in)
- Power pole construction: Heatsink thyristor modular design
- Vibration: Operational: 1.0 G peak, 0.15 mm (0.006 in) displacement
- Make: 3600 VA for auxiliary contacts
- Break: 360 VA for auxiliary contacts
- Tightening torque: 14.7 Nm (130 in-lb) for power terminals
- Internal bypass: True
- Function: Single direction
- Power terminal markings: NEMA, CENELEC EN50 012
- Control terminals: Clamping yoke connection, M3 screw clamp
- Wire strip length: 18…20 mm (0.22…0.34 in) for power terminals
- Number of poles: 3
- Enclosure: Open type
- Control modules construction: Thermoset and thermoplastic moldings
- Metal parts construction: Plated brass, copper, or painted steel
Installation Guide
- Mount the controller vertically on a flat panel with adequate clearance.
- Use the specified cable sizes for line, load, and control terminals.
- Tighten power terminals to 14.7 Nm (130 in-lb) using a calibrated torque wrench.
- Connect control voltage between 100 and 240 V AC to the designated terminals.
- Ensure the heatsink fan receives 20 VA at 110/120 V AC or 220/240 V AC.
- Verify the short-circuit protection device matches Class CC, J, or L fuses.
- Program trip class and overload settings via the built-in display.
- Check the PTC sensor chain resistance stays below 1500 Ω for proper detection.
Package List
- 1 × Allen-Bradley 150-F60NBDB SMC Flex Smart Motor Controller
- 1 × Display module (integrated)
- 1 × Mounting hardware kit
- 1 × Terminal cover set
- 1 × User manual (English)
FAQ
- What is the control voltage range for this soft starter? The 150-F60NBDB accepts 100…240 V AC control voltage.
- Can I use this controller with a delta-connected motor? Yes, it supports delta-connected motors up to 75 Hp at 460 V AC.
- Does it include internal bypass? Yes, the internal bypass is true and reduces heat during run mode.
- What trip classes are available? You can select trip classes 10, 15, 20, and 30.
- What is the maximum operating altitude? The controller operates safely up to 2000 meters.
- Is the product new and original? Yes, we ship brand-new original units from stock.
- How fast do you ship? We dispatch within 5 days using FedEx, UPS, or DHL.
- What is your return policy? We accept returns within 30 days of delivery.
Contact Information Inquiries: sales@nex-auto.com | +86 153 9242 9628
Partner NexAuto Technology Limited: https://www.nex-auto.com/
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.