Home
Allen-Bradley - 1746-NT4 Analog Input Module
1
/
di
3
Allen-Bradley - 1746-NT4 Analog Input Module
No reviews
Disponibile (18 unità), pronto per essere spedito
-
Venditore:
Allen-Bradley
-
Tipo:
Analog Input Module
-
Country of Origin:
USA
-
Dimensions:
13*15*4cm
- Weight:
500 g
- Tag: Analog input module
Allen-Bradley 1746-NT4 Thermocouple/mV Input Module
- Brand: Allen-Bradley
- Series: SLC 500 programmable controller family
- Model Number: 1746-NT4
- Module Type: 4-channel Thermocouple/mV analog input
- Input Channels: Four isolated thermocouple/mV inputs
- Resolution: 16-bit input, 14-bit output conversion
- A/D Conversion: Sigma-delta modulation method
Technical Performance Specifications
- The 1746-NT4 provides four independent measurement channels
- Update time is configurable from 26 milliseconds to 1.2 seconds
- Step response time is 60 milliseconds in, 2.5 milliseconds out
- Bandwidth ranges from 2.62 Hz to 65.5 Hz for signal filtering
- Built-in cold-junction compensation (CJC) sensors maintain accuracy
- Auto-calibration occurs at power-up and when channels enable
- Five status LEDs indicate module operation and individual channel status
- Selectable filter frequencies: 10 Hz, 50 Hz, 60 Hz, and 250 Hz
Sensor and Signal Compatibility
- Thermocouple Types: Supports J, K, T, E, S, R, B, and N sensors
- Millivolt Inputs: Compatible with ±50 mV and ±100 mV signals
- Each channel features configurable open circuit detection settings
- Open circuit response options: Zero, Upscale, or Downscale reading
- For thermocouples: Use shielded twisted extension wire specifically designed
- For mV signals: Recommended cable is Belden 8761 or equivalent
- Maximum cable impedance: 25 ohms for proper signal transmission
- Terminals accept two wires maximum at 2.5 mm (14 AWG) wire size
Electrical and Installation Specifications
- Backplane current: 60 mA at 5V DC and 40 mA at 24V DC
- Maximum power consumption: 0.8 watts total (0.3W at 5V DC, 0.5W at 24V DC)
- No external power supply required - powered from backplane only
- Install in any 1746 chassis slot except slot 0 (reserved for processor)
- Compatible with both fixed style and modular style SLC 500 hardware
- Block transfers required when used in remote I/O system configurations
- Four channels are isolated from the backplane for signal integrity
Environmental and Operational Details
- Operating temperature: 0°C to 60°C (32°F to 140°F)
- Storage temperature: -40°C to 85°C (-40°F to 185°F)
- Single-slot design maximizes space efficiency in control panels
- Ideal for temperature monitoring in harsh industrial environments
Frequently Asked Questions
-
Where should I install this module in the chassis?
Install the 1746-NT4 in any slot of a 1746 chassis except slot 0 for the processor. -
Does the module need separate power wiring?
No external power is needed - it receives power from the SLC 500 backplane connection. -
How does cold-junction compensation work?
Two built-in CJC sensors measure terminal temperature to compensate for reference junction effects. -
What happens if a thermocouple wire breaks?
Configurable open circuit detection can force readings to zero, upscale, or downscale values.
Contact Information:
For technical specifications or purchasing assistance:
Email: sales@nex-auto.com
Phone/WhatsApp: +86 153 9242 9628
Partner: NexAuto Technology Limited
Spedizione Veloce e Affidabile
Consegna rapida in tutto il mondo
mantiene i tuoi progetti di automazione nei tempi previsti.
Autentico e Affidabile
Tutti i componenti sono 100% autentici
garantendo prestazioni affidabili per i tuoi sistemi.
- Consegna Espressa
- 12 Mesi di Garanzia
- Reso facile entro 30 giorni

Assistenza Clienti
Ricevi aiuto quando ne hai più bisogno
Qui per assisterti con le tue esigenze di automazione
Contattaci per prezzi, dettagli sul prodotto o assistenza per l'ordine — i nostri esperti sono disponibili per aiutarti.
Conosci i tuoi diritti di reso
Hai 30 giorni per restituire un prodotto se non soddisfa le tue esigenze. Consulta la politica completa per i dettagli.