{"product_id":"allen-bradley-1756-oc8-dc-output-module","title":"Allen-Bradley 1756-OC8 DC Output Module","description":"\u003ch2\u003e\u003cstrong\u003eAllen-Bradley 1756-OC8 ControlLogix Digital Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Manufacturer:\u003c\/strong\u003e Allen Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ControlLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e1756-OC8\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e DC Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #e06c75;\"\u003e48 Volts DC Source\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e \u003cspan style=\"color: #e06c75;\"\u003e30-60 Volts DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Points:\u003c\/strong\u003e 8 Points (4 points per group)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current per Point:\u003c\/strong\u003e \u003cstrong\u003e2 Amps\u003c\/strong\u003e at 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current per Module:\u003c\/strong\u003e \u003cstrong\u003e8 Amps\u003c\/strong\u003e at 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Performance Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current:\u003c\/strong\u003e 4 Amps for 10 ms per point (repeatable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Drop:\u003c\/strong\u003e 2 VDC maximum at 2A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Leakage:\u003c\/strong\u003e 1 mA maximum per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Delay:\u003c\/strong\u003e 1 ms (Off to On), 2 ms (On to Off)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Load Current:\u003c\/strong\u003e 2 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power:\u003c\/strong\u003e 0.89 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 165 mA @ 5.1V, 2 mA @ 24V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Terminal Block:\u003c\/strong\u003e 20-pin \u003cstrong\u003e1756-TBNH\u003c\/strong\u003e or \u003cstrong\u003e1756-TBSH\u003c\/strong\u003e (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install in any slot of a grounded ControlLogix chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Note:\u003c\/strong\u003e Module is not fused; use a fused IFM (Input\/Output Module) for output protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Fuse:\u003c\/strong\u003e 5x20mm 4A quick-acting fuse (e.g., SOC MQ2-4A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 50 Volts continuous.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational \u0026amp; System Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Formats:\u003c\/strong\u003e Rack Optimization, Scheduled Output Data, Listen-Only modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault State Configuration:\u003c\/strong\u003e Set per point to \u003cstrong\u003eOn, Off, or Hold Last State\u003c\/strong\u003e (default is Off).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 4.9 Watts maximum at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e 16.71 BTU\/hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Rated for up to 60°C (140°F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What voltage does the 1756-OC8 module require?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The \u003cstrong\u003e1756-OC8\u003c\/strong\u003e operates on a \u003cstrong\u003e30-60V DC\u003c\/strong\u003e supply, with a nominal rating of 48V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much current can I draw from a single output?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Each output point supports a maximum continuous current of \u003cstrong\u003e2 Amps\u003c\/strong\u003e at 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What terminal block do I need for this module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e You need a 20-pin removable terminal block, either the \u003cstrong\u003e1756-TBNH\u003c\/strong\u003e or the \u003cstrong\u003e1756-TBSH\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is fuse protection included with the module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No, the module is not internally fused. We recommend using an external fused IFM for protection. A 4A quick-acting fuse is suggested.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have the 1756-OC8 in stock ready to ship?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, we stock the \u003cstrong\u003e1756-OC8\u003c\/strong\u003e and typically ship orders within 5 business days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor more information or to purchase the \u003cstrong\u003e1756-OC8\u003c\/strong\u003e module, contact our sales team today.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information Inquiries:\u003c\/strong\u003e \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e , \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner \u003cstrong\u003eNexAuto Technology Limited\u003c\/strong\u003e : \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45503786516641,"sku":"1756-OC8","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/1756-OC8.jpg?v=1764922808","url":"https:\/\/www.autonexcontrol.com\/vi\/products\/allen-bradley-1756-oc8-dc-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}