{"product_id":"3500-61-03-01-bently-nevada-temp-monitor-recorder-output","title":"3500\/61-03-01 Bently Nevada Temp Monitor Recorder Output","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 3500\/61-03-01 Isolated Temperature Monitor with Recorder Outputs\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e03e2d;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e: Bently Nevada (Made in U.S.A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e03e2d;\"\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003e3500\/61-03-01\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e03e2d;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e: Temperature Monitors with Recorder Outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e03e2d;\"\u003e\u003cstrong\u003eI\/O Module Type\u003c\/strong\u003e\u003c\/span\u003e: 03 = TC Isolated I\/O Module with Internal Terminations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e03e2d;\"\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/span\u003e: 01 = CSA\/NRTL\/C (Class 1, Div 2).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications in a Tree Structure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Bently Nevada\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: \u003cstrong\u003e3500\/61-03-01\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuffix Information\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/61\u003c\/strong\u003e : Temperature Monitor with Recorder Outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-03\u003c\/strong\u003e : I\/O Module Type (TC Isolated I\/O Module \/ Internal Terminations)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e : Agency Approval (CSA\/NRTL\/C Class 1 Div 2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInput \u0026amp; Signal Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e: Accepts 1 to 6 RTD or TC transducer signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: 10 MΩ for each lead input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e03e2d;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003e3500\/60\u003c\/strong\u003e uses 7 watts nominal. \u003cstrong\u003e3500\/61\u003c\/strong\u003e uses 9 watts nominal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple (TC) Types \u0026amp; Ranges\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eType E: -100 °C to +1000 °C (-148 °F to +1832 °F).\u003c\/li\u003e\n\u003cli\u003eType J: -18 °C to +760 °C (+0 °F to +1400 °F).\u003c\/li\u003e\n\u003cli\u003eType K: -18 °C to +1370 °C (+0 °F to +2498 °F).\u003c\/li\u003e\n\u003cli\u003eType T: -160 °C to +400 °C (-256 °F to +752 °F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated TC Range Note\u003c\/strong\u003e: Type E range reduces to -60°C if ambient exceeds +35°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Types \u0026amp; Ranges (3-wire \u0026amp; 4-wire)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e100Ω Platinum (α=0.00385): -200°C to +850°C (recommended standard).\u003c\/li\u003e\n\u003cli\u003e100Ω Platinum (α=0.00392): -200°C to +700°C.\u003c\/li\u003e\n\u003cli\u003e120Ω Nickel: -80°C to +260°C.\u003c\/li\u003e\n\u003cli\u003e10Ω Copper: -100°C to +260°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIsolation \u0026amp; Output Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Isolation Voltage\u003c\/strong\u003e: 500 Vdc for isolated I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel to Channel Isolation\u003c\/strong\u003e: 250 Vdc for fault scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e: +4 to +20 mA proportional to full-scale values.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Compliance\u003c\/strong\u003e: 0 to +12 Vdc across a 0 to 600 Ω load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e03e2d;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e: 0.3662 µA per bit with ±0.15% error at room temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Panel LEDs\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eOK LED: Indicates proper monitor operation.\u003c\/li\u003e\n\u003cli\u003eTX\/RX LED: Shows communication with other 3500 rack modules.\u003c\/li\u003e\n\u003cli\u003eBypass LED: Indicates Bypass Mode activation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Current Source\u003c\/strong\u003e: 925 ±15 µA @ 25°C per transducer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAccuracy \u0026amp; Environmental Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy (Internal Termination Isolated \/ Standard Rack)\u003c\/strong\u003e: ±3 °C at 25 °C (±5.4 °F at 77 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy (External Termination Isolated \/ Bulkhead Rack)\u003c\/strong\u003e: ±1 °C at 25 °C (±1.8 °F at 77 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 Ω Copper RTD Accuracy\u003c\/strong\u003e: ±3 °C at 25 °C with 1°C resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e-30°C to +65°C for internal\/external termination I\/O modules.\u003c\/li\u003e\n\u003cli\u003e0°C to +65°C for internal barrier I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +85°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the \u003cstrong\u003e3500\/61-03-01\u003c\/strong\u003e brand new?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we only supply \u003cspan style=\"color: #e03e2d;\"\u003ebrand new original\u003c\/span\u003e units directly from authorized sources.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have this isolated monitor in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we keep \u003cstrong\u003e3500\/61-03-01\u003c\/strong\u003e in our warehouse for immediate shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does delivery take?\u003c\/strong\u003e\u003cbr\u003eA: We dispatch within 5 days. Express carriers deliver in 3-7 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which courier do you use?\u003c\/strong\u003e\u003cbr\u003eA: We normally use \u003cstrong\u003eDHL, FedEx, and UPS\u003c\/strong\u003e for reliable worldwide service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the isolation voltage for this module?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e3500\/61-03-01\u003c\/strong\u003e provides 500 Vdc system isolation and 250 Vdc channel-to-channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support \u003cspan style=\"color: #e03e2d;\"\u003e30-day returns\u003c\/span\u003e for items in original condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the monitor support Type K TC?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports Type K from -18°C to +1370°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Information: For inquiries, email \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e or call \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e (WhatsApp). Partner NexAuto Technology Limited: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46447024603297,"sku":"3500\/61-03-01","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/3500_61-03-01.jpg?v=1779269625","url":"https:\/\/www.autonexcontrol.com\/tr\/products\/3500-61-03-01-bently-nevada-temp-monitor-recorder-output","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}