{"product_id":"voltage-output-module-ge-fanuc-emerson-ic694mdl390","title":"Voltage Output Module GE Fanuc Emerson IC694MDL390","description":"\u003ch2\u003e\u003cb\u003eGE Fanuc IC694MDL390 Discrete Output Module - PACSystems RX3i\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eKey Electrical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eVoltage Range:\u003c\/b\u003e \u003cspan style=\"color: red;\"\u003e85-264 VAC\u003c\/span\u003e (50\/60 Hz operation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRated Voltage:\u003c\/b\u003e \u003cspan style=\"color: red;\"\u003e120\/240 VAC\u003c\/span\u003e standard industrial power\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOutput Points:\u003c\/b\u003e \u003cspan style=\"color: red;\"\u003e5\u003c\/span\u003e individually common circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOutput Current:\u003c\/b\u003e \u003cspan style=\"color: red;\"\u003e2 A\u003c\/span\u003e maximum per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInrush Current:\u003c\/b\u003e \u003cspan style=\"color: red;\"\u003e25 A\u003c\/span\u003e capability per cycle\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLeakage Current:\u003c\/b\u003e \u003cspan style=\"color: red;\"\u003e2 mA\u003c\/span\u003e maximum when off\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVoltage Drop:\u003c\/b\u003e \u003cspan style=\"color: red;\"\u003e1.5 V\u003c\/span\u003e maximum across outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eIsolation and Protection Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eLogic to Field Isolation:\u003c\/b\u003e \u003cspan style=\"color: red;\"\u003e250 VAC\u003c\/span\u003e continuous rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePoint to Point Isolation:\u003c\/b\u003e \u003cspan style=\"color: red;\"\u003e1500 VAC\u003c\/span\u003e for 1 minute withstand\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower Consumption:\u003c\/b\u003e \u003cspan style=\"color: red;\"\u003e315 mA\u003c\/span\u003e at 5V bus voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eResponse Time:\u003c\/b\u003e ON in \u003cspan style=\"color: red;\"\u003e1 ms\u003c\/span\u003e; OFF in half cycle\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAccuracy:\u003c\/b\u003e ±1% of nominal value across range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eEnvironmental Durability\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eOperating Temperature:\u003c\/b\u003e 0 to 60°C industrial range\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Temperature:\u003c\/b\u003e -40 to 85°C extreme conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHumidity Tolerance:\u003c\/b\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVibration Resistance:\u003c\/b\u003e 10-57 Hz, 0.05 mm peak amplitude\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShock Resistance:\u003c\/b\u003e 15 G for 11 ms duration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003eWhat is the maximum current per output on the IC694MDL390?\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eEach of the five outputs handles \u003cspan style=\"color: red;\"\u003e2 A\u003c\/span\u003e continuous current with \u003cspan style=\"color: red;\"\u003e25 A\u003c\/span\u003e inrush capability.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eWhat voltage ranges does this output module support?\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cb\u003eIC694MDL390\u003c\/b\u003e operates from \u003cspan style=\"color: red;\"\u003e85-264 VAC\u003c\/span\u003e with \u003cspan style=\"color: red;\"\u003e120\/240 VAC\u003c\/span\u003e rated voltage.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eHow many devices can I control with this module?\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eYou can control five separate devices or circuits with individual \u003cspan style=\"color: red;\"\u003e2 A\u003c\/span\u003e capacity each.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eWhat isolation protection does the module provide?\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eIt offers \u003cspan style=\"color: red;\"\u003e250 VAC\u003c\/span\u003e continuous logic-field isolation and \u003cspan style=\"color: red;\"\u003e1500 VAC\u003c\/span\u003e point-to-point protection.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eWhat is the operating temperature range?\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003eThe module performs reliably in temperatures from 0 to 60°C, suitable for most industrial applications.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45139289407649,"sku":"IC694MDL390","price":206.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/5390\/3265\/files\/IC694DSM314_c3ef8ac1-de79-447f-9145-9ca3dd757b9e.jpg?v=1758192712","url":"https:\/\/www.autonexcontrol.com\/th\/products\/voltage-output-module-ge-fanuc-emerson-ic694mdl390","provider":"AutoNex Controls Limited ","version":"1.0","type":"link"}