{"product_id":"voltage-output-module-ge-fanuc-emerson-ic694mdl916","title":"Voltage Output Module GE Fanuc Emerson IC694MDL916","description":"\u003ch2\u003eGE Fanuc IC694MDL916 16-Channel Relay Output Module\u003c\/h2\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eModel: \u003cspan style=\"color: #ff0000;\"\u003eIC694MDL916\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOutput channels: \u003cspan style=\"color: #ff0000;\"\u003e16\u003c\/span\u003e isolated Form A (Normally Open)\u003c\/li\u003e\n\u003cli\u003eAC switching voltage: \u003cspan style=\"color: #0000ff;\"\u003e5 to 250 VAC\u003c\/span\u003e (47-63 Hz)\u003c\/li\u003e\n\u003cli\u003eDC switching voltage: \u003cspan style=\"color: #008000;\"\u003e0 to 125 VDC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum current rating: \u003cspan style=\"color: #800080;\"\u003e4 A\u003c\/span\u003e per contact\u003c\/li\u003e\n\u003cli\u003eMinimum current requirement: \u003cspan style=\"color: #ffa500;\"\u003e10 mA\u003c\/span\u003e per contact\u003c\/li\u003e\n\u003cli\u003eSwitching rate capacity: \u003cspan style=\"color: #008080;\"\u003e20 cycles per minute\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eResponse time: \u003cspan style=\"color: #a52a2a;\"\u003e10 ms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eIsolation rating: \u003cspan style=\"color: #000080;\"\u003e1500 VAC for 1 minute\u003c\/span\u003e (field to backplane)\u003c\/li\u003e\n\u003cli\u003eMechanical contact life: \u003cspan style=\"color: #800000;\"\u003e200,000 to 1,000,000 operations\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eBackplane current: \u003cspan style=\"color: #808000;\"\u003e300 mA at 5 VDC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOperating temperature: \u003cspan style=\"color: #808080;\"\u003e-20 to +60 °C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHumidity range: \u003cspan style=\"color: #000000;\"\u003e5 to 95% RH\u003c\/span\u003e non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this module a genuine GE Fanuc product?\u003c\/strong\u003e Yes, we supply only \u003cstrong\u003ebrand new original\u003c\/strong\u003e \u003cstrong\u003eIC694MDL916\u003c\/strong\u003e modules. All units come directly from authorized sources.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many relay contacts does this module have?\u003c\/strong\u003e The \u003cstrong\u003eIC694MDL916\u003c\/strong\u003e provides \u003cspan style=\"color: #ff0000;\"\u003e16\u003c\/span\u003e fully isolated Form A relay contacts. Each contact is normally open.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your shipping and handling time?\u003c\/strong\u003e We process and ship all available orders within \u003cstrong\u003e5 business days\u003c\/strong\u003e. You will receive tracking details promptly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich carriers do you use for shipping?\u003c\/strong\u003e We typically ship using major carriers including \u003cstrong\u003eDHL, FedEx, and UPS\u003c\/strong\u003e. We choose the best option for your location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your returns policy?\u003c\/strong\u003e We offer a \u003cstrong\u003e30-day return policy\u003c\/strong\u003e for all products. Please contact our sales team to initiate any returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat types of loads can this module switch?\u003c\/strong\u003e This module can switch both AC loads up to \u003cspan style=\"color: #0000ff;\"\u003e250 VAC\u003c\/span\u003e and DC loads up to \u003cspan style=\"color: #008000;\"\u003e125 VDC\u003c\/span\u003e. It handles various industrial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does 1500VAC isolation provide?\u003c\/strong\u003e This high isolation voltage protects the backplane from field-side transients. It ensures system reliability and safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum current per relay?\u003c\/strong\u003e Each relay contact can handle up to \u003cspan style=\"color: #800080;\"\u003e4 A\u003c\/span\u003e maximum current. This suits most industrial load requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical specifications and pricing, contact us at: \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139289440417,"sku":"IC694MDL916","price":206.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC694MDL916.jpg?v=1761638275","url":"https:\/\/www.autonexcontrol.com\/vi\/products\/voltage-output-module-ge-fanuc-emerson-ic694mdl916","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}