Allen-Bradley 1746-NR4 RTD/Resistance Input Module

  • Brand: Allen-Bradley
  • Series: SLC 500 programmable controller system
  • Model Number: 1746-NR4
  • Module Type: 4-channel RTD/Resistance analog input
  • Input Channels: Four isolated RTD/resistance inputs
  • A/D Conversion: Sigma-delta modulation method
  • Temperature Resolution: 0.01° Celsius

Technical Performance Specifications

  • The 1746-NR4 module provides four independent input channels
  • It supports multiple RTD types including Platinum, Copper, Nickel, and Nickel Iron
  • Measurement range covers from -200°C to 850°C for temperature sensing
  • Update time is configurable between 17 milliseconds and 1.2 seconds per channel
  • Bandwidth ranges from 2.62 Hz to 65.5 Hz with programmable low-pass digital filtering
  • The module features automatic self-calibration when parameters change
  • Built-in broken sensor detection identifies open or short circuit conditions
  • Five status LEDs provide module and individual channel health indication

Sensor and Input Compatibility

  • Platinum RTDs: 385 and 3916 curves with 100, 200, 500, 1000 ohm values
  • Copper RTDs: 426 curve with 10 ohm resistance
  • Nickel RTDs: 618 and 672 curves with 120 ohm resistance
  • Nickel Iron RTDs: 518 curve with 604 ohm resistance
  • Direct Resistance Inputs: 0-150Ω, 0-300Ω, 0-500Ω, 0-1000Ω ranges
  • Resistance inputs measure displacement, position, or other process variables
  • The module provides proper excitation current for all connected sensors

Electrical and Safety Specifications

  • Backplane current requirement is 50 mA at both 5V DC and 24V DC
  • Maximum power consumption measures only 1.5 watts total
  • Isolation rating is 500V DC for 1 minute between inputs and backplane
  • Maximum common-mode voltage tolerance is ±1 volt
  • Maximum permanent overload protection: ±5V DC or ±5 mA
  • No external power supply needed - powered entirely from backplane
  • Step response time is 60 milliseconds in, 2.5 milliseconds out

Environmental and Installation Details

  • Operating temperature range is 0°C to 60°C (32°F to 140°F)
  • Storage temperature range is -40°C to 85°C (-40°F to 185°F)
  • Install in any 1746 chassis slot except slot 0 (reserved for processor)
  • Compatible with fixed style and modular style SLC 500 hardware
  • Works with 1746-A2 expansion chassis for system flexibility
  • Supports both local chassis and remote I/O configurations
  • Compact design saves valuable control panel space

Packaging and Shipping Information

  • Every 1746-NR4 module ships as new and factory original
  • All items come complete in manufacturer packaging with documentation
  • We maintain stock for immediate shipment after order confirmation
  • Standard processing and shipping time is within 5 business days
  • Available shipping carriers include FedEx, UPS, and DHL services
  • Return policy accepts qualified returns within 30 days of delivery

Frequently Asked Questions

  • What sensors work with the 1746-NR4 module?
    The 1746-NR4 supports Platinum, Copper, Nickel, and Nickel Iron RTDs, plus direct resistance inputs up to 1000 ohms.
  • How many temperature sensors can I connect?
    You can connect up to four separate RTD sensors, one to each of the module's input channels.
  • What is the temperature measurement resolution?
    This module provides high precision with 0.01° Celsius resolution for accurate temperature monitoring.
  • Can I measure resistance directly without RTDs?
    Yes, the module accepts direct resistance inputs in ranges from 0-150Ω to 0-1000Ω for various applications.
  • Where do I install this module in the chassis?
    Install the 1746-NR4 in any slot of a 1746 chassis except slot 0, which is for the processor only.
  • Does the module need separate power wiring?
    No, the module receives all necessary power directly from the SLC 500 backplane connection.
  • How does the module handle sensor failures?
    Built-in diagnostics detect open or shorted sensors and report these conditions to the controller.

จัดส่งรวดเร็วและเชื่อถือได้

จัดส่งทั่วโลกอย่างรวดเร็ว

ช่วยให้โครงการระบบอัตโนมัติของคุณเป็นไปตามกำหนดเวลา

แท้และเชื่อถือได้

ชิ้นส่วนทั้งหมดเป็นของแท้ 100%

เพื่อให้มั่นใจในประสิทธิภาพที่เชื่อถือได้สำหรับระบบของคุณ

  • จัดส่งด่วน
  • รับประกัน 12 เดือน
  • คืนสินค้าได้ง่ายภายใน 30 วัน
ดูรายละเอียดผลิตภัณฑ์

ฝ่ายสนับสนุนลูกค้า

รับความช่วยเหลือเมื่อคุณต้องการมากที่สุด