{"product_id":"ge-fanuc-ic660bcm501-battery-charger-genius-i-o","title":"GE Fanuc IC660BCM501 Battery Charger – Genius I\/O","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC660BCM501 Battery Charger – Genius I\/O Handheld Monitor Power Solution\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Genius I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC660BCM501\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternate product codes:\u003c\/strong\u003e CIMIC660BCM501, GEFIC660BCM501, 1C660BCM501\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Battery charger for handheld monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e \u003cstrong\u003eIC660HHM501\u003c\/strong\u003e handheld monitor only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage:\u003c\/strong\u003e 115 V AC or 230 V AC, switch selectable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum charging time:\u003c\/strong\u003e 15 minutes before first use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage selection:\u003c\/strong\u003e Manual switch at base of charger\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation during charging:\u003c\/strong\u003e Supported, monitor runs while charging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical and Interface Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003eLCD display:\u003c\/strong\u003e\u003c\/span\u003e 4 lines, 16 characters each, clear alphanumeric readout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeypad:\u003c\/strong\u003e 20-key sealed membrane, resistant to industrial contaminants\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeypad layout:\u003c\/strong\u003e Function keys F1-F4, operation keys, decimal keys\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay languages:\u003c\/strong\u003e English, French, Italian, German selectable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyswitch:\u003c\/strong\u003e Configure (CFG) and Monitor (MON) positions with key removal security\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003eBattery must remain installed:\u003c\/strong\u003e\u003c\/span\u003e Unit will not operate without battery pack, even on AC power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage selector switch:\u003c\/strong\u003e Must match incoming AC supply before connecting power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial charge requirement:\u003c\/strong\u003e 15 minutes minimum for new or fully discharged batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency operation:\u003c\/strong\u003e Charge 15 minutes before power-up if battery depleted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery reset procedure:\u003c\/strong\u003e Remove battery pack for 15-20 seconds, then reinstall\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous AC operation:\u003c\/strong\u003e Causes battery deterioration after approximately 2 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegraded battery:\u003c\/strong\u003e May not hold charge for independent use, but AC operation remains functional\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the \u003cstrong\u003eIC660BCM501\u003c\/strong\u003e used for?\u003c\/strong\u003e\u003cbr\u003eIt charges the internal battery pack for the GE Fanuc IC660HHM501 handheld monitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I operate the handheld monitor without the battery installed?\u003c\/strong\u003e\u003cbr\u003eNo, the battery must always remain installed even when using AC power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat input voltages does the \u003cstrong\u003eIC660BCM501\u003c\/strong\u003e support?\u003c\/strong\u003e\u003cbr\u003eIt supports 115 V AC and 230 V AC via manual voltage selector switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow long does the battery need to charge initially?\u003c\/strong\u003e\u003cbr\u003eA minimum of 15 minutes is required for new or fully discharged batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use the monitor while it is charging?\u003c\/strong\u003e\u003cbr\u003eYes, the handheld monitor operates normally while connected to the \u003cstrong\u003eIC660BCM501\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat happens if I run the monitor on AC power continuously?\u003c\/strong\u003e\u003cbr\u003eAfter about 2 years, the internal battery may lose capacity for independent operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I reset the battery system?\u003c\/strong\u003e\u003cbr\u003eRemove the battery pack for 15 to 20 seconds, then reinstall it securely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat languages does the display support?\u003c\/strong\u003e\u003cbr\u003eEnglish, French, Italian, and German are available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many keys come with the \u003cstrong\u003eIC660BCM501\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eEach new unit ships with two identical keys for the keyswitch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this product new and original?\u003c\/strong\u003e\u003cbr\u003eYes, every \u003cstrong\u003eIC660BCM501\u003c\/strong\u003e is brand new and factory-sealed GE Fanuc product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003cbr\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003eWhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45710893121697,"sku":"IC660BCM501","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC660BCM501-1.jpg?v=1770882515","url":"https:\/\/www.autonexcontrol.com\/vi\/products\/ge-fanuc-ic660bcm501-battery-charger-genius-i-o","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}