Allen-Bradley 1756-OB16I Output Module
Key Specifications
- Brand: Allen-Bradley
- Series: ControlLogix
- Model: 1756-OB16I
- Output Channels: 16 isolated points
- Voltage Range: 10-30V DC
- Current per Point: 2A @ 30°C / 1A @ 60°C
- Module Current: 8A @ 30°C / 4A @ 60°C
- Response Time ON: 1ms maximum
- Response Time OFF: 2ms maximum
- Power Dissipation: 3.6W maximum
- Isolation: 50V continuous
- Terminal Blocks: 1756-TBCH, 1756-TBS6H
Key Features & Benefits
- Individual Channel Isolation - Each output operates independently
- Configurable Safe States - Define output behavior during faults
- High Current Capacity - 2 amps per point at 30°C
- Fast Response Times - 1ms turn-on and 2ms turn-off maximum
- Flexible Wiring - Supports isolated and non-isolated schemes
- Visual Indicators - 16 integrated LEDs show channel status
- Wide Compatibility - Works with all 1756 ControlLogix chassis
Installation & Setup
- Slot Requirement: Single slot module for easy integration
- Terminal Blocks: Compatible with 1756-TBCH or 1756-TBS6H
- Chassis Support: Fits all 1756 local and remote chassis
- Power Requirements: 350mA @ 5.1V DC backplane current
- Fuse Protection: Recommended external 4A quick-acting fuses
- Wiring Options: Individual isolated or common source configurations
Performance Characteristics
- Current Rating: 2A per point at 30°C, derating to 1A at 60°C
- Total Capacity: 8A module total at 30°C, 4A at 60°C
- Surge Current: 4A for 10ms repeatable every 2 seconds
- Voltage Drop: 1.2V maximum at 2A load current
- Leakage Current: 0.5mA maximum off-state per point
- Minimum Load: 1mA per channel for proper operation
Safety & Protection
- Isolation Rating: 250V output-to-backplane continuous isolation
- Safe State Configuration: Programmable states for fault conditions
- LED Indicators: Individual channel status monitoring
- External Fusing: Support for 4A quick-acting fuses
- Inductive Load Protection: Recommended surge suppression devices
Application Examples
- Industrial Relays - Control contactors and motor starters
- Solenoid Valves - Actuate pneumatic and hydraulic systems
- Warning Devices - Operate sirens, horns, and strobe lights
- Indicator Systems - Drive pilot lamps and status displays
- Process Control - Manage actuators and positioning systems
Frequently Asked Questions
What makes the OB16I different from other output modules?
- The 1756-OB16I provides individual isolation for each output channel, allowing different voltage sources per output.
What current can each output handle?
- Each output supports 2 amps at 30°C, derating linearly to 1 amp at 60°C.
Are external fuses required?
- Yes, we recommend using 4A quick-acting fuses for output protection.
What are configurable safe states?
- You can define whether outputs stay on, turn off, or hold last state during program mode or controller faults.
What terminal blocks are compatible?
- Use 1756-TBCH or 1756-TBS6H 36-pin removable terminal blocks for wiring.
How fast does the module respond?
- Maximum response is 1ms for turn-on and 2ms for turn-off operations.
Can I use different voltage sources?
- Yes, individual isolation allows different 10-30V DC sources for each output.
For technical support and pricing information, contact our experts at: sales@nex-auto.com
شحن سريع وموثوق
توصيل سريع في جميع أنحاء العالم
يحافظ على مشاريع الأتمتة الخاصة بك في الموعد المحدد.
أصلي وموثوق
جميع المكونات أصلية 100%
مما يضمن أداءً موثوقًا لأنظمتك.
- التوصيل السريع
- ضمان 12 شهرًا
- 30 يومًا لإرجاع سهل

دعم العملاء
احصل على المساعدة عندما تحتاجها أكثر
هنا لمساعدتك في احتياجات الأتمتة الخاصة بك
اتصل بنا للحصول على الأسعار، تفاصيل المنتج، أو المساعدة في الطلب — خبراؤنا متاحون للمساعدة.
اعرف حقوقك في الإرجاع
لديك 30 يومًا لإرجاع المنتج إذا لم يلبي متطلباتك. راجع السياسة الكاملة للتفاصيل.