Lewati ke informasi produk
1 dari 3

CI873A Communication Interface | AC 800M ABB

Tersedia (20 unit), siap untuk dikirim
  • Vendor:

    ABB

  • Tipe:

    Communication Interface Module

  • Country of Origin:

    SE

  • Dimensions:

    18*12*5cm

  • Weight:

    700 g

  • Tag: Communication interface

CI873A EtherNet/IP Communication Interface

The CI873A from ABB enables AC 800M controllers to communicate with industrial devices using EtherNet/IP protocol. This versatile communication interface supports both EtherNet/IP and DeviceNet protocols for flexible integration. It provides reliable connectivity for industrial automation and control systems.

Protocol and Communication Features

  • Implements EtherNet/IP protocol for industrial Ethernet communication
  • Supports DeviceNet protocol for additional connectivity options
  • Operates as a master controller in industrial network applications
  • Uses CH1 Ethernet connector supporting 100 Mbps transmission speed
  • Enables communication with various industrial Ethernet devices

Technical Specifications

  • Manufacturer: ABB
  • Model Number: CI873A (Article 3BSE092695R1)
  • Communication Protocol: EtherNet/IP and DeviceNet
  • Operation Mode: Master controller functionality
  • Transmission Speed: 10/100 Mbit/s auto-negotiating Ethernet
  • Network Connector: RJ-45 female (8-pin) on TP867 baseplate
  • Maximum CEX Bus Units: 12 modules per controller system
  • Power Consumption: 160 mA typical at 24V DC

System Requirements and Compatibility

  • Requires System 800xA version 6.0.3.3, 6.1.1 or later
  • Compatible with HI Controller systems for industrial applications
  • TP867 baseplate provides two RJ45 connectors (CH1 used for communication)
  • Contains CEX-Bus logic, communication unit, and DC/DC converter
  • Powered by +24V supply through the CEX-Bus connection
  • Supports up to 6 redundant pairs of CI873A modules from version 5.1 FP4

Performance and Reliability Features

  • Supports module redundancy for high-availability applications
  • Enables hot swap capability for maintenance without system interruption
  • Provides robust EtherNet/IP master functionality
  • Allows configuration of up to 6 redundant module pairs
  • Designed for reliable operation in demanding industrial environments

Environmental Specifications

  • Operating Temperature: +5 to +55 °C (+41 to +131 °F)
  • Storage Temperature: -40 to +70 °C (-40 to +158 °F)
  • Relative Humidity: 5 to 95% non-condensing
  • Maximum Altitude: 2000 meters according to IEC/EN 61131-2
  • Pollution Degree: Degree 2 per IEC/EN 61131-2 standards
  • Protection Rating: IP20 according to EN60529, IEC 529
  • Corrosion Protection: G3 compliance to ISA 71.04

Certifications and Compliance

  • CE marked for European market compliance
  • UL 61010-1 and UL 61010-2-201 for electrical safety
  • Hazardous location certification: UL 60079-15, cULus Class 1, Zone 2
  • AEx nA IIC T4, ExnA IIC T4Gc X for explosive atmospheres
  • Marine certificates: DNV-GL (with ABS, BV, LR pending)
  • RoHS compliance: DIRECTIVE/2011/65/EU (EN 50581:2012)
  • WEEE compliance: DIRECTIVE/2012/19/EU

Physical Dimensions

  • Width: 59 mm (2.3 inches)
  • Height: 185 mm (7.3 inches)
  • Depth: 127.5 mm (5.0 inches)
  • Weight: 700 g (1.5 pounds) including base unit

Installation and Configuration

  • Mount the module on TP867 baseplate in AC 800M controller rack
  • Connect Ethernet cable from CH1 port to industrial network switch
  • Configure EtherNet/IP parameters for master device operation
  • Set up module redundancy pairs if required for critical applications
  • Verify proper +24V power supply through CEX-Bus connection
  • Test communication with EtherNet/IP devices after installation

Frequently Asked Questions

  • What protocols does the CI873A support? It supports both EtherNet/IP and DeviceNet protocols.
  • How many redundant pairs are supported? It supports up to 6 redundant pairs of CI873A modules.
  • What is the operating mode? It operates as a master controller in the network.
  • What system software is required? It requires System 800xA version 6.0.3.3, 6.1.1 or later.
  • Which Ethernet port is used? Only the CH1 port is used for EtherNet/IP communication.

Pengiriman Cepat & Andal

Pengiriman cepat ke seluruh dunia

menjaga proyek otomatisasi Anda tepat waktu.

Asli & Terpercaya

Semua komponen 100% asli

menjamin kinerja yang andal untuk sistem Anda.

  • Pengiriman Ekspres
  • Garansi 12 Bulan
  • 30 Hari Pengembalian Mudah
Lihat Detail Produk

Dukungan Pelanggan

Dapatkan Bantuan Saat Anda Paling Membutuhkannya