{"title":"HIMA","description":"HIMA provides safety controllers and I\/O modules for industrial automation systems, enabling integration with sensors and other devices. Their solutions ensure functional safety, reliable operation, and long-lasting performance, supported by expert technical guidance for complex automation projects.","products":[{"product_id":"f3237-analog-input-module-hima","title":"F3237 Analog Input Module HIMA","description":"\u003ch2\u003e\n\u003cstrong\u003eF3237 Safety Input Module - Reliable Safety Monitoring\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0 Signal Range: 0.35 ≤ IE ≤ 1.2 mA\u003c\/li\u003e\n\u003cli\u003e1 Signal Range: 2.1 ≤ IE ≤ 6.0 mA\u003c\/li\u003e\n\u003cli\u003eWire Break Detection: ≤ 0.28 mA\u003c\/li\u003e\n\u003cli\u003eShort Circuit Detection: ≥ 6.5 mA\u003c\/li\u003e\n\u003cli\u003eLine Impedance: ≤ 50 Ohm per DIN 19234\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 5V = 90 mA; 24V = 170 mA\u003c\/li\u003e\n\u003cli\u003eMaximum Line Length: 1000 meters (∅ = 0.5 mm²)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSelf-Test Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch on\/off capability verification\u003c\/li\u003e\n\u003cli\u003eCrosstalk testing between input circuits\u003c\/li\u003e\n\u003cli\u003eInput filter functionality validation\u003c\/li\u003e\n\u003cli\u003eComplete module function testing\u003c\/li\u003e\n\u003cli\u003eSensor line short-circuit monitoring\u003c\/li\u003e\n\u003cli\u003eWire break detection continuous checking\u003c\/li\u003e\n\u003cli\u003eWalking 0 test for circuit isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNAMUR proximity switches per DIN 19234\u003c\/li\u003e\n\u003cli\u003eResistor-wired safety sensors\u003c\/li\u003e\n\u003cli\u003eSafety-related proximity switches\u003c\/li\u003e\n\u003cli\u003eCompatible with P\u0026amp;F NJ5-30GK-S1N with modification\u003c\/li\u003e\n\u003cli\u003eTwo-wire and three-wire sensor support\u003c\/li\u003e\n\u003cli\u003eIntrinsic safety sensor capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRequirement classes AK 1 through AK 6\u003c\/li\u003e\n\u003cli\u003eDIN 19234 NAMUR standard compliance\u003c\/li\u003e\n\u003cli\u003eFail-safe circuit compatibility\u003c\/li\u003e\n\u003cli\u003eSafety integrity level validation\u003c\/li\u003e\n\u003cli\u003eIndustrial safety standards meeting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat safety classes does the F 3237 support?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eF 3237\u003c\/strong\u003e meets requirement classes AK 1 through AK 6 for safety applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many input channels does this module provide?\u003c\/strong\u003e\u003cbr\u003eIt offers 8 safety-related input channels for sensor connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat types of sensors are compatible?\u003c\/strong\u003e\u003cbr\u003eIt supports NAMUR, resistor-wired, and safety proximity switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the response time of the module?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eF 3237\u003c\/strong\u003e has approximately 10ms switching time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it monitor for wiring faults?\u003c\/strong\u003e\u003cbr\u003eYes, it continuously monitors for short-circuits and wire breaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAre these modules brand new and original?\u003c\/strong\u003e\u003cbr\u003eWe supply \u003cstrong\u003ebrand new original\u003c\/strong\u003e modules with complete documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your shipping time and policy?\u003c\/strong\u003e\u003cbr\u003eWe process orders within 5 business days with 30-day returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich shipping carriers do you use?\u003c\/strong\u003e\u003cbr\u003eWe ship worldwide using DHL, FedEx, and UPS reliable services.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e \u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45232970530977,"sku":"F3237","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/F3237_1.jpg?v=1761104804"},{"product_id":"f7126-power-supply-module-hima","title":"F7126 Power supply module HIMA","description":"\u003ch2\u003e\u003cstrong\u003eF7126 Power Supply Module - Reliable DC\/DC Conversion\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e10A output current\u003c\/span\u003e capacity for demanding automation systems\u003c\/li\u003e\n\u003cli\u003eSafe isolation between input and output circuits\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection and current limitation\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof output for system protection\u003c\/li\u003e\n\u003cli\u003eAdjustable output voltage with test socket access\u003c\/li\u003e\n\u003cli\u003eHigh efficiency rate for reduced power consumption\u003c\/li\u003e\n\u003cli\u003eSuitable for redundant power supply configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOutput Voltage:\u003c\/span\u003e 5V DC ±0.5V adjustable\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOutput Current:\u003c\/span\u003e 10A maximum continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eFactory Setting:\u003c\/span\u003e 5.4V DC ±0.025V default\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCurrent