Honeywell 900K01-0201 Pulse/Frequency/Quadrature Module
The 900K01-0201 is a versatile 4-channel signal interface module for the Honeywell HC900 controller. Each channel can be configured as a high-speed pulse input, frequency input, or pulse output, providing flexible motion and flow measurement control.
Core System Specifications
- Brand: Honeywell
- Model Number: 900K01-0201
- Product Type: Pulse/Frequency/Quadrature Module
- Channels per Module: 4 (Individually Configurable)
- Channel Functions: Pulse Input, Frequency Input, or Pulse Output (per channel)
- Input/Output Voltage Range: 0 VDC to 24 VDC
- Digital Output Type: Open Collector
- Digital Output Rating: 5 to 24V, 30 mA Maximum
- Module Status LED: Green Blinking (Active Scan), Red (Fault/Diagnostic)
- Note: Quadrature signal decoding is not supported in the current release.
Pulse Input Specifications
- Input Voltage Range: 0 to 24 VDC
- ON Voltage Level: 3.0 VDC Minimum
- OFF Voltage Level: 1.0 VDC Maximum
- Input Impedance: 25 kΩ
- Maximum Frequency: 10 kHz
- Minimum Pulse Width: 3 µs
- Counter Resolution: 32-bit
- Preset Value: User-configurable (within 32-bit range)
-
Preset Action: Configurable as ON or OFF in HC Designer:
- ON: Digital output turns ON for 1 second when preset is reached.
- OFF: Digital output latches ON until a counter reset command.
- Counter Behavior at Preset: Auto-reset and continue (Preset Action ON) or count beyond preset (Preset Action OFF).
- Counter HOLD: Enabled via I/O data type in ControlEdge Builder.
- Counter RESET: Via OFF-to-ON transition on RST input in ControlEdge Builder.
- Status Flags: OVERFLOW flag (STS=33) on counter overflow; PREI flag when digital output activates.
Frequency Input Specifications
- Input Voltage Range: 0 to 24 VDC
- ON Voltage Level: 3.0 VDC Minimum
- OFF Voltage Level: 1.0 VDC Maximum
- Input Impedance: 25 kΩ
- Frequency Range: 10 Hz Minimum, 100 kHz Maximum
-
Minimum Pulse Width:
- 500 µs (10 Hz to 500 Hz)
- 50 µs (10 Hz to 5 kHz)
- 2.5 µs (10 Hz to 100 kHz)
- Digital Output: Turns ON if measured frequency is out of configured range.
Pulse Output Specifications
- Channel Usage: Any single channel can be used for Pulse Output (disables input functions on that channel).
- Output Type: Open Collector
- Output Rating: 5 to 24V, 30 mA Maximum
- Frequency Range: 25 Hz to 10 kHz
- Duty Cycle: Fixed at 50%
- Output Mode: Selectable as CONTINUOUS or a specific NUMBER OF PULSES.
Module Features & Applications
- Multi-function channels reduce inventory needs by covering pulse counting, frequency monitoring, and pulse generation.
- High-speed 32-bit counter is suitable for totalizing flow meters, rotary encoders, and production batch counting.
- Open-collector output allows interfacing with a wide range of external devices (e.g., panel meters, other controllers).
- Programmable preset actions enable automatic control responses based on counted values.
- Frequency input with out-of-range detection is ideal for monitoring turbine flow meters or motor speeds for alarm conditions.
- Pulse output function can generate precise pulse trains for stepper motor drivers or as a simulated sensor signal.
For configuration examples or to order the Honeywell 900K01-0201, contact our engineering team.
Contact: Email sales@nex-auto.com or WhatsApp +86 153 9242 9628.
Partner: NexAuto Technology Limited
© 2026 AutoNex Controls Limited. All rights reserved.
Fast & Reliable Shipping
Quick worldwide delivery
keeps your automation projects on schedule.
Genuine & Trusted
All components are 100% authentic
ensuring reliable performance for your systems.
- Express Delivery
- 12 Months Warranty
- 30 Days Easy Returns

Customer Support
Get Help When You Need It Most
Here to Assist Your Automation Needs
Contact us for pricing, product details, or order assistance — our experts are available to help.
Know Your Return Rights
You have 30 days to return a product if it doesn’t meet your requirements. See the full policy for details.