{"product_id":"ge-fanuc-mixed-i-o-module-ic200mdd850","title":"GE Fanuc Mixed I\/O Module IC200MDD850","description":"\u003ch2\u003eGE Fanuc IC200MDD850: Advanced Relay Control Solution\u003c\/h2\u003e\n\u003ch3\u003eProduct Profile\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e:GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Platform\u003c\/strong\u003e: Versamax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Designation\u003c\/strong\u003e: \u003cstrong\u003eIC200MDD850\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Category\u003c\/strong\u003e: Mixed Output Relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e: \u003cspan style=\"color: #c0392b;\"\u003e8 Outputs\u003c\/span\u003e + \u003cspan style=\"color: #2980b9;\"\u003e4 Inputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput Channel Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity\u003c\/strong\u003e: \u003cspan style=\"color: #2980b9;\"\u003e4 Isolated Discrete Inputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Types\u003c\/strong\u003e: Positive Logic \/ Sourcing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Processing\u003c\/strong\u003e: NIU\/CPU Dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indication\u003c\/strong\u003e: Individual LED Indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutput Channel Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Count\u003c\/strong\u003e: \u003cspan style=\"color: #c0392b;\"\u003e8 Relay Outputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity\u003c\/strong\u003e: \u003cspan style=\"color: #c0392b;\"\u003e2 A per Point\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Design\u003c\/strong\u003e: Fully Isolated Outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Power Source\u003c\/strong\u003e: External Supply Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Parameters\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Ranges\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn-State: \u003cspan style=\"color: #f39c12;\"\u003e155-264 V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOff-State: \u003cspan style=\"color: #f39c12;\"\u003e0-40 V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBackplane Voltage: 5 V DC\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: \u003cspan style=\"color: #27ae60;\"\u003eMax 275 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eLoad Power: External Source Needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSuitable Applications\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Control Systems\u003c\/li\u003e\n\u003cli\u003eMachine Automation\u003c\/li\u003e\n\u003cli\u003eProcess Control\u003c\/li\u003e\n\u003cli\u003eEquipment Sequencing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImplementation Notes\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExternal Load Power Required\u003c\/li\u003e\n\u003cli\u003eNIU\/CPU Mandatory for Operation\u003c\/li\u003e\n\u003cli\u003eVoltage Range Compliance Essential\u003c\/li\u003e\n\u003cli\u003eRegular Status Monitoring Recommended\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Summary\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Channels\u003c\/strong\u003e: 12 (8 Out + 4 In)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type\u003c\/strong\u003e: Isolated Relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e: Positive\/Sourcing Logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Operation\u003c\/strong\u003e: 155-264V AC On-State\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Draw\u003c\/strong\u003e: 275mA @ 5V Backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus System\u003c\/strong\u003e: Comprehensive LED Indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat processing unit is required?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eIC200MDD850\u003c\/strong\u003e requires a Versamax NIU or CPU for intelligent processing and logic control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many input channels are provided?\u003c\/strong\u003e\u003cbr\u003eThe module includes \u003cspan style=\"color: #2980b9;\"\u003e4 isolated discrete inputs\u003c\/span\u003e supporting positive logic or sourcing types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum output current?\u003c\/strong\u003e\u003cbr\u003eEach of the \u003cspan style=\"color: #c0392b;\"\u003e8 relay outputs\u003c\/span\u003e can handle up to \u003cspan style=\"color: #c0392b;\"\u003e2 A\u003c\/span\u003e with proper external power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAre the status indicators load-dependent?\u003c\/strong\u003e\u003cbr\u003eNo, the LED indicators show input\/output status independently of load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat voltage range does it support?\u003c\/strong\u003e\u003cbr\u003eThe module operates with \u003cspan style=\"color: #f39c12;\"\u003e155-264 V AC\u003c\/span\u003e on-state and \u003cspan style=\"color: #f39c12;\"\u003e0-40 V AC\u003c\/span\u003e off-state voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat pre-installation check is recommended?\u003c\/strong\u003e\u003cbr\u003eAlways inspect the module for any shipping damage before installation and commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor technical support and ordering information:\u003c\/em\u003e \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139259719841,"sku":"IC200MDD850","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC200MDD850.jpg?v=1763621871","url":"https:\/\/www.autonexcontrol.com\/uk\/products\/ge-fanuc-mixed-i-o-module-ic200mdd850","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}