Limiting:\u003c\/span\u003e Approximately 13A maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOvervoltage Protection:\u003c\/span\u003e 6.5V ±0.5V trigger point\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 20.4V to 28.8V DC\u003c\/li\u003e\n\u003cli\u003eRipple Content: \u0026lt; 15% on input voltage\u003c\/li\u003e\n\u003cli\u003ePrimary Fuse: 6.3A slow-blow type\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjustment: Continuous without steps\u003c\/li\u003e\n\u003cli\u003eEfficiency Rate: ≥ 77% typical operation\u003c\/li\u003e\n\u003cli\u003eInterference Limit: Class B per VDE 0871\/0877\u003c\/li\u003e\n\u003cli\u003eIsolation: Safe separation input to output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical and Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpace Requirement: 8 TE module width\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: PES H51q automation systems\u003c\/li\u003e\n\u003cli\u003eFront Panel Features: Test socket and adjustment potentiometer\u003c\/li\u003e\n\u003cli\u003eMounting: Standard rail or panel mounting\u003c\/li\u003e\n\u003cli\u003eCooling: Natural convection, no fan required\u003c\/li\u003e\n\u003cli\u003eConnection: Screw terminal blocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Short-Circuit Protection: Automatic current limiting\u003c\/li\u003e\n\u003cli\u003eOvervoltage Protection: 6.5V cutoff with ±0.5V tolerance\u003c\/li\u003e\n\u003cli\u003eCurrent Limitation: 13A maximum output current\u003c\/li\u003e\n\u003cli\u003eInput Protection: 6.3A primary fuse safety\u003c\/li\u003e\n\u003cli\u003eReverse Polarity Protection: Input circuit protection\u003c\/li\u003e\n\u003cli\u003eThermal Protection: Over-temperature shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRedundant Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eParallel Operation: Supported with voltage matching\u003c\/li\u003e\n\u003cli\u003eVoltage Tolerance: Maximum 0.025V difference between units\u003c\/li\u003e\n\u003cli\u003eLoad Balancing: Prevents unbalanced current sharing\u003c\/li\u003e\n\u003cli\u003eSystem Reliability: Enhanced through redundancy\u003c\/li\u003e\n\u003cli\u003eCritical Applications: Suitable for fail-safe systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: Standard industrial range\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: Industrial environment compatible\u003c\/li\u003e\n\u003cli\u003eHumidity Range: Standard industrial levels\u003c\/li\u003e\n\u003cli\u003eVibration Resistance: Industrial equipment rating\u003c\/li\u003e\n\u003cli\u003eEMC Compliance: VDE 0871\/0877 Class B\u003c\/li\u003e\n\u003cli\u003eSafety Standards: Industrial power supply compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e \u003cu\u003esales@nex-auto.com\u003c\/u\u003e\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45232971153569,"sku":"F7126","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/F7126_2.jpg?v=1761105235"},{"product_id":"hima-f8650e-safety-system-module-cpu","title":"HIMA F8650E Safety System Module CPU","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8650E Central Safety CPU Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #d35400;\"\u003eF8650E\u003c\/strong\u003e is the central processing unit for the \u003cstrong\u003eHIMA F8650 safety system\u003c\/strong\u003e. It is a dual-processor, fault-tolerant module designed for the highest safety integrity level (SIL) applications in process and machinery protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore System Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e F8650E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Central Safety System Module (CPU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArchitecture:\u003c\/strong\u003e Dual, clock-synchronized microprocessors (2oo2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor:\u003c\/strong\u003e Intel 386EX, 32-bit (x2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClock Frequency:\u003c\/strong\u003e 25 MHz per CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMemory Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating System Memory:\u003c\/strong\u003e Flash-EPROM, 1 MB (per CPU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Program Memory:\u003c\/strong\u003e Flash-EPROM, 1 MB (per CPU)*\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Memory:\u003c\/strong\u003e SRAM, 1 MB (per CPU)*\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e*Note: Actual usable capacity depends on the operating system version.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Power Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power (Backplane):\u003c\/strong\u003e 5 V \/ 2 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Output (Watchdog):\u003c\/strong\u003e 24 V DC, loadable up to 500 mA, short-circuit proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption (24V Line):\u003c\/strong\u003e Approximately 500 mA (Module), 2000 mA (System typical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication \u0026amp; Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Interfaces:\u003c\/strong\u003e 2 x RS-485 (electrically isolated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Display:\u003c\/strong\u003e 4-digit matrix display for status and fault information\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirement:\u003c\/strong\u003e 8 Subrack Units (SU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Watchdog:\u003c\/strong\u003e Integrated safety-related shutdown circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModule Features \u0026amp; Safety Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-channel (2oo2) architecture with synchronized processors ensures continuous comparison for fault detection.