{"product_id":"vibration-transmitter-bently-nevada-990-08-50-01-00","title":"Vibration Transmitter Bently Nevada 990-08-50-01-00","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 990-08-50-01-00 Vibration Transmitter Product\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Bently Nevada \u003cstrong style=\"color: #2e86c1;\"\u003e990-08-50-01-00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-Scale Range:\u003c\/strong\u003e 0 to 8 mils peak-to-peak \u003cstrong style=\"color: #2e86c1;\"\u003e(0 to 200 μm pp)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e 5 Hz to 6,000 Hz \u003cstrong style=\"color: #2e86c1;\"\u003e(+0, -3 dB)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Cable Length:\u003c\/strong\u003e 5.0 meters \u003cstrong style=\"color: #2e86c1;\"\u003e(16.4 feet)\u003c\/strong\u003e standard configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Accuracy:\u003c\/strong\u003e Within \u003cstrong style=\"color: #2e86c1;\"\u003e±1.5%\u003c\/strong\u003e of full-scale range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Requires \u003cstrong style=\"color: #2e86c1;\"\u003e+12 to +35 Vdc\u003c\/strong\u003e input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Output:\u003c\/strong\u003e 4 to 20 mA dc two-wire configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e 23 mA typical for circuit protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Loop Resistance:\u003c\/strong\u003e 1,000 Ω at 35 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e 35 mm DIN rail clips for easy installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Operation Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e Accepts one \u003cstrong style=\"color: #2e86c1;\"\u003e3300 NSv\u003c\/strong\u003e Proximity Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Setting:\u003c\/strong\u003e Install between \u003cstrong style=\"color: #2e86c1;\"\u003e0.5-1.75 mm (20-55 mils)\u003c\/strong\u003e from target\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Target Size:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86c1;\"\u003e9.5 mm (0.375 inches)\u003c\/strong\u003e diameter minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Adjustments:\u003c\/strong\u003e Non-interacting external zero and span controls\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Response:\u003c\/strong\u003e Output drops below 3.6 mA within 100 µs during NOT OK condition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecovery Time:\u003c\/strong\u003e Normal output restores within 2-3 seconds after fault clearance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Distance:\u003c\/strong\u003e Maximum 3 meters (10 feet) from probe to BNC connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Rating:\u003c\/strong\u003e Suitable for Non-Hazardous and Zone 2\/Div 2 areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat vibration range does this model measure?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003e990-08-50-01-00\u003c\/strong\u003e covers 0-8 mils peak-to-peak (0-200 micrometers).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I mount this transmitter in my panel?\u003c\/strong\u003e\u003cbr\u003eIt includes 35 mm DIN rail clips for quick and secure industrial panel mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat happens during a sensor fault condition?\u003c\/strong\u003e\u003cbr\u003eThe output immediately drops below 3.6 mA to clearly indicate a NOT OK status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use longer extension cables than specified?\u003c\/strong\u003e\u003cbr\u003eWe recommend staying within the 5-meter system length for optimal performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this unit suitable for hazardous locations?\u003c\/strong\u003e\u003cbr\u003eYes, it carries approvals for Zone 2 and Division 2 hazardous area installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat power supply voltage works best?\u003c\/strong\u003e\u003cbr\u003eA 28 Vdc supply is recommended, but any voltage between +12 to +35 Vdc will work.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor complete details, \u003ca rel=\"noopener\" href=\"https:\/\/ctrlnexus-auto.com\/wp-content\/uploads\/2025\/06\/990-Vibration-Transmitter-Datasheet.pdf\" target=\"_blank\"\u003edownload the full 990 datasheet here\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information for Technical Inquiries:\u003c\/strong\u003e\u003cbr\u003eEmail: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eAuthorized Partner: \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45511613218977,"sku":"990-08-50-01-00","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/990-08-50-01-00.jpg?v=1765173057","url":"https:\/\/www.autonexcontrol.com\/uk\/products\/vibration-transmitter-bently-nevada-990-08-50-01-00","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}