{"product_id":"ge-fanuc-ic200alg320-output-module","title":"GE Fanuc IC200ALG320 Output Module","description":"\u003ch2\u003eGE Fanuc VersaMax IC200ALG320 Analog Current Output Module\u003c\/h2\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: GE Fanuc\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003eIC200ALG320\u003c\/strong\u003e | Series: VersaMax\u003c\/li\u003e\n\u003cli\u003eProduct Type: 4-Point Analog Current Output Module\u003c\/li\u003e\n\u003cli\u003eOutput Channels: 4 single-ended current-sourcing outputs\u003c\/li\u003e\n\u003cli\u003eCurrent Range: \u003cspan style=\"color: #ff6600;\"\u003e4-20 mA\u003c\/span\u003e standard output signal\u003c\/li\u003e\n\u003cli\u003eResolution: 12-bit conversion with 4 µA precision\u003c\/li\u003e\n\u003cli\u003eUpdate Rate: 0.3 milliseconds maximum speed\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±0.3% typical, ±1% maximum full scale\u003c\/li\u003e\n\u003cli\u003eExternal Power: 18-30VDC or 9.6-15VDC required\u003c\/li\u003e\n\u003cli\u003eBackplane Power: 5VDC at 50mA maximum\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 240mA maximum from field supply\u003c\/li\u003e\n\u003cli\u003eIsolation: 250VAC continuous, 1500VAC for 1 minute\u003c\/li\u003e\n\u003cli\u003eLED Indicators: FLD PWR and OK status lights\u003c\/li\u003e\n\u003cli\u003eDefault Output: Hold last state or 4mA on fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Output Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour independent current-sourcing output channels\u003c\/li\u003e\n\u003cli\u003eHigh-speed 0.3ms update rate for real-time control\u003c\/li\u003e\n\u003cli\u003e12-bit resolution ensures precise current regulation\u003c\/li\u003e\n\u003cli\u003eConfigurable fault states: hold last or default to 4mA\u003c\/li\u003e\n\u003cli\u003eCompatible with modulating valves and VFDs\u003c\/li\u003e\n\u003cli\u003eIdeal for signal retransmission and cascade control\u003c\/li\u003e\n\u003cli\u003eSupports panel meters and data logging systems\u003c\/li\u003e\n\u003cli\u003eRobust design for industrial environment operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Power Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExternal power supply required: 18-30VDC or 9.6-15VDC\u003c\/li\u003e\n\u003cli\u003eBackplane powered for control logic operation\u003c\/li\u003e\n\u003cli\u003eSingle-ended wiring configuration simplifies installation\u003c\/li\u003e\n\u003cli\u003eSingle group output organization for easy management\u003c\/li\u003e\n\u003cli\u003eCompact design fits standard VersaMax enclosures\u003c\/li\u003e\n\u003cli\u003eEasy integration into distributed I\/O networks\u003c\/li\u003e\n\u003cli\u003eSuitable for remote location installation\u003c\/li\u003e\n\u003cli\u003eReduces long signal runs in large control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics \u0026amp; Status Monitoring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFLD PWR LED indicates field power presence\u003c\/li\u003e\n\u003cli\u003eOK LED confirms backplane power and configuration\u003c\/li\u003e\n\u003cli\u003eLoss of user-side power detection and reporting\u003c\/li\u003e\n\u003cli\u003eConfigurable output response during CPU stoppage\u003c\/li\u003e\n\u003cli\u003eComprehensive fault detection and status monitoring\u003c\/li\u003e\n\u003cli\u003eIsolation protection for enhanced safety\u003c\/li\u003e\n\u003cli\u003eIndividual channel status monitoring capability\u003c\/li\u003e\n\u003cli\u003eError reporting to main control system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat current output range does the IC200ALG320 provide?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe module delivers 4-20mA current signals across all four output channels with high precision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHow many output channels are available?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIC200ALG320\u003c\/strong\u003e provides four single-ended analog current output channels in one group.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat power supply does this module require?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIt needs an external 18-30VDC or 9.6-15VDC power supply for output operation, plus backplane power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is the update rate for output signals?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIt features a very fast 0.3 millisecond update rate for responsive control applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat happens during a fault condition?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOutputs can be configured to hold last state or default to 4mA during CPU stop or module faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is your shipping timeframe?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWe process orders within 5 business days and ship via reliable carriers including DHL, FedEx, and UPS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDo you offer return privileges?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYes, we provide a 30-day return policy for products in original condition with complete packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e \u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139254640801,"sku":"IC200ALG320","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC200ALG320-3.jpg?v=1763542657","url":"https:\/\/www.autonexcontrol.com\/vi\/products\/ge-fanuc-ic200alg320-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}