\u003c\/li\u003e\n\u003cli\u003eDedicated safety watchdog provides a 24V, 500mA output to safely de-energize external circuits upon a detected fault.\u003c\/li\u003e\n\u003cli\u003eIsolated RS-485 interfaces enable communication with other safety controllers, HMI, or engineering stations.\u003c\/li\u003e\n\u003cli\u003eThe front-panel 4-digit display provides quick access to diagnostic codes and system status.\u003c\/li\u003e\n\u003cli\u003eDesigned for use in safety instrumented systems (SIS) requiring certification up to SIL 3 (IEC 61508) or AK 6 (DIN V 19250).\u003c\/li\u003e\n\u003cli\u003eModular design plugs into a F8650 subrack as the central controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown (ESD) systems for oil \u0026amp; gas platforms and pipelines.\u003c\/li\u003e\n\u003cli\u003eFire and Gas (F\u0026amp;G) detection and mitigation systems.\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS) and turbine control.\u003c\/li\u003e\n\u003cli\u003eHigh-integrity machinery protection in chemical and pharmaceutical plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor system configuration or to order the \u003cstrong\u003eHIMA F8650E\u003c\/strong\u003e safety CPU, contact our safety systems specialists.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@nex-auto.com\"\u003e\u003cstrong\u003esales@nex-auto.com\u003c\/strong\u003e\u003c\/a\u003e or WhatsApp \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e\u003cstrong\u003e+86 153 9242 9628\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003e\u003cstrong\u003eNexAuto Technology Limited\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e© 2026 \u003ca href=\"https:\/\/www.autonexcontrol.com\/\"\u003e\u003cstrong\u003eAutoNex Controls Limited\u003c\/strong\u003e\u003c\/a\u003e. All rights reserved.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45627438530721,"sku":"F8650E","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/F8650E_1.jpg?v=1767772006"},{"product_id":"hima-f8650x-central-safety-module-sil-3","title":"HIMA F8650X Central Safety Module SIL 3","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8650X Central Safety Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #d35400;\"\u003eF8650X\u003c\/strong\u003e is the core processing module for the \u003cstrong\u003eHIMA PES (Programmable Electronic System) H51q series\u003c\/strong\u003e. It is a safety-certified controller designed for high-integrity applications up to SIL 3 according to IEC 61508.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore System Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e F8650X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Central Safety Module (CPU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Level:\u003c\/strong\u003e Up to SIL 3 (IEC 61508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor:\u003c\/strong\u003e Intel 386EX, 32-bit (Dual, synchronized)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClock Frequency:\u003c\/strong\u003e 25 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Data (Backplane):\u003c\/strong\u003e 5 V \/ 2 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirement:\u003c\/strong\u003e 8 Subrack Units (SU)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMemory Configuration (per CPU)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating System Memory:\u003c\/strong\u003e Flash-EPROM, 1 MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Program Memory:\u003c\/strong\u003e Flash-EPROM, 1 MB *\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Memory:\u003c\/strong\u003e SRAM, 1 MB *\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e* Note: Usable capacity depends on the operating system version.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInterfaces \u0026amp; Safety Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e 2 x RS-485 (electrically isolated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-485 Pinout (9-pin):\u003c\/strong\u003e\n\u003cul style=\"margin-top: 5px; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePins 3, 8:\u003c\/strong\u003e RxD\/TxD Data Lines (A, B)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 5:\u003c\/strong\u003e Data Ground (DGND)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePins 4, 9:\u003c\/strong\u003e Control Signals (CNTR-A, CNTR-B)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePins 2, 6:\u003c\/strong\u003e 5V Power (RP, VP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Watchdog Output:\u003c\/strong\u003e 24 V DC, loadable up to 500 mA, short-circuit proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Display:\u003c\/strong\u003e 4-digit alphanumeric matrix display with configurable information\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic LEDs:\u003c\/strong\u003e Two LEDs for CPU and I\/O error indication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Switches:\u003c\/strong\u003e Toggle switches for detailed error info; ACK button to reset errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication \u0026amp; Advanced Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWorks with communication module \u003cstrong\u003eF8627X\u003c\/strong\u003e for Ethernet connectivity (ELOP II TCP, safeethernet, Modbus TCP).