Skip to product information
1 of 3

CC-PAIL51 Honeywell Low Level Analog Output Module

In stock (15 units), ready to be shipped
  • Vendor:

    Honeywell

  • Type:

    Digital Output Module

  • Country of Origin:

    USA

  • Dimensions:

    17*12*5cm

  • Weight:

    350 g

  • Tags: Digital output module

Honeywell CC-PAIL51 Low Level Analog Output Module – Technical Overview

Key Technical Specifications

  • Input Type: Thermocouple or RTD (user-configurable per channel).
  • Channels: 16-point input with full channel-to-channel and channel-to-power isolation.
  • Scan Rate: 1 second per channel for timely data acquisition.
  • Bandwidth: 0 to 4.7 Hz (-3 dB) for stable measurement.
  • Nominal TC Range: -20 to +100 millivolts; maximum continuous input (non-damaging): -10 to +10 V (TC) and -1 to +2 V @ 100 mA (RTD).
  • Gain Error: 0.050% full scale max for precise readings.
  • Temperature Stability: ±20 ppm per °C for both TC/mV and RTD inputs.
  • Long-Term Drift: 500 ppm ensures sustained performance over time.
  • Input Impedance: 1 megohm at DC (TC only).
  • Common Mode Voltage: ±250 VDC or VAC RMS with respect to power system common.
  • CMRR: 120 dB min at 50/60 Hz (with 1000 ohm source impedance).
  • Channel-to-Channel Voltage: ±250 VDC or VAC RMS, DC to 60 Hz.
  • Crosstalk: 80 dB (DC to 60 Hz); 120 dB at 50 and 60 Hz for minimal interference.
  • NMRR at 50/60 Hz: 60 dB min for effective noise rejection.
  • Line Frequency Integration: Fixed selection of 50 Hz or 60 Hz.
  • RTD Excitation Current: 1 milliampere.
  • Cold Junction Compensation: -20 to +60 °C (±0.5 °C typical).
  • TC Linearization Accuracy: ±0.05 Ω/°C.
  • Open TC Detection: ≤1000 Ω = guaranteed no-trip; ≥1500 Ω guaranteed trip.
  • RTD Max Lead Resistance: 15 Ω per lead.

Frequently Asked Questions (FAQ)

  • Q: Is the CC-PAIL51 a new or refurbished unit?
    A: We supply only brand new, factory-sealed Honeywell CC-PAIL51 modules.
  • Q: Can I configure each channel for different sensor types?
    A: Yes, you can set each input independently for TC, RTD, or millivolt.
  • Q: What is the maximum lead resistance for RTD connections?
    A: The CC-PAIL51 allows up to 15 Ω per lead for accurate RTD measurements.
  • Q: How does the open thermocouple detection work?
    A: It guarantees no-trip below 1000 Ω and trips above 1500 Ω per conversion.
  • Q: What is the module's operating temperature range?
    A: The unit operates reliably from -40 to +70 °C.
  • Q: Do you offer technical support for this Honeywell module?
    A: Yes, our team provides expert assistance for installation and configuration.
  • Q: What shipping carriers do you use?
    A: We ship globally via FedEx, UPS, and DHL with expedited options.

Contact Information: For inquiries, email us at sales@nex-auto.com or call +86 153 9242 9628 (WhatsApp).

Partner: NexAuto Technology Limited

Fast & Reliable Shipping

Quick worldwide delivery

keeps your automation projects on schedule.

Genuine & Trusted

All components are 100% authentic

ensuring reliable performance for your systems.

  • Express Delivery
  • 12 Months Warranty
  • 30 Days Easy Returns
View Product Details

Customer Support

Get Help When You Need It Most