Home
Allen-Bradley 1734-485ASC Serial Interface Module
1
/
از
3
Allen-Bradley 1734-485ASC Serial Interface Module
No reviews
موجود در انبار ({19} واحد)، آماده برای ارسال
-
Vendor:
Allen-Bradley
-
Type:
Serial Interface Module
-
Country of Origin:
USA
-
Dimensions:
5.6*1.2*7.5cm
- Weight:
500 g
- Tags: Serial interface module
Allen-Bradley 1734-485ASC Serial Interface Module
Core Technical Specifications
- Brand & Manufacturer: Allen-Bradley.
- Series & Model: POINT I/O series, model 1734-485ASC.
- Module Type: Dedicated Serial Interface Module (Key Switch Position 2).
- Electrical Ratings: Operates on 24V DC nominal power (10-28.8V DC range), consuming only 15mA.
- Network Support: Compatible with both 2-wire RS-485 and 4-wire RS-422 standards.
- Noise Immunity: Designed for use with shielded cable to minimize signal disruption from electrical noise.
Installation and Wiring Instructions
- You must use shielded cables for all network connections to ensure signal integrity.
- Ground the cable shield at one end only to avoid creating a ground loop fault.
- The 1734-485ASC terminal block does not have a chassis ground point. Connect the shield directly to the grounded DIN rail.
- Wire the network cables to the clearly marked positions on the 1734-TB terminal block.
Configuration and Operational Data
- The module uses default I/O message and buffer sizes, often set to 20 bytes each.
- You can easily modify these buffer sizes in the configuration file for longer data strings.
- Data flows from a DeviceNet master to the 1734-485ASC module, then to the serial device.
- Transmission triggers after receiving the set byte count or the End-of-String Terminator character.
Frequently Asked Questions (FAQ)
-
Q: What is the main function of the 1734-485ASC module?
A: The 1734-485ASC provides a serial interface to connect RS-232/422/485 ASCII devices to a DeviceNet network. -
Q: How should I handle cable shielding for this module?
A: Use shielded cable and ground the shield at the DIN rail only. Do not ground both ends or connect to logic common. -
Q: Can I adjust the data buffer size on this POINT I/O module?
A: Yes, the default is 20 bytes, but you can reconfigure the ASCII buffer size in the software for larger messages. -
Q: What power input does the module accept?
A: It accepts a 24V DC nominal supply, within a 10-28.8V DC range.
Contact Information Inquiries: sales@nex-auto.com or message us on WhatsApp: +86 153 9242 9628. Partner NexAuto Technology Limited : https://www.nex-auto.com/
حمل و نقل سریع و قابل اعتماد
تحویل سریع در سراسر جهان
پروژههای اتوماسیون شما را طبق برنامه نگه میدارد.
اصیل و مورد اعتماد
تمام قطعات ۱۰۰٪ اصل هستند
اطمینان از عملکرد قابل اعتماد برای سیستمهای شما.
- تحویل فوری
- ۱۲ ماه گارانتی
- بازگشت آسان در ۳۰ روز

پشتیبانی مشتریان
دریافت کمک زمانی که بیشترین نیاز را دارید
اینجا برای کمک به نیازهای اتوماسیون شما هستیم
برای قیمتگذاری، جزئیات محصول یا کمک در سفارش با ما تماس بگیرید — کارشناسان ما آماده کمک هستند.
حقوق بازگشت خود را بدانید
شما ۳۰ روز فرصت دارید تا محصول را بازگردانید اگر با نیازهای شما مطابقت نداشته باشد. برای جزئیات، سیاست کامل را ببینید.