{"product_id":"honeywell-fs-sdo-04110-110v-dc-safety-output","title":"Honeywell FS-SDO-04110 110V DC Safety Output","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell FS-SDO-04110 Safe Digital Output Module Introduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eHoneywell FS-SDO-04110\u003c\/span\u003e\u003c\/strong\u003e is a high-voltage safe digital output module specifically designed for safety instrumented systems (SIS). It provides reliable switching for 110V DC loads with built-in safety diagnostics.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eFS-SDO-04110\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Safe Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e TÜV certified for \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eSIL 3 \/ PLe\u003c\/span\u003e\u003c\/strong\u003e according to IEC 61508:2010\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 4 independent output channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 110 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Continuous Current:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003e0.32 A\u003c\/span\u003e\u003c\/strong\u003e per channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Safety Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Solid-state, short-circuit and overload protected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e 35 W per channel (110Vdc × 0.32A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current (Off-state):\u003c\/strong\u003e ≤ 2 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e ≤ 15 ms (ON to OFF or OFF to ON)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Coverage (DC):\u003c\/strong\u003e \u0026gt; 90%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMean Time To Failure (MTTFd):\u003c\/strong\u003e \u0026gt; 100 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 5Vdc: 80 mA, 24Vdc: 120 mA (typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Dimensions:\u003c\/strong\u003e 45 mm × 120 mm × 115 mm (W × H × D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard 35 mm DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Removable screw-clamp terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size:\u003c\/strong\u003e 0.5 - 2.5 mm² (AWG 20-14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.6 Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication \u0026amp; System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for switching 110V DC safety-critical loads such as solenoid valves, motor starters, and alarm circuits\u003c\/li\u003e\n\u003cli\u003eIdeal for oil \u0026amp; gas, chemical processing, and power generation safety systems\u003c\/li\u003e\n\u003cli\u003eIntegrates with Honeywell Safety Manager SC and Experion HS platforms\u003c\/li\u003e\n\u003cli\u003eSupports redundant configurations for high availability applications\u003c\/li\u003e\n\u003cli\u003eIncludes comprehensive diagnostics for channel fault detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Configuration Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount on DIN rail in properly rated industrial enclosure\u003c\/li\u003e\n\u003cli\u003eEnsure proper isolation and spacing for high-voltage wiring\u003c\/li\u003e\n\u003cli\u003eConnect 110V DC power supply to load side of outputs\u003c\/li\u003e\n\u003cli\u003eUse Safety Builder software for configuration and testing\u003c\/li\u003e\n\u003cli\u003eImplement proper grounding according to IEC standards\u003c\/li\u003e\n\u003cli\u003eDo not exceed 0.32A per channel continuous current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eHoneywell FS-SDO-04110\u003c\/strong\u003e is packaged in ESD-protective materials\u003c\/li\u003e\n\u003cli\u003eIncludes module, documentation, and terminal blocks\u003c\/li\u003e\n\u003cli\u003eShipped via \u003cstrong\u003eFedEx, DHL, or UPS\u003c\/strong\u003e with tracking\u003c\/li\u003e\n\u003cli\u003eInternational shipping available with customs documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat safety level does it support?\u003c\/strong\u003e Certified for \u003cstrong\u003eSIL 3 \/ PLe\u003c\/strong\u003e applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the output voltage?\u003c\/strong\u003e \u003cstrong\u003e110 V DC\u003c\/strong\u003e output voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many output channels?\u003c\/strong\u003e \u003cstrong\u003e4 independent channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the current rating?\u003c\/strong\u003e \u003cstrong\u003e0.32 A per channel\u003c\/strong\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat diagnostics are included?\u003c\/strong\u003e Short-circuit, overload, and wire-break diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical documentation or to order the \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eHoneywell FS-SDO-04110\u003c\/span\u003e\u003c\/strong\u003e, contact us.\u003cbr\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner NexAuto Technology Limited :\u003cbr\u003e\u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e© 2025 AutoNex Controls Limited. All rights reserved.\u003cbr\u003eOriginal Source: AutoNex Controls Limited :\u003cbr\u003e\u003ca href=\"https:\/\/www.autonexcontrol.com\/\"\u003ehttps:\/\/www.autonexcontrol.com\/\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45581186760865,"sku":"FS-SDO-04110","price":289.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/FS-SDO-04110.jpg?v=1766720346","url":"https:\/\/www.autonexcontrol.com\/vi\/products\/honeywell-fs-sdo-04110-110v-dc-safety-output","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}