Yokogawa AAR181-S50 – 12-Channel Isolated RTD Input Module

Technical Specifications

  • Manufacturer: Yokogawa Electric Corporation
  • Model: AAR181-S50
  • Product Type: RTD Input Module (Isolated)
  • Number of Input Channels: 12 isolated channels (CH1 to CH12)
  • Input Signal Type: RTD Pt100 (3-wire type)
  • Applicable Standards: JIS C1604:1997 and IEC751:1995
  • Allowable Input Voltage: ±5 V (maximum input range)
  • Withstanding Voltage: 1500 V AC for 1 minute between input and system
  • Input Resistance (Power ON): 2 MΩ or larger
  • Input Resistance (Power OFF): 2 MΩ or larger
  • Accuracy (RTD): ±120 mΩ
  • Allowable Total Wiring Resistance: 40 Ω or less per wire
  • Measurement Current (RTD): 1 mA (constant current excitation)
  • Temperature Drift: ±120 mΩ / 10 °C for RTD input
  • Data Update Period: 1 second (fixed cycle)
  • Burn-out Detection: Configurable per module (UP/DOWN selection)
  • Burn-out Detection Time: 60 seconds
  • Maximum Current Consumption: 450 mA at 5 V DC
  • Weight: Approximately 0.2 kg (lightweight design)
  • External Connection: Pressure clamp terminal (direct wiring)

Key Functional Features

  • Suffix Code -S: Standard type for general RTD measurement applications.
  • Suffix Code 5: No explosion protection – suitable for non-hazardous areas.
  • Suffix Code 0: Basic type with standard feature set.
  • 3-Wire RTD Support: Eliminates lead wire resistance errors for accurate readings.
  • Channel Isolation: Each of the 12 channels is independently isolated from the system.
  • Burn-out Detection: Detects sensor or wiring failures and drives output UP or DOWN.
  • Dual-Redundant Ready: Supports system redundancy for critical temperature loops.

Frequently Asked Questions (FAQ)

  • Q: What RTD types does the AAR181-S50 support?
    A: The AAR181-S50 supports Pt100 (100 Ω at 0 °C) in a 3-wire configuration per JIS and IEC standards.
  • Q: How does the burn-out detection work on this module?
    A: You can set burn-out per module to UP or DOWN. The module detects an open circuit or broken sensor within 60 seconds.
  • Q: What is the total resistance limit for RTD wiring?
    A: The allowable total resistance per wire (including sensor and lead wires) is 40 Ω or less for guaranteed accuracy.
  • Q: Can I use this module with 2-wire RTD sensors?
    A: The AAR181-S50 is optimized for 3-wire connections. For 2-wire sensors, you must short the INA and INC terminals externally.
  • Q: What is the data update rate for temperature readings?
    A: The module updates all 12 channel data every 1 second in normal operation.
  • Q: Does this module support redundant system configurations?
    A: Yes, the AAR181-S50 works with Yokogawa's dual-redundant architecture for critical process loops.
  • Q: How do I compensate for accuracy when measuring below 0 °C?
    A: Multiply the specified RTD accuracy (±120 mΩ) by coefficient K based on the thermoelectromotive force ratio at the measured temperature.

Contact Information Inquiries: sales@nex-auto.com , +86 153 9242 9628

Partner NexAuto Technology Limited : https://www.nex-auto.com/

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most