PM857K02 Redundant AC 800M High Integrity Controller Package
The PM857K02 from ABB provides a complete redundant controller solution for critical automation applications. This package includes two PM857 processor units with all necessary components for high-availability operation. It delivers both process control and safety functionality up to SIL 3 when configured with safety modules.
Package Contents
- Two PM857K01 safety processor units for redundant operation
- One TK850 CEX-bus expansion cable for module connectivity
- One TK851 RCU-Link cable for redundant CPU communication
- Complete setup for immediate redundant system deployment
Controller Architecture and Features
- Dual PM857 processors with MPC866 microprocessors at 96 MHz
- Each unit contains 32 MB RAM with 22.184 MB for applications
- Integrated real-time clocks with lithium backup batteries
- Supports high-integrity functionality with SM812 safety modules
- CompactFlash interfaces for firmware management on both units
Technical Specifications
- Manufacturer: ABB
- Model Number: PM857K02 (Article 3BSE088386R1)
- Processor Type: Dual MPC866 at 96 MHz each
- Memory Capacity: 32 MB RAM per processor, 18 MB Flash PROM
- Performance: 0.17 ms for 1000 boolean operations per CPU
- I/O Capacity: Maximum 128 I/O signals in redundant configuration
- Switchover Time: Under 10 ms for seamless redundancy
Safety and Certification
- SIL 3 certified when used with SM812 safety modules
- TÜV approved for safety instrumented systems in redundant mode
- ISA Secure certified for cybersecurity protection
- IEC 61508 compliant redundant safety environment
- Enables high-availability safety and process control
Communication Interfaces
- Two RJ45 Ethernet ports per controller (CN1, CN2)
- Two RS-232C serial ports per unit (COM3, COM4)
- Supports MMS and IAC protocols over redundant networks
- 10 Mbit/s Ethernet speed with RJ-45 connectors
- Synchronized operation within 1 ms between controllers
Redundancy and High Availability
- Full CPU redundancy for continuous operation
- CEX-Bus redundancy for communication modules
- S800 I/O redundancy support for field devices
- Fast switchover under 10 ms for uninterrupted control
- Redundant power supply status monitoring
Power Requirements
- Power Supply: 24 V DC (19.2-30 V DC range)
- Power Consumption: 210 mA typical, 360 mA maximum per CPU
- Power Dissipation: 5.1 W per unit (8.6 W maximum)
- CEX Bus Supply: Maximum 2.4 A total current
- Modulebus Supply: 24V: 1.0A max, 5V: 1.5A max
Environmental Specifications
- Operating Temperature: +5 to +55 °C (+41 to +131 °F)
- Storage Temperature: -40 to +70 °C (-40 to +158 °F)
- Relative Humidity: 5 to 95% non-condensing
- Maximum Altitude: 2000 meters according to IEC/EN 61131-2
- Protection Rating: IP20 according to EN60529
- Vibration Resistance: Meets industrial vibration standards
Certifications and Compliance
- CE marked for European market compliance
- UL 61010-1 and UL 61010-2-201 for electrical safety
- cULus Class 1, Zone 2 for hazardous locations
- Marine certificates: ABS, BV, DNV-GL
- EMC: EN 61000-6-4, EN 61000-6-2
- RoHS compliance: EN 50581:2012
Physical Specifications
- Controller Dimensions: 119×186×135 mm per unit
- Package Weight: 2700 g (5.95 pounds) total
- Protection Class: IP20 for industrial environments
Installation and Configuration
- Configure with 800xA Control Builder engineering tool
- Follow Safety Manual requirements for SIL applications
- Connect RCU-Link cable between redundant processors
- Install CEX-bus expansion cable for module connectivity
- Use dual Ethernet ports for redundant network connections
- Monitor both units through LED indicators and INIT buttons
- Verify proper synchronization between redundant CPUs
Frequently Asked Questions
- What is included in the PM857K02 package? Two PM857 processors, CEX-bus cable, and RCU-Link cable.
- What safety level does it support? Up to SIL 3 with SM812 safety modules.
- What is the switchover time? Maximum 10 ms for seamless redundancy.
- How many I/O signals can it handle? Maximum 128 I/O signals in redundant mode.
- What engineering tool is used? 800xA Control Builder for configuration.
- Is network redundancy supported? Yes, through dual Ethernet ports on each controller.
شحن سريع وموثوق
توصيل سريع في جميع أنحاء العالم
يحافظ على مشاريع الأتمتة الخاصة بك في الموعد المحدد.
أصلي وموثوق
جميع المكونات أصلية 100%
مما يضمن أداءً موثوقًا لأنظمتك.
- التوصيل السريع
- ضمان 12 شهرًا
- 30 يومًا لإرجاع سهل

دعم العملاء
احصل على المساعدة عندما تحتاجها أكثر
هنا لمساعدتك في احتياجات الأتمتة الخاصة بك
اتصل بنا للحصول على الأسعار، تفاصيل المنتج، أو المساعدة في الطلب — خبراؤنا متاحون للمساعدة.
اعرف حقوقك في الإرجاع
لديك 30 يومًا لإرجاع المنتج إذا لم يلبي متطلباتك. راجع السياسة الكاملة للتفاصيل.