Skip to product information
1 of 3

Allen-Bradley 150-F60NBDB SMC Flex Soft Starter | 60A 460V

In stock (14 units), ready to be shipped
  • Vendor:

    Allen-Bradley

  • Type:

    Smart Motor Controller

  • Country of Origin:

    USA

  • Dimensions:

    32*15*20cm

  • Weight:

    5700 g

  • Tags: Smart motor controller

Allen-Bradley 150-F60NBDB SMC Flex Smart Motor Controller

Technical Specifications

  • Brand: Allen-Bradley
  • Model: 150-F60NBDB
  • Series: SMC Flex
  • Controller type: Soft starter
  • Controller rating: 60 A, 10–40 Hp @ 460 V AC
  • Control voltage: 100…240 V AC
  • Rated operating voltage (Ue): 200 V
  • Rated control supply voltage: 100 V at 50/60 Hz
  • Overload current (line connected): 12 A
  • Overload current (delta connected): 20.8 A
  • Trip classes: 10, 15, 20, and 30
  • Trip current rating: 117% of motor FLC
  • Transformer control module: 75 VA @ 100…240 V AC (-15%, +10%)
  • Heatsink fan rating: 20 VA @ 110/120 V AC or 220/240 V AC
  • DV/DT protection: RC snubber network for power circuit
  • Repetitive peak inverse voltage: 1400 V per UL/CSA/NEMA
  • Operating frequency: 50/60 Hz for power circuit
  • Line connected motor power (max): 50 Hp @ 575 V AC, 60 Hz, 3-phase
  • Delta connected motor power (max): 75 Hp @ 460 V AC, 60 Hz, 3-phase
  • Rated impulse voltage: 6000 V per IEC
  • Dielectric withstand: 2500 V per IEC
  • Line connected motor current: 12…60 A @ 500/575 V AC, 3-phase
  • Delta connected motor current: 20.8…104 A @ 500/575 V AC, 3-phase
  • Transient protection: Metal oxide varistors: 220 J (optional)
  • Insulation voltage: Rated 500 V per IEC
  • Rated operational voltage: 200…480 V AC (-15%, +10%) per UL/CSA/NEMA
  • Input OFF-state current: <10 mA AC, <3 mA DC for control circuit
  • Short-circuit protection device list: Standard fuse, circuit breaker, and high capacity time delay class CC/J/L
  • Number of contacts: 1 for auxiliary contacts
  • High capacity available fault current (max): 70 kA @ 600 V, max current 200 A time delay Class J or Class L fuse for inside delta connected motors
  • Type of current (auxiliary contacts): AC
  • Conventional thermal current (Ith): AC/DC 5 A for auxiliary contacts
  • Type of control circuit: Electromagnetic relay for auxiliary contacts
  • Type of contacts: Programmable NO/NC for auxiliary contacts
  • Utilization category: MG 1 per UL/CSA/NEMA for power circuit
  • Standard controller feature: Status indication: stopped, starting, stopping, at speed, alarm, and fault
  • Standard available fault current (max): 10 kA @ 200…600 V, maximum standard fuse 400 A for delta device operational current rating
  • Optional controller feature: SMB smart motor braking control: provides motor braking without additional equipment, braking current adjustable from 0…400% of motor FLC
  • Integrated motor overload protection: True
  • Short circuit protection device performance (SCPD) type: Type 1
  • Number of sensors (max): 6 for PTC input ratings
  • Inrush current control module: 5 A @ 24 V DC (-15%, +10%)
  • Voltage at PTC terminals (RPTC = open), max: 30 V for PTC input ratings
  • Transient watts control module: 60 W @ 24 V DC (-15%, +10%)
  • Steady state watts control module: 24 W @ 24 V DC (-15%, +10%)
  • Voltage at PTC terminals (RPTC = 4 kΩ), max: <7.5 V for PTC input ratings
  • Response time: 800 ms for PTC input ratings
  • Inrush time control module: 250 ms @ 24 V DC (-15%, +10%)
  • Transient time control module: 500 ms @ 24 V DC (-15%, +10%)
  • Cold resistance of PTC sensor chain (max): 1500 Ω for PTC input ratings
  • Tachometer input: 0…5 V DC @ 4.5 V DC = 100% Speed
  • Allen-Bradley power supply control module (min): 1606-XLP50E @ 24 V DC (-15%, +10%)
  • Short circuit trip resistance: 25 Ω ± 10 Ω for PTC input ratings
  • Response resistance: 3400 Ω ± 150 Ω for PTC input ratings
  • Reset resistance: 1600 Ω ± 100 Ω for PTC input ratings
  • Input OFF-state voltage (max): 50 V AC @ 10 V DC / 12 V AC for control circuit
  • Input ON-state voltage (min): 85 V AC @ 19.2 V DC / 20.4 V AC for control circuit
  • Lower line side cable size: 0.8…2.5 mm² (18…14 AWG) for power terminals
  • Lower load side cable size: 0.8…2.5 mm² (18…14 AWG) for power terminals
  • Upper load side cable size: 2.5…50 mm² (14…1 AWG) for load power terminals
  • Upper line side cable size: 2.5…95 mm² (14…3 AWG) for line power terminals
  • Rated operational current (auxiliary contacts): 3 A @ 120 V AC, 1.5 A @ 240 V AC
  • Input ON-state current: 20 mA @ 120 V AC / 40 mA @ 240 V AC, 7.6 mA @ 24 V AC/DC for control circuit
  • Contact type: Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3), and 33/34 (Aux #4)
  • Steady state heat dissipation with control and fan power: 97 W
  • Storage and transportation temperature: -20 °C
  • Humidity: 5…95% (noncondensing)
  • Operating temperature: Open: -5 to 50 °C (23 to 122 °F)
  • Protection against electrical shock: IP20 per IEC for power circuit
  • EMC emission levels: Radiated emission: Class A
  • EMC immunity levels: Surge transient: per EN/IEC 60947-4-2
  • Altitude: 2000 m
  • Pollution degree: 2
  • Weight: 5.7 kg
  • Shock: Operational: 15 G
  • Width: 150 mm (5.90 in)
  • Depth: 203 mm (8 in)
  • Height: 321 mm (12.60 in)
  • Power pole construction: Heatsink thyristor modular design
  • Vibration: Operational: 1.0 G peak, 0.15 mm (0.006 in) displacement
  • Make: 3600 VA for auxiliary contacts
  • Break: 360 VA for auxiliary contacts
  • Tightening torque: 14.7 Nm (130 in-lb) for power terminals
  • Internal bypass: True
  • Function: Single direction
  • Power terminal markings: NEMA, CENELEC EN50 012
  • Control terminals: Clamping yoke connection, M3 screw clamp
  • Wire strip length: 18…20 mm (0.22…0.34 in) for power terminals
  • Number of poles: 3
  • Enclosure: Open type
  • Control modules construction: Thermoset and thermoplastic moldings
  • Metal parts construction: Plated brass, copper, or painted steel

