Allen-Bradley 1746-NR4 RTD/Resistance Input Module

  • Brand: Allen-Bradley
  • Series: SLC 500 programmable controller system
  • Model Number: 1746-NR4
  • Module Type: 4-channel RTD/Resistance analog input
  • Input Channels: Four isolated RTD/resistance inputs
  • A/D Conversion: Sigma-delta modulation method
  • Temperature Resolution: 0.01° Celsius

Technical Performance Specifications

  • The 1746-NR4 module provides four independent input channels
  • It supports multiple RTD types including Platinum, Copper, Nickel, and Nickel Iron
  • Measurement range covers from -200°C to 850°C for temperature sensing
  • Update time is configurable between 17 milliseconds and 1.2 seconds per channel
  • Bandwidth ranges from 2.62 Hz to 65.5 Hz with programmable low-pass digital filtering
  • The module features automatic self-calibration when parameters change
  • Built-in broken sensor detection identifies open or short circuit conditions
  • Five status LEDs provide module and individual channel health indication

Sensor and Input Compatibility

  • Platinum RTDs: 385 and 3916 curves with 100, 200, 500, 1000 ohm values
  • Copper RTDs: 426 curve with 10 ohm resistance
  • Nickel RTDs: 618 and 672 curves with 120 ohm resistance
  • Nickel Iron RTDs: 518 curve with 604 ohm resistance
  • Direct Resistance Inputs: 0-150Ω, 0-300Ω, 0-500Ω, 0-1000Ω ranges
  • Resistance inputs measure displacement, position, or other process variables
  • The module provides proper excitation current for all connected sensors

Electrical and Safety Specifications

  • Backplane current requirement is 50 mA at both 5V DC and 24V DC
  • Maximum power consumption measures only 1.5 watts total
  • Isolation rating is 500V DC for 1 minute between inputs and backplane
  • Maximum common-mode voltage tolerance is ±1 volt
  • Maximum permanent overload protection: ±5V DC or ±5 mA
  • No external power supply needed - powered entirely from backplane
  • Step response time is 60 milliseconds in, 2.5 milliseconds out

Environmental and Installation Details

  • Operating temperature range is 0°C to 60°C (32°F to 140°F)
  • Storage temperature range is -40°C to 85°C (-40°F to 185°F)
  • Install in any 1746 chassis slot except slot 0 (reserved for processor)
  • Compatible with fixed style and modular style SLC 500 hardware
  • Works with 1746-A2 expansion chassis for system flexibility
  • Supports both local chassis and remote I/O configurations
  • Compact design saves valuable control panel space

Packaging and Shipping Information

  • Every 1746-NR4 module ships as new and factory original
  • All items come complete in manufacturer packaging with documentation
  • We maintain stock for immediate shipment after order confirmation
  • Standard processing and shipping time is within 5 business days
  • Available shipping carriers include FedEx, UPS, and DHL services
  • Return policy accepts qualified returns within 30 days of delivery

Frequently Asked Questions

  • What sensors work with the 1746-NR4 module?
    The 1746-NR4 supports Platinum, Copper, Nickel, and Nickel Iron RTDs, plus direct resistance inputs up to 1000 ohms.
  • How many temperature sensors can I connect?
    You can connect up to four separate RTD sensors, one to each of the module's input channels.
  • What is the temperature measurement resolution?
    This module provides high precision with 0.01° Celsius resolution for accurate temperature monitoring.
  • Can I measure resistance directly without RTDs?
    Yes, the module accepts direct resistance inputs in ranges from 0-150Ω to 0-1000Ω for various applications.
  • Where do I install this module in the chassis?
    Install the 1746-NR4 in any slot of a 1746 chassis except slot 0, which is for the processor only.
  • Does the module need separate power wiring?
    No, the module receives all necessary power directly from the SLC 500 backplane connection.
  • How does the module handle sensor failures?
    Built-in diagnostics detect open or shorted sensors and report these conditions to the controller.

Sürətli və Etibarlı Çatdırılma

Sürətli dünya üzrə çatdırılma

avtomatlaşdırma layihələrinizin vaxtında tamamlanmasını təmin edir.

Orijinal və Etibarlı

Bütün komponentlər 100% orijinaldır

sistemləriniz üçün etibarlı performansı təmin edir.

  • Sürətli Çatdırılma
  • 12 Ay Zəmanət
  • 30 Gün Asan Qaytarma
Məhsul Təfərrüatlarını Baxın

Müştəri Dəstəyi

Ən çox ehtiyacınız olan zaman kömək alın