{"product_id":"ge-fanuc-i-o-module-ic200mdd848","title":"GE Fanuc | I\/O Module IC200MDD848","description":"\u003ch2\u003eHigh-Capacity Control: GE Fanuc IC200MDD848 Mixed I\/O Module\u003c\/h2\u003e\n\u003ch3\u003eModule Configuration \u0026amp; Capacity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal I\/O Points\u003c\/strong\u003e: \u003cspan style=\"color: #c0392b;\"\u003e16 points\u003c\/span\u003e for comprehensive control needs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels\u003c\/strong\u003e: \u003cspan style=\"color: #2980b9;\"\u003e8 positive logic\/sourcing-type\u003c\/span\u003e inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels\u003c\/strong\u003e: \u003cspan style=\"color: #27ae60;\"\u003e8 relay outputs\u003c\/span\u003e with high-current capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range\u003c\/strong\u003e: \u003cspan style=\"color: #c0392b;\"\u003e10 mA minimum\u003c\/span\u003e to \u003cspan style=\"color: #2980b9;\"\u003e5 A maximum\u003c\/span\u003e load current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: \u003cspan style=\"color: #27ae60;\"\u003e5 V\u003c\/span\u003e backplane operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: Only \u003cspan style=\"color: #f39c12;\"\u003e125 mA\u003c\/span\u003e from backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput Performance Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Type\u003c\/strong\u003e: Positive logic for standard industrial compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Design\u003c\/strong\u003e: Sourcing-type configuration for flexible wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Reliability\u003c\/strong\u003e: Consistent performance across all input channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Standard\u003c\/strong\u003e: Matches common sensor and switch types\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Integration\u003c\/strong\u003e: Simple connection to various field devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Application\u003c\/strong\u003e: Suitable for multiple control scenarios\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutput Power \u0026amp; Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Outputs\u003c\/strong\u003e: \u003cspan style=\"color: #2980b9;\"\u003e5 A maximum\u003c\/span\u003e per output channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Current Operation\u003c\/strong\u003e: Handles down to \u003cspan style=\"color: #c0392b;\"\u003e10 mA minimum\u003c\/span\u003e loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Protection\u003c\/strong\u003e: MOVs and snubbers for surge suppression\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Reliability\u003c\/strong\u003e: Robust output contacts for long service life\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Versatility\u003c\/strong\u003e: Accommodates various industrial load types\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Features\u003c\/strong\u003e: Built-in protection for connected equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Efficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Design\u003c\/strong\u003e: Only 125 mA backplane consumption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable Operation\u003c\/strong\u003e: 5 V backplane voltage for reliable performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Efficient\u003c\/strong\u003e: Minimal power requirements for operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Management\u003c\/strong\u003e: Efficient design reduces thermal output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Works with standard Versamax power supplies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCost Effective\u003c\/strong\u003e: Low operating costs over product lifetime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection \u0026amp; Reliability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Protection\u003c\/strong\u003e: MOVs suppress voltage transients\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc Suppression\u003c\/strong\u003e: Snubbers protect relay contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLongevity\u003c\/strong\u003e: Enhanced protection extends module lifespan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Reduction\u003c\/strong\u003e: Fewer replacements and repairs needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Protection\u003c\/strong\u003e: Safeguards connected equipment and wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Operation\u003c\/strong\u003e: Consistent performance in harsh conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Saving\u003c\/strong\u003e: Compact 16-point design optimizes panel space\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Mounting\u003c\/strong\u003e: Simple installation in Versamax racks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Efficiency\u003c\/strong\u003e: Organized connection layout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick Commissioning\u003c\/strong\u003e: Fast setup and configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: Seamless Versamax platform compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Friendly\u003c\/strong\u003e: Easy access for service and troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum output current capacity?\u003c\/strong\u003e\u003cbr\u003eThe module handles up to \u003cspan style=\"color: #2980b9;\"\u003e5 A\u003c\/span\u003e per output channel for heavy loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat type of input configuration does it use?\u003c\/strong\u003e\u003cbr\u003eIt features \u003cspan style=\"color: #2980b9;\"\u003e8 positive logic\/sourcing-type\u003c\/span\u003e input channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat protection features are included?\u003c\/strong\u003e\u003cbr\u003eThe module includes \u003cstrong\u003eMOVs and snubbers\u003c\/strong\u003e for surge and arc suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow much power does it consume?\u003c\/strong\u003e\u003cbr\u003eIt draws only \u003cspan style=\"color: #f39c12;\"\u003e125 mA\u003c\/span\u003e from the \u003cspan style=\"color: #27ae60;\"\u003e5 V\u003c\/span\u003e backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the total I\/O point count?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eIC200MDD848\u003c\/strong\u003e provides \u003cspan style=\"color: #c0392b;\"\u003e16 total I\/O points\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this module available from stock?\u003c\/strong\u003e\u003cbr\u003eWe maintain \u003cstrong\u003egenuine GE Fanuc\u003c\/strong\u003e inventory for quick shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFor complete technical details and pricing information, contact us at\u003c\/em\u003e \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139249791137,"sku":"IC200MDD848","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC200MDD848.jpg?v=1763620845","url":"https:\/\/www.autonexcontrol.com\/uk\/products\/ge-fanuc-i-o-module-ic200mdd848","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}