Installation Guide

  • Mount the controller vertically on a flat panel with adequate clearance.
  • Use the specified cable sizes for line, load, and control terminals.
  • Tighten power terminals to 14.7 Nm (130 in-lb) using a calibrated torque wrench.
  • Connect control voltage between 100 and 240 V AC to the designated terminals.
  • Ensure the heatsink fan receives 20 VA at 110/120 V AC or 220/240 V AC.
  • Verify the short-circuit protection device matches Class CC, J, or L fuses.
  • Program trip class and overload settings via the built-in display.
  • Check the PTC sensor chain resistance stays below 1500 Ω for proper detection.

Package List

  • 1 × Allen-Bradley 150-F60NBDB SMC Flex Smart Motor Controller
  • 1 × Display module (integrated)
  • 1 × Mounting hardware kit
  • 1 × Terminal cover set
  • 1 × User manual (English)

FAQ

  • What is the control voltage range for this soft starter? The 150-F60NBDB accepts 100…240 V AC control voltage.
  • Can I use this controller with a delta-connected motor? Yes, it supports delta-connected motors up to 75 Hp at 460 V AC.
  • Does it include internal bypass? Yes, the internal bypass is true and reduces heat during run mode.
  • What trip classes are available? You can select trip classes 10, 15, 20, and 30.
  • What is the maximum operating altitude? The controller operates safely up to 2000 meters.
  • Is the product new and original? Yes, we ship brand-new original units from stock.
  • How fast do you ship? We dispatch within 5 days using FedEx, UPS, or DHL.
  • What is your return policy? We accept returns within 30 days of delivery.

Contact Information Inquiries: sales@nex-auto.com | +86 153 9242 9628

Partner NexAuto Technology Limited: https://www.nex-auto.com/

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most