\u003c\/li\u003e\n\u003cli\u003eSupports \u003cstrong\u003eSelf-education\u003c\/strong\u003e feature (from OS BS41q\/51q V7.0-8) for automatic configuration.\u003c\/li\u003e\n\u003cli\u003eSupports \u003cstrong\u003eELOP II TCP\u003c\/strong\u003e protocol for high-speed, safe communication.\u003c\/li\u003e\n\u003cli\u003eCritical for system upgrades: Replacing an older F8650 with an F8650X requires updating the \u003cstrong\u003efan cooling concept\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMaintenance \u0026amp; Battery Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuffer Battery Lifespan:\u003c\/strong\u003e\n\u003cul style=\"margin-top: 5px; padding-left: 20px;\"\u003e\n\u003cli\u003e1000 days at 25°C\u003c\/li\u003e\n\u003cli\u003e200 days at 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Replacement:\u003c\/strong\u003e Recommended every 6 years maximum, or within 3 months if BATI warning appears.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Type:\u003c\/strong\u003e Lithium CR 2477N (HIMA P\/N 44 0000018)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant Check:\u003c\/strong\u003e Verify bus station number and transmission rate settings on switch S1 during startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD) in oil \u0026amp; gas and chemical plants.\u003c\/li\u003e\n\u003cli\u003eFire \u0026amp; Gas (F\u0026amp;G) protection systems.\u003c\/li\u003e\n\u003cli\u003eTurbine and compressor control.\u003c\/li\u003e\n\u003cli\u003eRailway interlocking and process automation safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor system upgrades or to order the \u003cstrong\u003eHIMA F8650X\u003c\/strong\u003e central module, contact our safety systems experts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e Email \u003ca href=\"mailto:sales@nex-auto.com\"\u003e\u003cstrong\u003esales@nex-auto.com\u003c\/strong\u003e\u003c\/a\u003e or WhatsApp \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e\u003cstrong\u003e+86 153 9242 9628\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003e\u003cstrong\u003eNexAuto Technology Limited\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e© 2026 \u003ca href=\"https:\/\/www.autonexcontrol.com\/\"\u003e\u003cstrong\u003eAutoNex Controls Limited\u003c\/strong\u003e\u003c\/a\u003e. All rights reserved.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45627442200737,"sku":"F8650X","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/F8650X_1.jpg?v=1767772090"},{"product_id":"hima-f8627x-communication-module-fast-ethernet-modbus-tcp","title":"HIMA F8627X Communication Module – Fast Ethernet Modbus TCP","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8627X Communication Module – Modbus TCP and Safeethernet in One Unit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eF8627X\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Fast Ethernet Communication Module, Modbus TCP Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e 100 Base-T, RJ45 connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e 19-inch module, 3 height units (3 x 44.45 mm), 4 width units (4 x 5.08 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e Safeethernet, Modbus TCP, OPC DA, OPC A\u0026amp;E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e ELOP II via Ethernet (from V4.1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Mono or redundant safeethernet configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification Standards:\u003c\/strong\u003e IEC 61131-2, EN 61000-6, EN 50081-2, EN 50082-2, IEEE 802.3, EN 50170\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Complies with EN 61000-6 for industrial EMI and immunity\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003eIntegrated OPC A\u0026amp;E Support:\u003c\/strong\u003e\u003c\/span\u003e Delivers alarms and events via Ethernet without extra hardware\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003eUnified Network Architecture:\u003c\/strong\u003e\u003c\/span\u003e Runs safety and standard communication on the same bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatible CPU Models\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF8650X\u003c\/strong\u003e \/ \u003cstrong\u003eF8652X\u003c\/strong\u003e – Safe CPUs for H51q and H41q systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF8651X\u003c\/strong\u003e \/ \u003cstrong\u003eF8653X\u003c\/strong\u003e – Non-safe CPUs for H51q and H41q systems\u003c\/li\u003e\n\u003cli\u003eWorks alongside existing \u003cstrong\u003eF8627\u003c\/strong\u003e and \u003cstrong\u003eF8628\u003c\/strong\u003e modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 19-inch rack, occupies 3 HU and 4 WU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions per unit:\u003c\/strong\u003e 44.45 mm per height unit, 5.08 mm per width unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Plug-and-play RJ45 for 100 Base-T networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant setup:\u003c\/strong\u003e Supports two \u003cstrong\u003eF8627X\u003c\/strong\u003e modules for high availability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x HIMA \u003cstrong\u003eF8627X\u003c\/strong\u003e communication module\u003c\/li\u003e\n\u003cli\u003e1 x product documentation leaflet\u003c\/li\u003e\n\u003cli\u003eAnti-static protective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInventory status:\u003c\/strong\u003e New original, in stock now\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch time:\u003c\/strong\u003e Within 5 working days\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCourier partners:\u003c\/strong\u003e FedEx, UPS, DHL express services\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturn policy:\u003c\/strong\u003e 30-day return window accepted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat protocols does the \u003cstrong\u003eF8627X\u003c\/strong\u003e support?\u003c\/strong\u003e\u003cbr\u003eIt supports safeethernet, Modbus TCP slave, OPC DA, and OPC A\u0026amp;E via HIMA OPC server.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I program the CPU through this \u003cstrong\u003eF8627X\u003c\/strong\u003e module?\u003c\/strong\u003e\u003cbr\u003eYes, ELOP II V4.1 and later versions support Ethernet programming directly via \u003cstrong\u003eF8627X\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this module backward compatible with older CPUs?\u003c\/strong\u003e\u003cbr\u003eIt works with new F8650X, F8652X, F8651X, and F8653X CPUs. Existing F8627 and F8628 remain available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the physical size of the \u003cstrong\u003eF8627X\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eIt is a 19-inch module with 3 height units and 4 width units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you ship internationally?\u003c\/strong\u003e\u003cbr\u003eYes, we ship worldwide via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the \u003cstrong\u003eF8627X\u003c\/strong\u003e new and original?\u003c\/strong\u003e\u003cbr\u003eYes, every \u003cstrong\u003eF8627X\u003c\/strong\u003e is brand new and factory-sealed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003cbr\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003eWhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45710873624737,"sku":"F8627X","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/F8627X.jpg?v=1770880474"},{"product_id":"hima-f8628x-communication-module-profibus-dp-slave","title":"HIMA F8628X Communication Module – Profibus DP Slave","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8628X Communication Module – Profibus DP Slave with Ethernet Programming\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eF8628X\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Profibus DP Slave Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldbus Interface:\u003c\/strong\u003e 9-pole SUB-D connector for Profibus DP slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Interface:\u003c\/strong\u003e 100 Base-T, RJ45 for ELOP II programming\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e 19-inch module, 3 height units (3 x 44.45 mm), 4 width units (4 x 5.08 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e ELOP II via Ethernet from V4.1 and later\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003eDual-Port Design:\u003c\/strong\u003e\u003c\/span\u003e Operates Profibus DP slave and Ethernet programming simultaneously\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification Standards:\u003c\/strong\u003e IEC 61131-2, EN 61000-6, EN 50081-2, EN 50082-2, IEEE 802.3, EN 50170\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Meets EN 61000-6 for industrial EMC and immunity\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003eDirect CPU Access:\u003c\/strong\u003e\u003c\/span\u003e Enables Ethernet-based engineering without removing the fieldbus connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat fieldbus protocol does the \u003cstrong\u003eF8628X\u003c\/strong\u003e support?\u003c\/strong\u003e\u003cbr\u003eIt supports Profibus DP slave via the 9-pin SUB-D interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I program the CPU through this \u003cstrong\u003eF8628X\u003c\/strong\u003e module?\u003c\/strong\u003e\u003cbr\u003eYes, ELOP II V4.1 and newer versions support Ethernet programming through the RJ45 port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the \u003cstrong\u003eF8628X\u003c\/strong\u003e work with older HIMA CPUs?\u003c\/strong\u003e\u003cbr\u003eIt is designed for F8650X, F8652X, F8651X, and F8653X CPUs. Existing F8627 and F8628 modules remain available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the physical dimensions of the \u003cstrong\u003eF8628X\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eIt uses a 19-inch form factor with 3 height units and 4 width units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use Profibus and Ethernet at the same time?\u003c\/strong\u003e\u003cbr\u003eYes, the module operates both interfaces independently and simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the \u003cstrong\u003eF8628X\u003c\/strong\u003e new and original?