Allen-Bradley 1746-NR8 SLC 500 RTD Input Module | 8-Channel

Còn hàng (23 đơn vị), sẵn sàng để giao hàng
  • Nhà cung cấp:

    Allen-Bradley

  • Loại:

    Analog Input Module

  • Country of Origin:

    USA

  • Dimensions:

    13*15*4cm

  • Weight:

    500 g

  • Thẻ: Analog input module

Allen-Bradley 1746-NR8 RTD/Resistance Input Module

  • Brand: Allen-Bradley
  • Series: SLC 500 programmable controller family
  • Model Number: 1746-NR8
  • Module Type: 8-channel RTD/Resistance analog input
  • Input Channels: Eight isolated RTD/resistance inputs
  • Temperature Resolution: 0.01° Celsius precision
  • A/D Conversion: Sigma-delta modulation technology

Technical Performance Specifications

  • The 1746-NR8 provides eight independent measurement channels in one module
  • Update time is configurable from 6 milliseconds to 2 seconds per channel
  • It supports multiple RTD types including Platinum, Copper, Nickel, and Nickel Iron
  • Built-in programmable low-pass digital filtering reduces signal noise
  • Auto-calibration occurs at power-up and can cycle every 5 minutes
  • Step response time is 60 milliseconds in, 2.5 milliseconds out
  • Nine status LEDs indicate module operation and individual channel status
  • Broken sensor detection identifies open or short circuit conditions automatically

Sensor Compatibility and Wiring Options

  • Supported RTD Types: Platinum (385/3916), Copper (426), Nickel (618/672), Nickel Iron (518)
  • Wiring Configurations: Supports 2-wire, 3-wire, and 4-wire RTD connections
  • Direct Resistance Inputs: 0-150Ω, 0-300Ω, 0-500Ω, 0-1000Ω ranges available
  • Recommended cable: Belden 9501 for 2-wire, Belden 9533/83503 for 3/4-wire RTDs
  • Use lower gauge cables (like AWG #16) for long wire runs to maintain accuracy
  • Each Removable Terminal Block (RTB) terminal accepts single wire connections only
  • Compatible with Allen-Bradley 1746-RT-35 terminal block for field wiring

Electrical and Isolation Specifications

  • Backplane current: 100 mA at 5V DC and 55 mA at 24V DC
  • Maximum power consumption: 1.82 watts total (0.5W at 5V DC, 1.32W at 24V DC)
  • Isolation: 500V AC for 1 minute between inputs and backplane/chassis ground
  • Continuous isolation: 5V DC between individual measurement channels
  • Maximum common-mode voltage tolerance: ±1 volt
  • Maximum permanent overload protection: ±5V DC or ±5 mA
  • No external power supply required - powered entirely from backplane

Environmental and Installation Details

  • Operating temperature: 0°C to 60°C (32°F to 140°F)
  • Storage temperature: -40°C to 85°C (-40°F to 185°F)
  • Relative humidity: 5% to 95% non-condensing
  • Install in any 1746 chassis slot except slot 0 (reserved for processor)
  • Compatible with both fixed style and modular style SLC 500 hardware
  • Single-slot design maximizes channel density in control panels
  • Ideal for temperature monitoring and mechanical position sensing applications

Frequently Asked Questions

  • What is the measurement resolution for temperature readings?
    This module provides high precision with 0.01° Celsius resolution for accurate temperature monitoring.
  • Can I measure resistance values directly?
    Yes, the module accepts direct resistance inputs from 0-150Ω to 0-1000Ω for various applications.
  • Where should I install this module in the chassis?
    Install the 1746-NR8 in any slot of a 1746 chassis except slot 0, which is processor-only.
  • Does the module require separate power wiring?
    No external power is needed - the module receives power directly from the SLC 500 backplane.

Giao hàng nhanh chóng và đáng tin cậy

Giao hàng nhanh trên toàn thế giới

giúp các dự án tự động hóa của bạn đúng tiến độ.

Chính hãng & Đáng tin cậy

Tất cả các linh kiện đều là hàng chính hãng 100%

đảm bảo hiệu suất đáng tin cậy cho hệ thống của bạn.

  • Giao hàng nhanh
  • Bảo hành 12 tháng
  • 30 Ngày Đổi Trả Dễ Dàng
Xem chi tiết sản phẩm

Hỗ trợ khách hàng

Nhận trợ giúp khi bạn cần nhất