Bỏ qua thông tin sản phẩm
1 của 3

Allen-Bradley - 1746-NT4 Analog Input Module

Còn hàng (18 đơn vị), sẵn sàng để giao hàng
  • Nhà cung cấp:

    Allen-Bradley

  • Loại:

    Analog Input Module

  • Country of Origin:

    USA

  • Dimensions:

    13*15*4cm

  • Weight:

    500 g

  • Thẻ: Analog input module

Allen-Bradley 1746-NT4 Thermocouple/mV Input Module

  • Brand: Allen-Bradley
  • Series: SLC 500 programmable controller family
  • Model Number: 1746-NT4
  • Module Type: 4-channel Thermocouple/mV analog input
  • Input Channels: Four isolated thermocouple/mV inputs
  • Resolution: 16-bit input, 14-bit output conversion
  • A/D Conversion: Sigma-delta modulation method

Technical Performance Specifications

  • The 1746-NT4 provides four independent measurement channels
  • Update time is configurable from 26 milliseconds to 1.2 seconds
  • Step response time is 60 milliseconds in, 2.5 milliseconds out
  • Bandwidth ranges from 2.62 Hz to 65.5 Hz for signal filtering
  • Built-in cold-junction compensation (CJC) sensors maintain accuracy
  • Auto-calibration occurs at power-up and when channels enable
  • Five status LEDs indicate module operation and individual channel status
  • Selectable filter frequencies: 10 Hz, 50 Hz, 60 Hz, and 250 Hz

Sensor and Signal Compatibility

  • Thermocouple Types: Supports J, K, T, E, S, R, B, and N sensors
  • Millivolt Inputs: Compatible with ±50 mV and ±100 mV signals
  • Each channel features configurable open circuit detection settings
  • Open circuit response options: Zero, Upscale, or Downscale reading
  • For thermocouples: Use shielded twisted extension wire specifically designed
  • For mV signals: Recommended cable is Belden 8761 or equivalent
  • Maximum cable impedance: 25 ohms for proper signal transmission
  • Terminals accept two wires maximum at 2.5 mm (14 AWG) wire size

Electrical and Installation Specifications

  • Backplane current: 60 mA at 5V DC and 40 mA at 24V DC
  • Maximum power consumption: 0.8 watts total (0.3W at 5V DC, 0.5W at 24V DC)
  • No external power supply required - powered from backplane only
  • Install in any 1746 chassis slot except slot 0 (reserved for processor)
  • Compatible with both fixed style and modular style SLC 500 hardware
  • Block transfers required when used in remote I/O system configurations
  • Four channels are isolated from the backplane for signal integrity

Environmental and Operational Details

  • Operating temperature: 0°C to 60°C (32°F to 140°F)
  • Storage temperature: -40°C to 85°C (-40°F to 185°F)
  • Single-slot design maximizes space efficiency in control panels
  • Ideal for temperature monitoring in harsh industrial environments

Frequently Asked Questions

  • Where should I install this module in the chassis?
    Install the 1746-NT4 in any slot of a 1746 chassis except slot 0 for the processor.
  • Does the module need separate power wiring?
    No external power is needed - it receives power from the SLC 500 backplane connection.
  • How does cold-junction compensation work?
    Two built-in CJC sensors measure terminal temperature to compensate for reference junction effects.
  • What happens if a thermocouple wire breaks?
    Configurable open circuit detection can force readings to zero, upscale, or downscale values.

Contact Information:
For technical specifications or purchasing assistance:
Email: sales@nex-auto.com
Phone/WhatsApp: +86 153 9242 9628

Partner: NexAuto Technology Limited

Giao hàng nhanh chóng và đáng tin cậy

Giao hàng nhanh trên toàn thế giới

giúp các dự án tự động hóa của bạn đúng tiến độ.

Chính hãng & Đáng tin cậy

Tất cả các linh kiện đều là hàng chính hãng 100%

đảm bảo hiệu suất đáng tin cậy cho hệ thống của bạn.

  • Giao hàng nhanh
  • Bảo hành 12 tháng
  • 30 Ngày Đổi Trả Dễ Dàng
Xem chi tiết sản phẩm

Hỗ trợ khách hàng

Nhận trợ giúp khi bạn cần nhất