\u003c\/strong\u003e\u003cbr\u003eYes, every \u003cstrong\u003eF8628X\u003c\/strong\u003e is brand new and factory-sealed original HIMA product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat shipping methods do you offer?\u003c\/strong\u003e\u003cbr\u003eWe ship via FedEx, UPS, and DHL with tracking provided.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003cbr\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003eWhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45710874017953,"sku":"F8628X","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/F8628X-1.jpg?v=1770881123"},{"product_id":"f8621a-hima-coprocessor-module-10-mhz-384kb-ram","title":"F8621A HIMA Coprocessor Module – 10 MHz 384KB RAM","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8621A Coprocessor Module – Dedicated Processing for PES H51q Systems\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eF8621A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Coprocessor Module for PES H51q\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor:\u003c\/strong\u003e Hitachi HD64180, 10 MHz clock frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 384 kbyte static CMOS-RAM and EPROM on 2 ICs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAM buffering:\u003c\/strong\u003e Battery-backed via HIMA \u003cstrong\u003eF7131\u003c\/strong\u003e power supply monitoring module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Port RAM:\u003c\/strong\u003e High-speed memory access to the second central module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating system:\u003c\/strong\u003e EPROM firmware for PLC master project execution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 5 V DC, 360 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace requirement:\u003c\/strong\u003e 4 TE (4 width units)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003eGalvanically isolated RS 485:\u003c\/strong\u003e\u003c\/span\u003e Two half-duplex channels with independent communication processors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud rates:\u003c\/strong\u003e 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 bps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate configuration:\u003c\/strong\u003e Software selectable or DIP switch takeover from CU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRS 485 Interface Pin Allocation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 1:\u003c\/strong\u003e Not used\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 2:\u003c\/strong\u003e RP, 5 V decoupled by diodes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 3 (A\/A):\u003c\/strong\u003e RxD\/TxD-A, Receive\/Transmit-Data-A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 4:\u003c\/strong\u003e CNTR-A, Control signal A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 5 (C\/C):\u003c\/strong\u003e DGND, Data Ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 6:\u003c\/strong\u003e VP, 5 V positive pole of power supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 7:\u003c\/strong\u003e Not used\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 8 (B\/B):\u003c\/strong\u003e RxD\/TxD-B, Receive\/Transmit-Data-B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin 9:\u003c\/strong\u003e CNTR-B, Control signal B\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Processing Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003eDual communication processors:\u003c\/strong\u003e\u003c\/span\u003e Each RS 485 interface has its own dedicated communication processor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud rate flexibility:\u003c\/strong\u003e Software configurable or inherits CU DIP switch settings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum transmission speed:\u003c\/strong\u003e Up to 57600 bps on both channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation:\u003c\/strong\u003e Protects against ground loops and voltage transients\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Port RAM interface:\u003c\/strong\u003e Connects directly to Bus 1 for fast data exchange\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaster project storage:\u003c\/strong\u003e RAM retains PLC project via external battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat CPU does the \u003cstrong\u003eF8621A\u003c\/strong\u003e use?\u003c\/strong\u003e\u003cbr\u003eIt uses the Hitachi HD64180 microprocessor running at 10 MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow much memory does the \u003cstrong\u003eF8621A\u003c\/strong\u003e have?\u003c\/strong\u003e\u003cbr\u003eIt contains 384 kbyte static CMOS-RAM and EPROM distributed across two ICs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is the RAM powered during a power loss?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eF8621A\u003c\/strong\u003e relies on the \u003cstrong\u003eF7131\u003c\/strong\u003e power supply monitoring module for battery buffering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat baud rates does the RS 485 support?\u003c\/strong\u003e\u003cbr\u003eIt supports 300 to 57600 bps including 9600, 19200, 38400, and 57600 bps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I set the baud rate manually?\u003c\/strong\u003e\u003cbr\u003eYes, software can set the rate or you can take over values from the CU DIP switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the \u003cstrong\u003eF8621A\u003c\/strong\u003e compatible with H41q systems?