Skip to product information
1 of 2

S30A-4111DP S3000 Safety Laser Scanner - SICK

In stock (16 units), ready to be shipped
  • Vendor:

    SICK

  • Type:

    Safety Laser Scanner

  • Country of Origin:

    DE

  • Dimensions:

    15*15*16cm

  • Weight:

    3000 g

  • Tags: Safety laser scanner

S30A-4111DP S3000 Safety Laser Scanner by SICK

Key Technical Specifications

  • Brand: SICK
  • Model: S30A-4111DP
  • Series: S3000
  • Part number: 1045651
  • Protective field range: 4 m
  • Maximum warning field range: 49 m
  • Distance measuring range: 49 m
  • Scan angle: 190°
  • Resolution: 30 mm, 40 mm, 50 mm, 70 mm, or 150 mm, configurable
  • Response time: 60 ms
  • Number of field sets: 8
  • Number of fields: 16
  • Number of monitoring cases: 16

Safety and Performance Data

  • Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061)
  • Category: Category 3 (EN ISO 13849)
  • Performance level: PL d (EN ISO 13849)
  • PFHd: 8.0 1E-08 (EN ISO 13849)
  • Mission time: 20 a (EN ISO 13849)
  • Type: Type 3 (IEC 61496)
  • Number of multiple samplings: Configurable 2 to 16
  • Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)

PROFINET and Network Properties

  • Port properties: Auto-negotiation, auto-crossover (MDIX), auto-polarity, 100Base-TX
  • Device properties: GSDML according to GSDML specification V2.25
  • PROFINET IO device: 2-port real-time switch according to PROFINET specification V2.2
  • PROFIsafe profile: 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4
  • Cycle time: 4, 8, 16, 32 ms, etc.
  • Conformance: Conformance Class B
  • Topology support: SNMP, MIB-2, LLDP according to IEEE 802.1AB, MRP client support
  • Switch properties: Filtering Data Base according to IEEE 802.1D, 6 prioritization levels for IEEE 802.1Q
  • Memory: 64 KB SRAM for caching telegrams, managed in 768-byte segments
  • Telegram extension: Based on "Cut-through"
  • Port status: Disabled, Blocking, Forwarding
  • Data transfer: Support for non-real-time and real-time data transfer

Functions and Configuration

  • Hazardous area protection (vertical): Supported
  • Hazardous area protection (horizontal): Supported
  • Access protection (vertical): Supported
  • Static protective field switching: Supported
  • Integrated configuration memory: Supported
  • Measured data output: Supported
  • External device monitoring (EDM): Not supported
  • Safe SICK device communication via EFI/SDL: Not supported
  • Expanded measured data output (CMS): Not supported
  • Static learning: Not supported
  • Multicast communication: Not supported
  • Supervisor AR: Not supported
  • MAC-pause mechanism in full duplex: Not supported
  • Back-pressure in half duplex: Not supported
  • Broadcast Storm Control: Not supported

Diagnostics and Interfaces

  • Configuration and diagnostics interface: RS-232
  • Configuration and diagnostics using CDS: TCP port 9000 and UDP port 30718, RS-232
  • Diagnostics: Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable
  • Report system errors: Supported
  • Cable diagnostics: Supported
  • Neighborhood alerts: Supported
  • Support for port statistics: Supported
  • I&M support: From I&M0 to I&M4
  • Electrical connection: Copper conductor (2 female connectors for RJ-45 push-pull plug), system plug with or without connecting cable
  • Incremental encoder inputs: None

FAQ

  • Q: What is the protective field range of the S30A-4111DP?
    A: The protective field range is 4 m, and the maximum warning field range is 49 m.
  • Q: How many protective fields can this scanner monitor at the same time?
    A: It monitors 2 protective fields simultaneously.
  • Q: What resolution options does this S3000 model support?
    A: You can configure 30 mm, 40 mm, 50 mm, 70 mm, or 150 mm resolution.
  • Q: What is the response time of the S30A-4111DP?
    A: The response time is 60 ms.
  • Q: What safety level does this scanner meet?
    A: It meets SIL2, SILCL2, Category 3, PL d, and Type 3 requirements.
  • Q: What is the ambient operating temperature range?
    A: The ambient operating temperature range is -10 °C to +50 °C.
  • Q: What is the enclosure rating?
    A: The enclosure rating is IP 65.
  • Q: How many field sets and monitoring cases does it support?
    A: It supports 8 field sets, 16 fields, and 16 monitoring cases.
  • Q: What network protocol does this scanner use?
    A: It uses PROFINET IO with PROFIsafe profile and 100Base-TX ports.
  • Q: What is the mission time?
    A: The mission time is 20 years according to EN ISO 13849.
  • Q: What shipping methods do you use?
    A: We ship by FedEx, UPS, and DHL.
  • Q: What is the return policy?
    A: We support 30-day returns.

Contact Information

Inquiries: sales@nex-auto.com
Phone/WhatsApp: +86 153 9242 9628

Partner NexAuto Technology Limited: https://www.nex-auto.com/

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most