{"product_id":"communication-module-ge-fanuc-ic695cmm004","title":"Communication Module GE Fanuc IC695CMM004","description":"\u003ch2\u003eGE Fanuc IC695CMM004 RX3i 4-Port Serial Communication Module\u003c\/h2\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003eGE Fanuc\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIC695CMM004\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Configuration:\u003c\/strong\u003e Four independent RJ-45 serial ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e \u003cspan style=\"color: #d9534f;\"\u003e0.7 A at 3.3 VDC\u003c\/span\u003e and \u003cspan style=\"color: #d9534f;\"\u003e0.15 A at 5 VDC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e MODBUS, DNP3, CCM, and Serial I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Modes:\u003c\/strong\u003e RS-232, RS-422, RS-485 selectable per port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rate Range:\u003c\/strong\u003e 1200 to 115200 baud selectable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Rating:\u003c\/strong\u003e \u003cspan style=\"color: #d9534f;\"\u003e500 VDC continuous\u003c\/span\u003e port-to-port isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Modules:\u003c\/strong\u003e Up to \u003cspan style=\"color: #007bff;\"\u003e6 modules\u003c\/span\u003e per rack system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Control:\u003c\/strong\u003e Default full-duplex with half-duplex configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60°C industrial range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE and UL\/CUL 508 with ATEX compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #007bff;\"\u003eFour independent serial ports\u003c\/span\u003e provide flexible connectivity options\u003c\/li\u003e\n\u003cli\u003eMultiple protocol support including MODBUS and DNP3 industry standards\u003c\/li\u003e\n\u003cli\u003eSelectable RS-232, RS-422, and RS-485 modes for each port\u003c\/li\u003e\n\u003cli\u003eWide baud rate selection from 1200 to 115200 for various applications\u003c\/li\u003e\n\u003cli\u003eConfigurable flow control with full-duplex and half-duplex operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Characteristics and Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d9534f;\"\u003eRobust 500 VDC continuous isolation\u003c\/span\u003e between all communication ports\u003c\/li\u003e\n\u003cli\u003eHigh port-to-backplane isolation for enhanced system protection\u003c\/li\u003e\n\u003cli\u003eEfficient power consumption for multi-module installations\u003c\/li\u003e\n\u003cli\u003eStandard RJ-45 connectors for reliable cable connections\u003c\/li\u003e\n\u003cli\u003eConfigurable serial parameters for precise communication setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eHow many serial ports does the IC695CMM004 provide?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIC695CMM004\u003c\/strong\u003e offers \u003cspan style=\"color: #007bff;\"\u003efour independent serial ports\u003c\/span\u003e. Each port features standard RJ-45 connectors for easy cable connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat communication protocols does this module support?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThis module supports MODBUS, DNP3, CCM, and Serial I\/O protocols. This wide protocol range covers most industrial communication requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat serial standards are available on each port?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEach port independently supports RS-232, RS-422, and RS-485 standards. This flexibility allows mixed interface types within the same module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is the isolation rating between ports?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe module provides \u003cspan style=\"color: #d9534f;\"\u003e500 VDC continuous isolation\u003c\/span\u003e between all communication ports. This high isolation level protects against ground loops and electrical noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHow many modules can I install in one rack?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou can install up to \u003cspan style=\"color: #007bff;\"\u003esix IC695CMM004 modules\u003c\/span\u003e in a single rack. This provides extensive serial communication capacity for complex systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical specifications and purchasing information, contact our sales team: \u003cstrong\u003e\u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139247005857,"sku":"IC695CMM004","price":206.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC695CMM004-2.jpg?v=1763017688","url":"https:\/\/www.autonexcontrol.com\/uk\/products\/communication-module-ge-fanuc-ic695cmm004","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}