\u003c\/strong\u003e\u003cbr\u003eNo, this module is specifically designed for PES H51q systems only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the physical width of the \u003cstrong\u003eF8621A\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eIt occupies 4 TE, equivalent to 4 width units at 5.08 mm each.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this module new and original?\u003c\/strong\u003e\u003cbr\u003eYes, every \u003cstrong\u003eF8621A\u003c\/strong\u003e is brand new and factory-sealed HIMA product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003cbr\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003eWhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45710879883425,"sku":"F8621A","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/F8621A.jpg?v=1770881695"},{"product_id":"f8652x-hima-safety-related-cpu-dual-386ex-processors","title":"F8652X HIMA Safety-Related CPU – Dual 386EX Processors","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8652X Safety-Related CPU – Dual-Processor Redundancy with Integrated Diagnostics\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eF8652X\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder Code:\u003c\/strong\u003e 984865265\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Safety-related CPU for H51q and H41q systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor:\u003c\/strong\u003e 2 x Intel 386EX, 32-bit, 25 MHz clock frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory per microprocessor:\u003c\/strong\u003e 5 ICs each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating system:\u003c\/strong\u003e Flash-EPROM, 1 MByte\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser program:\u003c\/strong\u003e Flash-EPROM, 512 kByte\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData store:\u003c\/strong\u003e sRAM, 256 kByte\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfaces:\u003c\/strong\u003e 2 serial RS 485 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003eFail-safe watchdog:\u003c\/strong\u003e\u003c\/span\u003e 24 V DC output, loadable up to 500 mA, short circuit proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic display:\u003c\/strong\u003e 4-digit alphanumeric matrix display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e 2 PCBs European standard + 1 PCB for diagnostic display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace requirements:\u003c\/strong\u003e 8 TE (8 width units)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating data:\u003c\/strong\u003e 5 V DC, 2000 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStart-Up and Maintenance Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery backup lifetime without power:\u003c\/strong\u003e 2500 days at TA = 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery backup at elevated temperature:\u003c\/strong\u003e 100 days at TA = 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended battery change interval:\u003c\/strong\u003e Every 4 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery type:\u003c\/strong\u003e Lithium, CR 2477N, HIMA part number 44 0000018\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus station configuration:\u003c\/strong\u003e Verify bus station number and transmission rate on switch S1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat processors does the \u003cstrong\u003eF8652X\u003c\/strong\u003e use?\u003c\/strong\u003e\u003cbr\u003eIt uses two independent Intel 386EX 32-bit microprocessors running at 25 MHz each.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow much memory does the \u003cstrong\u003eF8652X\u003c\/strong\u003e have?\u003c\/strong\u003e\u003cbr\u003eEach processor has 1MB Flash-EPROM for OS, 512KB Flash-EPROM for user program, and 256KB sRAM for data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the purpose of the 4-digit display?\u003c\/strong\u003e\u003cbr\u003eIt shows alphanumeric diagnostic information and system status with requestable detailed views.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow long does the battery last without power?\u003c\/strong\u003e\u003cbr\u003e2500 days at 25°C and 100 days at 60°C. HIMA recommends replacement every 4 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat battery type does the \u003cstrong\u003eF8652X\u003c\/strong\u003e require?\u003c\/strong\u003e\u003cbr\u003eIt uses lithium battery type CR 2477N, HIMA part number 44 0000018.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the physical width of this CPU module?\u003c\/strong\u003e\u003cbr\u003eIt occupies 8 TE, equivalent to 8 width units at 5.08 mm each.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the \u003cstrong\u003eF8652X\u003c\/strong\u003e work with H41q systems?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed for both H51q and H41q systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I configure the bus station number?\u003c\/strong\u003e\u003cbr\u003eUse switch S1 on the module to set the bus station number and transmission rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this module new and original?