{"product_id":"900h02-0102-honeywell-low-side-1a-dc-output-module","title":"900H02-0102 Honeywell Low-Side 1A DC Output Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell 900H02-0102 DC Digital Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #d35400;\"\u003e900H02-0102\u003c\/strong\u003e is a 16-channel DC sinking output module for the \u003cstrong\u003eHoneywell HC900\u003c\/strong\u003e controller. It provides intelligent switching for DC loads with built-in electronic protection and diagnostic status indicators.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong style=\"color: #d35400;\"\u003e900H02-0102\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Output (DO) Module, DC Voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs per Module:\u003c\/strong\u003e 16 Channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Current Sinking, Low-Side Switch (Intelligent Power Switch - IPS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e 6.5 to 32 VDC (5.0 to 6.5 VDC @ \u0026lt;0.5A per channel)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Voltage Rating:\u003c\/strong\u003e 34 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e 2 Groups of 8 Outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON Voltage Drop:\u003c\/strong\u003e 0.3 VDC @ 1 A Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Current:\u003c\/strong\u003e 1 A per Point, 8 A Maximum per Module (Resistive Load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Incandescent Lamp Load:\u003c\/strong\u003e 0.5 A per Point (5 mH max inductance)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Leakage Current:\u003c\/strong\u003e 0.15 mA @ 32 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Inrush Current:\u003c\/strong\u003e 4 A for 10 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Load:\u003c\/strong\u003e 0.0 mA (No Minimum Required)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF to ON Response Time:\u003c\/strong\u003e 6 ms (excluding controller scan \u0026amp; backplane transmission)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON to OFF Response Time:\u003c\/strong\u003e 6 ms (excluding controller scan \u0026amp; backplane transmission)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Protection:\u003c\/strong\u003e Electronic High Current \u0026amp; High Temperature Limiting; Reset requires cycling field power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Loading (from Backplane):\u003c\/strong\u003e 5V; 340 mA, 24V; 0 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\n\u003cul style=\"margin-top: 5px; padding-left: 20px;\"\u003e\n\u003cli\u003eGreen LED per Channel (Output ON)\u003c\/li\u003e\n\u003cli\u003eGreen Blinking Module LED (Active Scan)\u003c\/li\u003e\n\u003cli\u003eAmber Blinking Module LED (Channels Forced)\u003c\/li\u003e\n\u003cli\u003eRed Module LED (Fault\/Diagnostic)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C (Standard HC900 Range)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModule Features \u0026amp; Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-side sinking outputs are ideal for interfacing with PLCs and devices that expect a common positive voltage.\u003c\/li\u003e\n\u003cli\u003eIntelligent Power Switch (IPS) technology provides efficient switching with low voltage drop.\u003c\/li\u003e\n\u003cli\u003eElectronic overload protection guards against short circuits and overtemperature conditions.\u003c\/li\u003e\n\u003cli\u003eClear multi-color module status LEDs indicate operational mode: normal scan, forced outputs, or faults.\u003c\/li\u003e\n\u003cli\u003eProtection reset requires cycling the external field power, preventing automatic restart after a fault.\u003c\/li\u003e\n\u003cli\u003eNo external fuses required; protection is integrated electronically.\u003c\/li\u003e\n\u003cli\u003eGrouped isolation (2 groups of 8) allows connection to two different DC power sources.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in a compatible Honeywell HC900 rack. Provide external DC power (6.5-32V) for the field loads.\u003c\/li\u003e\n\u003cli\u003eConnect the external DC+ supply to the common positive of the field loads.\u003c\/li\u003e\n\u003cli\u003eConnect the load between the output terminal (sinking side) and the DC- (common negative).\u003c\/li\u003e\n\u003cli\u003eWire outputs in groups of 8, each group to its own +V and COM terminals on the module.\u003c\/li\u003e\n\u003cli\u003eDo not exceed 1A continuous current per output or 8A total per module.\u003c\/li\u003e\n\u003cli\u003eFor inductive loads, use external flyback diodes across the load to protect the output switch.\u003c\/li\u003e\n\u003cli\u003eIf an overload trips, disconnect the field power to reset the module's protection circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDriving indicator lamps, LED arrays, and small DC relays.\u003c\/li\u003e\n\u003cli\u003eControlling solenoid valves and low-power DC actuators.\u003c\/li\u003e\n\u003cli\u003eInterfacing with other control systems requiring a sinking input signal.\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose DC output control in machinery and automated systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor detailed wiring diagrams or to order the \u003cstrong\u003eHoneywell 900H02-0102\u003c\/strong\u003e, contact our technical sales team.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@nex-auto.com\"\u003e\u003cstrong\u003esales@nex-auto.com\u003c\/strong\u003e\u003c\/a\u003e or WhatsApp \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e\u003cstrong\u003e+86 153 9242 9628\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003e\u003cstrong\u003eNexAuto Technology Limited\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e© 2026 \u003ca href=\"https:\/\/www.autonexcontrol.com\/\"\u003e\u003cstrong\u003eAutoNex Controls Limited\u003c\/strong\u003e\u003c\/a\u003e. All rights reserved.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45621721596065,"sku":"900H02-0102","price":311.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/900H02-0102.jpg?v=1767600750","url":"https:\/\/www.autonexcontrol.com\/vi\/products\/900h02-0102-honeywell-low-side-1a-dc-output-module","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}