{"product_id":"mixed-i-o-module-ge-fanuc-ic200mdd849","title":"Mixed I\/O Module GE Fanuc IC200MDD849","description":"\u003ch2\u003eGE Fanuc IC200MDD849: Essential Control for Modern Automation\u003c\/h2\u003e\n\u003ch3\u003eCore Product Identity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line\u003c\/strong\u003e: Versamax Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number\u003c\/strong\u003e: \u003cstrong\u003eIC200MDD849\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type\u003c\/strong\u003e: Discrete Mixed I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Capacity\u003c\/strong\u003e: \u003cspan style=\"color: #c0392b;\"\u003e16 I\/O Points\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput\/Output Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2980b9;\"\u003e8 Positive Logic Inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eVoltage Range: 0-132 V AC\u003c\/li\u003e\n\u003cli\u003eNominal Voltage: \u003cspan style=\"color: #2980b9;\"\u003e120 V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eFrequency: 47-63 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Specifications\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #27ae60;\"\u003e8 Relay\/Common Outputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eCurrent Rating: \u003cspan style=\"color: #c0392b;\"\u003e2 A Maximum\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDC Voltage: 0-125 V DC\u003c\/li\u003e\n\u003cli\u003eAC Voltage: 0-265 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Architecture\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Construction\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eForm A Contact Configuration\u003c\/li\u003e\n\u003cli\u003eSilver Contact Material\u003c\/li\u003e\n\u003cli\u003eMoving Armature Mechanism\u003c\/li\u003e\n\u003cli\u003eIsolated Output Design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower Management\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBackplane Voltage: \u003cspan style=\"color: #f39c12;\"\u003e5 V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum Current: \u003cspan style=\"color: #f39c12;\"\u003e295 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNo Built-in Protection Circuits\u003c\/li\u003e\n\u003cli\u003eExternal Protection Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Environment\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Compatibility\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStandard 120V Industrial Systems\u003c\/li\u003e\n\u003cli\u003eBoth AC and DC Load Support\u003c\/li\u003e\n\u003cli\u003e47-63 Hz Frequency Range\u003c\/li\u003e\n\u003cli\u003eVersamax Platform Integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVersamax Rack Mounting\u003c\/li\u003e\n\u003cli\u003eExternal Fusing Recommended\u003c\/li\u003e\n\u003cli\u003eStandard Industrial Wiring\u003c\/li\u003e\n\u003cli\u003eNo Special Tools Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Characteristics\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage: 0-132 V AC\u003c\/li\u003e\n\u003cli\u003eOutput Current: 2 A Maximum\u003c\/li\u003e\n\u003cli\u003eOperating Frequency: 47-63 Hz\u003c\/li\u003e\n\u003cli\u003eIsolation: Output Channel Separation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Construction\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSilver Contact Reliability\u003c\/li\u003e\n\u003cli\u003eMoving Armature Durability\u003c\/li\u003e\n\u003cli\u003eIndustrial Grade Components\u003c\/li\u003e\n\u003cli\u003eCompact Form Factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImplementation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect Versamax Backplane Connection\u003c\/li\u003e\n\u003cli\u003eStandard Industrial Wiring Practices\u003c\/li\u003e\n\u003cli\u003eExternal Protection Device Installation\u003c\/li\u003e\n\u003cli\u003eQuick Commissioning Process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Considerations\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo Internal Fusing Provided\u003c\/li\u003e\n\u003cli\u003eExternal Snubbers Recommended\u003c\/li\u003e\n\u003cli\u003eMOV Protection Suggested\u003c\/li\u003e\n\u003cli\u003eRegular Maintenance Advised\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQuick Reference Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Points\u003c\/strong\u003e: \u003cspan style=\"color: #c0392b;\"\u003e16 I\/O\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type\u003c\/strong\u003e: Positive Logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type\u003c\/strong\u003e: Relay\/Common\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity\u003c\/strong\u003e: 2 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Support\u003c\/strong\u003e: 120V Nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Need\u003c\/strong\u003e: 5V @ 295mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Implementation Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat protection features are missing?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eIC200MDD849\u003c\/strong\u003e requires external fuses, snubbers, and MOVs for complete circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the relay contact material?\u003c\/strong\u003e\u003cbr\u003eAll outputs use \u003cstrong\u003esilver contacts\u003c\/strong\u003e with moving armature mechanism for reliable switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat voltage systems does it support?\u003c\/strong\u003e\u003cbr\u003eIt handles \u003cspan style=\"color: #2980b9;\"\u003e120V nominal\u003c\/span\u003e systems with 0-132V AC input and 0-265V AC\/0-125V DC output ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow much backplane power is needed?\u003c\/strong\u003e\u003cbr\u003eThe module requires \u003cspan style=\"color: #f39c12;\"\u003e5V at 295mA maximum\u003c\/span\u003e from the Versamax backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the output current limit?\u003c\/strong\u003e\u003cbr\u003eEach output channel can handle up to \u003cspan style=\"color: #c0392b;\"\u003e2 A\u003c\/span\u003e with proper external protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs stock readily available?\u003c\/strong\u003e\u003cbr\u003eWe maintain \u003cstrong\u003egenuine GE Fanuc\u003c\/strong\u003e inventory for immediate shipment within five business days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eContact our technical team for application assistance:\u003c\/em\u003e \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139264766113,"sku":"IC200MDD849","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC200MDD849.jpg?v=1763621060","url":"https:\/\/www.autonexcontrol.com\/vi\/products\/mixed-i-o-module-ge-fanuc-ic200mdd849","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}