\u003c\/strong\u003e\u003cbr\u003eYes, every \u003cstrong\u003eF8652X\u003c\/strong\u003e is brand new and factory-sealed HIMA product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003cbr\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003eWhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45710882013345,"sku":"F8652X","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/F8652X-3.jpg?v=1770881934"},{"product_id":"hima-f7131-power-supply-monitor-buffer-batteries","title":"HIMA F7131 Power Supply Monitor – Buffer Batteries","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F7131 Power Supply Monitoring Module – Battery-Buffered Voltage Supervision for PES H51q\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eF7131\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Power supply monitoring with buffer batteries for PES H51q\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage monitoring:\u003c\/strong\u003e 5 V DC system voltage from up to 3 power supplies\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003eFront-panel indicators:\u003c\/strong\u003e\u003c\/span\u003e 3 LED displays for immediate power supply status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic interface:\u003c\/strong\u003e 3 test bits for \u003cstrong\u003eF8650\u003c\/strong\u003e or \u003cstrong\u003eF8651\u003c\/strong\u003e central modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional power supply monitoring:\u003c\/strong\u003e 3 x 24 V DC outputs (PS1 to PS3) for B9361 assembly kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace requirement:\u003c\/strong\u003e 4 TE (4 width units)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating data 5 V DC:\u003c\/strong\u003e 25 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating data 24 V DC:\u003c\/strong\u003e 20 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBattery Backup Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003eBattery change interval:\u003c\/strong\u003e\u003c\/span\u003e Recommended every 4 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery type:\u003c\/strong\u003e CR-1\/2 AA-CB, lithium\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHIMA part number:\u003c\/strong\u003e 44 0000016\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuffer function:\u003c\/strong\u003e Maintains RAM data on connected CPU modules during power failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible CPUs:\u003c\/strong\u003e \u003cstrong\u003eF8650\u003c\/strong\u003e and \u003cstrong\u003eF8651\u003c\/strong\u003e central modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the primary function of the \u003cstrong\u003eF7131\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eIt monitors 5 V system voltage from up to three power supplies and provides battery backup for CPU RAM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich CPU modules are compatible with the \u003cstrong\u003eF7131\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eIt works with HIMA \u003cstrong\u003eF8650\u003c\/strong\u003e and \u003cstrong\u003eF8651\u003c\/strong\u003e central modules for PES H51q systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many power supplies can this module monitor?\u003c\/strong\u003e\u003cbr\u003eIt monitors up to three redundant power supplies generating the 5 V system voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat battery does the \u003cstrong\u003eF7131\u003c\/strong\u003e require?\u003c\/strong\u003e\u003cbr\u003eIt uses CR-1\/2 AA-CB lithium battery, HIMA part number 44 0000016.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow often should I change the buffer battery?\u003c\/strong\u003e\u003cbr\u003eHIMA recommends battery replacement every four years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the \u003cstrong\u003eF7131\u003c\/strong\u003e provide diagnostic feedback to the CPU?\u003c\/strong\u003e\u003cbr\u003eYes, it provides three test bits readable by \u003cstrong\u003eF8650\u003c\/strong\u003e and \u003cstrong\u003eF8651\u003c\/strong\u003e for diagnostic display and user program use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the B9361 assembly kit?\u003c\/strong\u003e\u003cbr\u003eIt is an additional power supply assembly kit. The \u003cstrong\u003eF7131\u003c\/strong\u003e monitors its power supply modules via 24 V outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the physical width of the \u003cstrong\u003eF7131\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eIt occupies 4 TE, equivalent to 4 width units at 5.08 mm each.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this module new and original?\u003c\/strong\u003e\u003cbr\u003eYes, every \u003cstrong\u003eF7131\u003c\/strong\u003e is brand new and factory-sealed HIMA product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information\u003c\/strong\u003e\u003cbr\u003eInquiries: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003eWhatsApp: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePartner: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003eNexAuto Technology Limited\u003c\/a\u003e\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45710886240417,"sku":"F7131","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/F7131-2.jpg?v=1770882175"}],"url":"https:\/\/www.autonexcontrol.com\/uk\/collections\/hima.oembed?page=2","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}