{"product_id":"honeywell-digital-input-module-soe-card-cc-pdis01","title":"Honeywell Digital Input Module | SOE Card CC-PDIS01","description":"\u003ch2\u003eHoneywell CC-PDIS01 Digital Input Sequence of Events Module\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003eCC-PDIS01\u003c\/strong\u003e Digital Input Sequence of Events module processes 24VDC discrete signals with high precision. It provides accurate time tagging for events with \u003cspan style=\"color: #ff0000;\"\u003e1 millisecond resolution\u003c\/span\u003e for reliable system monitoring and fault analysis in industrial applications.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Operating Modes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree operational modes: Normal, Sequence of Events, and Low Latency\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e1ms resolution\u003c\/span\u003e for precise event sequencing in SOE mode\u003c\/li\u003e\n\u003cli\u003e20ms process variable scan in Normal mode with open wire detection\u003c\/li\u003e\n\u003cli\u003e5ms process variable scan in Low Latency mode for critical inputs\u003c\/li\u003e\n\u003cli\u003eComprehensive internal diagnostics ensure data integrity\u003c\/li\u003e\n\u003cli\u003eOn-board excitation power eliminates marshalling power requirements\u003c\/li\u003e\n\u003cli\u003eNon-incendive field power for hazardous area applications\u003c\/li\u003e\n\u003cli\u003eConfigurable direct\/reverse input indication\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #ff0000;\"\u003eGalvanic isolation\u003c\/span\u003e protects against ground loops and noise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eCC-PDIS01\u003c\/strong\u003e Digital Input Sequence of Events\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible IOTA Models:\u003c\/strong\u003e \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eCC-TDIL01\u003c\/strong\u003e, \u003cstrong\u003eCC-TDIL11\u003c\/strong\u003e, \u003cstrong\u003eCC-GDIL11\u003c\/strong\u003e, \u003cstrong\u003eCC-GDIL21\u003c\/strong\u003e, \u003cstrong\u003eCC-GDIL01\u003c\/strong\u003e, \u003cstrong\u003eCC-SDXX01\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 32 discrete channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV Scan Time:\u003c\/strong\u003e Normal = 20ms; Low Latency = 5ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSOE Resolution:\u003c\/strong\u003e \u003cspan style=\"color: #ff0000;\"\u003e1 millisecond\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e 1500 VAC RMS or ±1500 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Power Voltage Range:\u003c\/strong\u003e 18 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON Sense Voltage\/Current:\u003c\/strong\u003e 13 VDC min \/ 3 mA min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF Sense Voltage\/Current:\u003c\/strong\u003e 5 VDC max \/ 1.2 mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 4.2 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Delay:\u003c\/strong\u003e 5 ms ± 20% across input filter and isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Wiring and Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOpen wire detection capability in Normal operation mode\u003c\/li\u003e\n\u003cli\u003eAutomatic invalid status reporting for diagnosed faulty channels\u003c\/li\u003e\n\u003cli\u003ePrevents incorrect control actions with invalid status signals\u003c\/li\u003e\n\u003cli\u003eGuaranteed ON condition: 300 Ω max field resistance at 15 VDC\u003c\/li\u003e\n\u003cli\u003eGuaranteed OFF condition: 30 kΩ min field resistance at 30 VDC\u003c\/li\u003e\n\u003cli\u003eSeries C architecture enhances diagnostic capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging and Shipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes one Honeywell \u003cstrong\u003eCC-PDIS01\u003c\/strong\u003e module unit\u003c\/li\u003e\n\u003cli\u003eAll necessary hardware included for immediate installation\u003c\/li\u003e\n\u003cli\u003eInternational shipping via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003cli\u003eSecure packaging ensures product protection during transit\u003c\/li\u003e\n\u003cli\u003eFast order processing for quick delivery turnaround\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the main advantage of the CC-PDIS01 module? Its 1ms SOE resolution for accurate event time-stamping\u003c\/li\u003e\n\u003cli\u003eHow many input channels does this module support? 32 discrete input channels\u003c\/li\u003e\n\u003cli\u003eDoes it support redundant configurations? Yes, with IOTA models like CC-TDIL11\u003c\/li\u003e\n\u003cli\u003eWhat is the isolation rating? 1500 VAC RMS galvanic isolation\u003c\/li\u003e\n\u003cli\u003eCan it detect wiring problems? Yes, with open wire detection in Normal mode\u003c\/li\u003e\n\u003cli\u003eWhat power supply does it require? 18 to 30 VDC field power voltage\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45280587874465,"sku":"CC-PDIS01","price":266.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/CC-PDIS01.jpg?v=1761623727","url":"https:\/\/www.autonexcontrol.com\/vi\/products\/honeywell-digital-input-module-soe-card-cc-pdis01","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}